ELE19-01748
| Final | 6/30/2019 | 7/1/2019 | 7/1/2019 3:32:17 PM | P | NR |
|
|
Mike is the onsite contact. Late afternoon around 4:30 if at all possible Phone #: ###-#### Inspection requested via web by Matt Sovic... GFCI protection not complete, L/Os not installed on 240V 3 phase equipment, demo of temp lighting, wiring thru grid to outlets above grid needs addressed, panel labelling completed
|
ELE19-01748
| Electrical Rough-In | 7/1/2019 | 7/1/2019 | 7/1/2019 3:27:35 PM | P | PASS |
|
|
Mike is the onsite contact. Late afternoon around 4:30 if at all possible Phone #: ###-#### Inspection requested via web by Matt Sovic... grid ok to cover
|
ELE19-02449
| Final | 7/1/2019 | 7/1/2019 | 7/1/2019 3:11:37 PM | P | PASS |
|
|
Chad Vanorden is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce.. all work on surface of building new disconnects and piping to 2 new units job complete...ok to final
|
ELE18-04746
| Electrical Rough-In | 7/1/2019 | 7/1/2019 | 7/1/2019 3:00:08 PM | P | PASS |
|
|
We need a partial ceiling grid inspection. Please call 30 minutes ahead if possible. The contact is Ryan at ###-#### Phone #: ###-#### Inspection requested via web by Kerri Hamilton.. ok to cover...sections marked on plans
|
ELE19-01516
| Final | 7/1/2019 | 7/1/2019 | 7/1/2019 2:26:19 PM | P | FAIL |
|
|
call for code Phone #: ###-#### Inspection requested via web by Robert Murray... 1..outlets need to be installed completely spare bedroom 2..2ft wall space needs outlet installed..mst bed 3..panel missing screws x 2
|
ELE19-02448
| Final | 7/1/2019 | 7/1/2019 | 7/1/2019 1:50:38 PM | P | PASS |
|
|
brent Phone #: ###-####...ok to final
|
ELE19-02419
| Electrical Rough-In | 7/1/2019 | 7/1/2019 | 7/1/2019 1:25:21 PM | P | PASS |
|
|
Floor Box Rough In Inspection - Please contact Butch @ ###-####
Phone #: ###-#### Inspection requested via web by JENNY EMEL... underground ok to cover
|
ELE19-01765
| Final | 7/1/2019 | 7/1/2019 | 7/1/2019 12:42:40 PM | P | PASS |
|
|
Jason is contact person Phone #: ###-#### Inspection requested via web by Sherry Allen... disconnect within GFCI breakers installed, 2 x 20A circuits, #12 wire...job complete..ok to final
|
ELE19-02447
| Electrical Rough-In | 7/1/2019 | 7/1/2019 | 7/1/2019 12:23:03 PM | P | PASS |
|
|
listing inspection for solar equipment; crew on site Phone #: ###-#### Inspection requested via web by Ryan King... UL listed equipment line side splice
|
ELE19-02439
| Electrical Rough-In | 7/1/2019 | 7/1/2019 | 7/1/2019 12:06:53 PM | P | PASS |
|
|
lock box code is 4821 if I happen to not be there the work is behind plastic to your right if your after 2:00 they will be open which will be not a problem for you to inspect. Phone #: ###-#### Inspection requested via web by Jay Symonds... new kitchen area rough in ok to cover
|
ELE19-00811
| Final | 6/28/2019 | 7/1/2019 | 7/1/2019 9:56:33 AM | A | FAIL |
|
|
garage code 2019 Phone #: ###-#### Inspection requested via web by Darryn Coburn.. 1) flex room/unfinished room...outlets shall have GFCI protection 2) outlets shall be completed...no plates...bedrooms x 2 3) unable to inspect outlets...Mst bedroom...furniture installed in front of outlets Boise City ordinance
|
ELE19-00914
| Final | 6/28/2019 | 7/1/2019 | 7/1/2019 9:53:47 AM | A | PASS |
|
|
garage code 2019 Phone #: ###-#### Inspection requested via web by Darryn Coburn.. ok to final
|
ELE19-02285
| Permanent Service | 7/1/2019 | 7/1/2019 | 7/1/2019 9:41:51 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot Inspection cancelled from web by: Barbara Szurgot
|
ELE19-01545
| Final | 6/30/2019 | 7/1/2019 | 7/1/2019 9:00:09 AM | A | FAIL |
|
|
garage code 3484 Phone #: ###-#### Inspection requested via web by Neal Rumsey.. 1) NMB shall be protected from physical damage...kitchen hood 2) back patio light not working 3) back patio weather proof outlet has no power
|
ELE19-01085
| Final | 6/28/2019 | 7/1/2019 | 7/1/2019 8:25:59 AM | A | PASS |
|
|
8 Plex Phone #: ###-#### Inspection requested via web by Kevin Burke... correction made..ok to final
|
ELE19-02419
| Electrical Rough-In | 6/28/2019 | 7/1/2019 | 7/1/2019 7:03:00 AM | A | CANC |
|
|
Floor Boxes - Rough-In Inspection.
Thank you & have a nice day! Phone #: ###-#### >> Inspection requested via web by JENNY EMEL Inspection cancelled from web by: JENNY EMEL
|
ELE13-02178
| Final | 6/28/2019 | 7/1/2019 | 6/28/2019 2:08:12 PM | A | PASS |
|
|
Tom Phone #: ###-####... service inspected at time of inspection on a solar project 6/28/19...grounding updated and fully labelled...ok to final
|