Inspections for the day of: Monday, July 10, 2006.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD06-00337 BLD-Energy code compliance7/10/20067/10/20067/10/2006 4:20:21 PMPPASS
chris ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
BLD06-00337 BLD-Framing/Rough-in7/10/20067/10/20067/10/2006 4:20:09 PMPPASS
chris ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
BLD06-00794 BLD-Foundation7/10/20067/10/20067/10/2006 4:01:18 PMPPASS
doug - conctrete around 1pm; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
BLD06-00795 BLD-Foundation7/10/20067/10/20067/10/2006 4:01:03 PMPPASS
doug - conctrete around 1pm; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
BLD06-00811 BLD-Foundation7/10/20067/10/20067/10/2006 4:00:47 PMPPASS
doug - conctrete around 1pm; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
BLD06-00810 BLD-Foundation7/10/20067/10/20067/10/2006 4:00:31 PMPPASS
doug - conctrete around 1pm; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
BLD06-00876 BLD-Energy code compliance7/6/20067/10/20067/10/2006 3:42:14 PMPPASS
dennis; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD04-03025 BLD-Framing/Rough-in7/10/20067/10/20067/10/2006 3:32:53 PMPFAIL
Scheduled by a contractor via Hello! on 7/10/2006 at 7:10:24 AM. Contact: ###-####. straps for dragtrusses not installed, roof framing for poolroom.
BLD06-01558 BLD-Conference7/10/20067/10/20067/10/2006 2:22:12 PMPDONE
don - call prior for directions; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley. verified wall to door distance 18" as per approved plan for ADA
BLD05-03035 BLD-Final7/7/20067/10/20067/10/2006 2:04:47 PMPFAIL
REED - nOTE; PLEASE CALL FOR CODE; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Needs to add smoke detectors in bedrooms and step out backdoors. was going to part, due to pool is not complete.
BLD05-02394 BLD-Framing/Rough-in7/10/20067/10/20067/10/2006 1:45:58 PMPPASS
charlie; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley. mezz. framing in existing bldg.
BLD05-03330 BLD-Framing/Rough-in7/9/20067/10/20067/10/2006 11:26:38 AMACANC
Internet Inspection Request from: Carey Allen. contractor called and cancelled.
BLD06-01291 BLD-Final7/7/20067/10/20067/10/2006 11:06:37 AMAPASS
kurt; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
BLD06-01291 DOC - Permit Finaled7/10/20067/10/20067/10/2006 11:06:28 AMPPASS
Recieved and reviewed letter from engineer for structural attachment to existing bldg. ok.
BLD06-00970 BLD-Framing/Rough-in7/7/20067/10/20067/10/2006 10:53:58 AMAFAIL
JOE; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Complete all lateral bracing. Provide approved fixes ffor broken trussses. Provide engineered fix for inadequate bearing on T04 truss. Complete nailing on all hangars on jack trusses and floor trusses. Justify headers over garage doors, not per plan. All ML beams redlined on approved plans were not installed, provide engineering for floor joist used. c/n posted. not ok to insul
BLD06-01265 BLD-Framing/Rough-in7/7/20067/10/20067/10/2006 9:37:36 AMANR
DEWAYNE; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. no truss engineering.
BLD06-00223 BLD-Footing7/7/20067/10/20067/10/2006 9:15:31 AMAPART
pat; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley. Needs to add additional rebar at interior column pad footing. contractor was notified.
BLD05-00274 BLD-Framing/Rough-in7/7/20067/10/20067/10/2006 8:57:21 AMAFAIL
darby; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley. Repairs not yet completed.
MIS05-00045 MIS-Aging Inspection7/10/20067/10/20067/10/2006 8:20:32 AM CANC
MIS05-00026 MIS-Aging Inspection7/10/20067/10/20067/10/2006 8:19:09 AM CANC
BLD04-02319 BLD-Aging Inspection7/10/20067/10/20067/10/2006 8:05:50 AM DONE
BLD04-02319 DOC - Permit Finaled7/10/20067/10/20067/10/2006 8:05:41 AMPPASS
BLD04-02560 BLD-Aging Inspection7/10/20067/10/20067/10/2006 8:04:16 AM DONE
BLD04-02560 DOC - Permit Finaled7/10/20067/10/20067/10/2006 8:04:07 AMPPASS