PLM18-02472
| PLM-Aging Inspection | 7/1/2019 | 7/1/2019 | 7/2/2019 6:20:04 AM | | PART |
|
|
No calls
|
PLM19-02308
| Plumbing Rough-in | 7/1/2019 | 7/1/2019 | 7/1/2019 3:19:12 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jason Adams-Need to fix flat & reverse backgrade. Need to use approved glue. Santees are only approved for drainage in the vertical. Missing nailplates. DWV test fail. Need to finish rough-in. Need to wrap piping in ground work.
|
PLM19-02437
| Plumbing Rough-in | 7/1/2019 | 7/1/2019 | 7/1/2019 2:56:44 PM | P | FAIL |
|
|
Anthony Phone #: ###-####-Need to fix backgrade and plumb per plans or resubmit plans.-Need to install a dbca on water supply with a thermal expantion tank.
|
PLM19-02725
| Plumbing Rough-in | 7/1/2019 | 7/1/2019 | 7/1/2019 2:46:23 PM | P | PASS |
|
|
Vents were not piped through the roof as they were still sheeting the roof and they still have to finish interior framing before we tied vents together Phone #: ###-#### Inspection requested via web by Bill Harmon
|
PLM19-02623
| Sprinkler (Final) | 7/1/2019 | 7/1/2019 | 7/1/2019 2:27:19 PM | P | PASS |
|
|
Justin Phone #: ###-####
|
PLM19-01506
| Final | 7/1/2019 | 7/1/2019 | 7/1/2019 2:14:22 PM | P | PASS |
|
|
Garage code 0820 Phone #: ###-#### Inspection requested via web by Cory Ogden
|
MEC19-02813
| Rough-in | 6/28/2019 | 7/1/2019 | 7/1/2019 2:01:48 PM | P | CANC |
|
|
KELSEY ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|
PLM19-02678
| Final | 6/26/2019 | 7/1/2019 | 7/1/2019 1:46:38 PM | P | PASS |
|
|
Please call John to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
|
PLM19-01499
| Plumbing Rough-in | 7/1/2019 | 7/1/2019 | 7/1/2019 1:27:52 PM | P | PART |
|
|
Good Morning Eric, This is to look at a small section of Potable Water to a Safety Shower at the new Gas Plant. Our office is still next to the Tall White Tower out back. Thank you. Phone #: ###-#### Inspection requested via web by RM Mechanical-Ok to cover waterline.
|
MIS19-00187
| PLM-Final | 7/1/2019 | 7/1/2019 | 7/1/2019 12:49:48 PM | P | PART |
|
|
Jerad Phone #: ###-####-Need to install a DBCA for premis protection with a thermal expantion tank.
|
PLM19-01129
| Final | 7/1/2019 | 7/1/2019 | 7/1/2019 12:26:05 PM | P | PASS |
|
|
|
PLM19-02727
| Sprinkler (Final) | 7/1/2019 | 7/1/2019 | 7/1/2019 12:25:52 PM | P | PASS |
|
|
Tom Phone #: ###-####
|
PLM19-01127
| Final | 7/1/2019 | 7/1/2019 | 7/1/2019 12:25:39 PM | P | PASS |
|
|
|
PLM19-02726
| Sprinkler (Final) | 7/1/2019 | 7/1/2019 | 7/1/2019 12:25:20 PM | P | PASS |
|
|
Tom Phone #: ###-####
|
PLM19-02687
| Sprinkler (Final) | 6/27/2019 | 7/1/2019 | 7/1/2019 11:13:19 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Greg Day
|
PLM19-02688
| Sprinkler (Final) | 6/27/2019 | 7/1/2019 | 7/1/2019 11:13:05 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Greg Day
|
PLM19-01127
| Plumbing Rough-in | 7/1/2019 | 7/1/2019 | 7/1/2019 10:59:24 AM | P | CANC |
|
|
|
PLM19-02547
| Sprinkler (Final) | 6/28/2019 | 7/1/2019 | 7/1/2019 10:47:33 AM | A | PASS |
|
|
Nate Phone #: ###-####
|
PLM19-02546
| Sprinkler (Final) | 6/28/2019 | 7/1/2019 | 7/1/2019 10:43:04 AM | A | PASS |
|
|
Nate Phone #: ###-####
|
MEC19-00786
| Final | 6/28/2019 | 7/1/2019 | 7/1/2019 10:15:26 AM | A | PASS |
|
|
Garage code: 4224 Phone #: ###-#### Inspection requested via web by Dan Otero
|
PLM19-01047
| Final | 7/1/2019 | 7/1/2019 | 7/1/2019 9:51:58 AM | A | PART |
|
|
Project is trimmed out with exception of Freestanding Tub in master, missing part for drain. Please partial for occupancy, may be 3 weeks for part. Phone #: ###-#### Inspection requested via web by Scott Sparrell-Need to caulk all fixtures and finish trim.
|
PLM19-02437
| Plumbing Rough-in | 6/25/2019 | 7/1/2019 | 7/1/2019 9:06:38 AM | A | NH |
|
|
Anthony Phone #: ###-####-No access, left notice.
|
PLM19-02308
| Plumbing Rough-in | 6/28/2019 | 7/1/2019 | 7/1/2019 8:44:32 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Jason Adams
|
PLM19-00756
| Plumbing Rough-in | 7/1/2019 | 7/1/2019 | 7/1/2019 8:28:56 AM | A | PART |
|
|
I will need to be done by 10:15 am. Phone #: ###-#### Inspection requested via web by Martin Bilbao-Went over corrections need to be made.
|
PLM19-00756
| Water and/or Sewer | 6/28/2019 | 7/1/2019 | 7/1/2019 7:39:24 AM | A | CANC |
|
|
I will need to be done by 10:15 am. Phone #: ###-#### Inspection requested via web by Martin Bilbao
|
PLM18-02475
| PLM-Aging Inspection | 7/1/2019 | 7/1/2019 | 7/1/2019 6:17:07 AM | | PART |
|
|
No calls
|
PLM18-04260
| PLM-Aging Inspection | 7/1/2019 | 7/1/2019 | 7/1/2019 6:16:06 AM | | PASS |
|
|
|
PLM18-04260
| DOC - Permit Expired | 7/1/2019 | 7/1/2019 | 7/1/2019 6:15:58 AM | A | PASS |
|
|
|