Inspections for the day of: Thursday, July 1, 2004.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRick Jackson
TitleFIRE INSPECTOR
Phone #794-1981
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR04-00195 FIR-Aging Inspection7/1/20047/1/20047/1/2004 12:00:00 AM PASS
Talked to Jim Danes and he will check into this permit 7/1/2004 4:04:49 PM
FIR04-00301 INSP-Alarm Testing6/30/20047/1/20047/1/2004 12:00:00 AMAPASS
Rick, We would like to schedule an inspection for 7/1/04 in the morning if at all possible, if the morning won't work, early afternoon if at all possible. Please call me at the office, ###-####, or on my cell ###-####, as soon as you can, so that we can be sure to have our guys there on site. Thanks, Jason; Phone #: ###-#### Internet Inspection Request from: Jason Minnick
FIR04-00179 INSP-Sprinkler Rough-in/Hydro6/30/20047/1/20047/1/2004 12:00:00 AMAPASS
Contact: Mike Leiser - This is a hydro test, would like done around 11 am, please call Mike to confirm 7-1-04; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley Per Bill Alexander the new copper line under the bar canopy will not require sprinkler plan mofications; the semi-portable table canopies will not require sprinklers 7/1/2004 4:06:29 PM
BLD04-00924 FIRE-Final Inspection6/30/20047/1/20047/1/2004 12:00:00 AMAPASS
Brett; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
FIR03-00354 INSP-Final Inspection6/30/20047/1/20047/1/2004 12:00:00 AMAPASS
FIR04-00285 INSP-Final Inspection6/30/20047/1/20047/1/2004 12:00:00 AMACANC
Wrong permit called in 7/1/2004 9:04:20 AM
FIR04-00355 INSP-Final Inspection6/30/20047/1/20047/1/2004 12:00:00 AMAPASS
FIR03-00144 INSP-Final Inspection7/1/20047/1/20047/1/2004 12:00:00 AMAPASS
BLD00-03428 FIRE-Sprinkler Rough-in7/1/20047/1/20047/1/2004 12:00:00 AMPPART
calvin; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Will need additional EQ's at expansion joint and at 4 inch line to walkway to concourse 7/2/2004 10:18:15 AM
FIR04-00233 INSP-Final Inspection7/1/20047/1/20047/1/2004 12:00:00 AMPPASS
The anti-freeze loop tamper completed 7/1/2004 4:07:06 PM
BLD04-00038 FIRE-Final Inspection7/1/20047/1/20047/1/2004 12:00:00 AMPPASS
Phase 2 (terrace) is completed; fire final okay for perm occupancy 7/1/2004 4:08:08 PM
FIR04-00275 INSP-Final Inspection6/30/20047/1/20047/1/2004 12:00:00 AMPFAIL
Mick; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes Need calc's for capacity of the complete dry system in basement; trip tested and got full stream at test orifice at 4 minutes and at 55 seconds water reached orifice but not a full steady stream 7/1/2004 4:10:29 PM
FIR04-00112 INSP-Supply line flush7/1/20047/1/20047/1/2004 12:00:00 AMPPASS
Mike; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes UG permit completed 7/1/2004 4:17:43 PM