FIR04-00195
| FIR-Aging Inspection | 7/1/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | | PASS |
|
|
Talked to Jim Danes and he will check into this permit 7/1/2004 4:04:49 PM
|
FIR04-00301
| INSP-Alarm Testing | 6/30/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | A | PASS |
|
|
Rick, We would like to schedule an inspection for 7/1/04 in the morning if at all possible, if the morning won't work, early afternoon if at all possible. Please call me at the office, ###-####, or on my cell ###-####, as soon as you can, so that we can be sure to have our guys there on site. Thanks, Jason; Phone #: ###-#### Internet Inspection Request from: Jason Minnick
|
FIR04-00179
| INSP-Sprinkler Rough-in/Hydro | 6/30/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | A | PASS |
|
|
Contact: Mike Leiser - This is a hydro test, would like done around 11 am, please call Mike to confirm 7-1-04; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley Per Bill Alexander the new copper line under the bar canopy will not require sprinkler plan mofications; the semi-portable table canopies will not require sprinklers 7/1/2004 4:06:29 PM
|
BLD04-00924
| FIRE-Final Inspection | 6/30/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | A | PASS |
|
|
Brett; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
|
FIR03-00354
| INSP-Final Inspection | 6/30/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | A | PASS |
|
|
|
FIR04-00285
| INSP-Final Inspection | 6/30/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | A | CANC |
|
|
Wrong permit called in 7/1/2004 9:04:20 AM
|
FIR04-00355
| INSP-Final Inspection | 6/30/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | A | PASS |
|
|
|
FIR03-00144
| INSP-Final Inspection | 7/1/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | A | PASS |
|
|
|
BLD00-03428
| FIRE-Sprinkler Rough-in | 7/1/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | P | PART |
|
|
calvin; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Will need additional EQ's at expansion joint and at 4 inch line to walkway to concourse 7/2/2004 10:18:15 AM
|
FIR04-00233
| INSP-Final Inspection | 7/1/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | P | PASS |
|
|
The anti-freeze loop tamper completed 7/1/2004 4:07:06 PM
|
BLD04-00038
| FIRE-Final Inspection | 7/1/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | P | PASS |
|
|
Phase 2 (terrace) is completed; fire final okay for perm occupancy 7/1/2004 4:08:08 PM
|
FIR04-00275
| INSP-Final Inspection | 6/30/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | P | FAIL |
|
|
Mick; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes Need calc's for capacity of the complete dry system in basement; trip tested and got full stream at test orifice at 4 minutes and at 55 seconds water reached orifice but not a full steady stream 7/1/2004 4:10:29 PM
|
FIR04-00112
| INSP-Supply line flush | 7/1/2004 | 7/1/2004 | 7/1/2004 12:00:00 AM | P | PASS |
|
|
Mike; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes UG permit completed 7/1/2004 4:17:43 PM
|