GCM14-00026
| GCM-Final | 7/1/2014 | 7/1/2014 | 7/1/2014 4:44:23 PM | P | PEND |
|
|
Doug ###-####..i have sent a conference to the structural inspector as this looks like 2 seperate residences with 2 kitchens, differerent access into units and 2 laundry facilities. the building permit says this is a single family dwelling.
|
MEC14-02559
| Rough-in | 7/1/2014 | 7/1/2014 | 7/1/2014 4:33:48 PM | P | FAIL |
|
|
Will Phone #: ###-####..need test on all flues..need a conference
|
MEC14-02559
| Pressure Test | 7/1/2014 | 7/1/2014 | 7/1/2014 4:32:00 PM | P | PASS |
|
|
Will Phone #: ###-####..60lb and 20lb test ok
|
MEC13-03579
| Final | 7/1/2014 | 7/1/2014 | 7/1/2014 4:31:14 PM | P | NH |
|
|
Have attempted to contact the customer, Jodie Hunt (###-####), through multiple lines of communication (phone disconnected, not responding to letters) to schedule this inspection but have been unable to reach her. Phone #: ###-#### >> Inspection requested via web by James Staley..mother will notify the daughter about the inspection
|
MEC14-02642
| Rough-in | 7/1/2014 | 7/1/2014 | 7/1/2014 4:30:20 PM | P | FAIL |
|
|
Oleg Phone #: ###-####..no manual j on site..need 1" clearance at w/h flue..unable to use a 30lb guage on furn flue (has to be a 10 or 15 lb guage and a 5lb test)
|
MEC14-02642
| Rough-in | 7/1/2014 | 7/1/2014 | 7/1/2014 4:28:19 PM | P | FAIL |
|
|
Oleg-Fireplace Phone #: ###-####..flue to be 2' from side of house and 18" from overhang
|
MEC14-02687
| Final | 7/1/2014 | 7/1/2014 | 7/1/2014 4:25:59 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by April Thomas
|
MEC14-02154
| Final | 6/30/2014 | 7/1/2014 | 7/1/2014 4:14:06 PM | P | PASS |
|
|
Please call Chad B4 ariival to arrange access. Phone #: ###-#### >> Inspection requested via web by Lisa Whitney
|
MEC14-02642
| Pressure Test | 7/1/2014 | 7/1/2014 | 7/1/2014 2:55:21 PM | P | NH |
|
|
Have attempted to contact the customer, Jodie Hunt (###-####), through multiple lines of communication (phone disconnected, not responding to letters) to schedule this inspection but have been unable to reach her. Phone #: ###-#### >> Inspection requested via web by James Staley..mother will contact the daughter
|
MEC14-02686
| Conference | 7/1/2014 | 7/1/2014 | 7/1/2014 1:20:18 PM | P | PASS |
|
|
INSTALLER SAM ###-#### Phone #: ###-#### >> Inspection requested via web by Dustin Rich
|
GCM14-00160
| GCM-Rough In & Pressure Test | 6/30/2014 | 7/1/2014 | 7/1/2014 1:14:27 PM | P | PART |
|
|
Air Care ###-####..need access to f/p specs..fir wall at dryer vent..coil doesn't match manual j..complete fresh air..20lb gas ok
|
GCM13-00289
| GCM-Pressure Test | 6/30/2014 | 7/1/2014 | 7/1/2014 11:14:38 AM | A | PASS |
|
|
Mel ###-####..60lb test from meter to incinerator ok
|
MEC14-02686
| Final | 7/1/2014 | 7/1/2014 | 7/1/2014 10:49:56 AM | A | PASS |
|
|
dustin ###-####
|
MEC13-02849
| Final | 6/30/2014 | 7/1/2014 | 7/1/2014 10:48:12 AM | A | NH |
|
|
A-1 can''t get the customer to respond for inspection please note card per Bill Vandergrift..I LEFT ANOTHER NOTE ON THE DOOR
|
MEC14-02651
| Final | 6/30/2014 | 7/1/2014 | 7/1/2014 10:39:06 AM | A | PASS |
|
|
This is a Final Inspection scheduled for the AM. Phone #: ###-#### >> Inspection requested via web by Mary LaFayette
|
MEC13-03126
| Final | 6/30/2014 | 7/1/2014 | 7/1/2014 10:00:22 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dustin Rich
|
MEC14-02674
| Conference | 6/30/2014 | 7/1/2014 | 7/1/2014 7:30:46 AM | A | CANC |
|
|
call ahead for access, Larry at ###-#### >> Inspection requested via web by Mike Almanza Inspection cancelled from web by: Mike Almanza
|