PLM08-01525
| Sprinkler (Final) | 7/1/2008 | 7/1/2008 | 7/1/2008 5:02:21 PM | P | FAIL |
|
|
use approved fittings at service tie in.
|
PLM08-01555
| Sprinkler (Final) | 6/30/2008 | 7/1/2008 | 7/1/2008 2:36:13 PM | P | FAIL |
|
|
Peter Phone #: ###-#### need approved fittings at water service tie in
|
PLM08-01553
| Sprinkler (Final) | 6/30/2008 | 7/1/2008 | 7/1/2008 2:22:43 PM | P | PASS |
|
|
Peter Phone #: ###-####
|
PLM08-01552
| Sprinkler (Final) | 6/30/2008 | 7/1/2008 | 7/1/2008 2:22:30 PM | P | PASS |
|
|
Peter Phone #: ###-####
|
PLM08-01554
| Sprinkler (Final) | 6/30/2008 | 7/1/2008 | 7/1/2008 2:22:13 PM | P | PASS |
|
|
Peter Phone #: ###-####
|
PLM08-01297
| Water and/or Sewer | 7/1/2008 | 7/1/2008 | 7/1/2008 2:04:55 PM | P | PART |
|
|
Scheduled by a contractor via Hello! on 7/1/2008 at 11:12:58 AM. Contact: ###-####. water service ok
|
PLM08-00652
| Final | 7/1/2008 | 7/1/2008 | 7/1/2008 1:27:31 PM | P | PASS |
|
|
final ok
|
MEC08-01899
| Rough-in | 6/30/2008 | 7/1/2008 | 7/1/2008 10:58:26 AM | A | PASS |
|
|
Contact Lemmon Construction for access. ###-#### Phone #: ###-#### Internet Inspection Request from: Frank Marturello ri 20# test ok, will need to update existing water heater flue by final.
|
MEC08-01863
| Final | 6/30/2008 | 7/1/2008 | 7/1/2008 10:10:27 AM | A | PASS |
|
|
michaelle Phone #: ###-#### ri ok
|
MEC08-01849
| Rough-in | 6/30/2008 | 7/1/2008 | 7/1/2008 9:37:45 AM | A | PASS |
|
|
gas and ri reinspect Phone #: ###-#### Internet Inspection Request from: LINDA DORN ri 20# test ok
|
PLM08-01525
| Final | 6/30/2008 | 7/1/2008 | 7/1/2008 9:10:25 AM | A | FAIL |
|
|
Deloris Phone #: ###-#### pump water from around connection to water service. shut off and drain valves must be 36" below grade. 160 PSI min. PEX service piping required between service connection and backflow preventer. test backflow preventer.
|
PLM07-02062
| Other | 7/1/2008 | 7/1/2008 | 7/1/2008 8:42:39 AM | A | PART |
|
|
-can wasah correction notice.- 1)PVB is not listed for back pressure. 2) An R.P. is required on the water supply to the can wash and hose reel due to a direct connection to the inlet side of a sewer connected trap below the flood level rim, degree of hazard(garbage can wash) and elevated piping downstream of the backflow preventer.
|
PLM08-00998
| Roof Drains | 6/30/2008 | 7/1/2008 | 6/30/2008 2:35:40 PM | A | PART |
|
|
Please call Tim with any questions ###-#### Phone #: ###-#### Internet Inspection Request from: Sonja Hankel
|
PLM08-00998
| Plumbing Rough-in | 6/30/2008 | 7/1/2008 | 6/30/2008 2:35:27 PM | A | PART |
|
|
Please call Tim with any questions ###-#### Phone #: ###-#### Internet Inspection Request from: Sonja Hankel
|