ELE08-01066
| ELE-Aging Inspection | 7/10/2008 | 7/10/2008 | 7/10/2008 3:38:50 PM | | PART |
|
|
waiting for contr to request final
|
ELE08-01660
| Permanent Service | 7/9/2008 | 7/10/2008 | 7/10/2008 3:38:15 PM | P | NR |
|
|
We have scheduled with IPCO to open the transformer in the morning so we can push in the service wire. We should be ready for inspection by 11 am so if we can get the inspection early in the afternoon it would be greatly appreciated. The pump which is running on the temp service is needed for water pressure to the nearby users so minimizing down time is our goal. We appreciate all your help. Brett will be on site and his cell # is ###-####. Thanks Internet Inspection Request from: Jamie Winters could not locate suzi rating for p/s gear
|
ELE08-01900
| Electrical Rough-In | 7/10/2008 | 7/10/2008 | 7/10/2008 3:37:08 PM | P | FAIL |
|
|
Dan Phone #: ###-#### corr called needs switch and outside light, needs concrete encased electrode, needs panel at out building
|
ELE08-01903
| Permanent Service | 7/10/2008 | 7/10/2008 | 7/10/2008 1:30:10 PM | P | PASS |
|
|
Paula Phone #: ###-#### p/s u/g for meter ok
|
ELE08-01904
| Permanent Service | 7/10/2008 | 7/10/2008 | 7/10/2008 1:29:48 PM | P | PASS |
|
|
Paula Phone #: ###-#### p/s u/g for meter ok
|
ELE08-01419
| Electrical Rough-In | 7/10/2008 | 7/10/2008 | 7/10/2008 12:50:53 PM | P | PART |
|
|
Jack, I need the first floor walls inspected in the office area''s, Mucho will be on site until 3:00PM to walk you through the area''s. Thx. Wayne Phone #: ###-#### Internet Inspection Request from: Wayne Craig ok
|
ELE08-01419
| Conference | 7/10/2008 | 7/10/2008 | 7/10/2008 12:50:37 PM | P | DONE |
|
|
Jack, I need the first floor walls inspected in the office area''s, Mucho will be on site until 3:00PM to walk you through the area''s. Thx. Wayne Phone #: ###-#### Internet Inspection Request from: Wayne Craig correction posted for equipment (printing presses) not listed or labeled, BCC 4.5.60. NEC 110.2
|
ELE08-01650
| Electrical Rough-In | 7/10/2008 | 7/10/2008 | 7/10/2008 11:42:55 AM | A | PART |
|
|
u/g ok
|
ELE08-00554
| Electrical Rough-In | 7/9/2008 | 7/10/2008 | 7/10/2008 10:04:46 AM | A | PART |
|
|
Soffit inspection Phone #: ###-#### Internet Inspection Request from: Brandon Blackham ok
|
ELE08-01893
| Electrical Rough-In | 7/9/2008 | 7/10/2008 | 7/10/2008 9:30:23 AM | A | PASS |
|
|
Potting, Bonding Underground Phone #: ###-#### Internet Inspection Request from: Jenni Keller ok
|
ESC08-00570
| Random Inspection | 7/10/2008 | 7/10/2008 | 7/10/2008 9:30:04 AM | A | PART |
|
|
ok
|
ELE08-00878
| ELE-Aging Inspection | 7/10/2008 | 7/10/2008 | 7/10/2008 8:44:11 AM | | DONE |
|
|
|
ELE08-00878
| Final | 7/10/2008 | 7/10/2008 | 7/10/2008 8:44:01 AM | A | PASS |
|
|
ok
|
ELE08-01895
| Electrical Rough-In | 7/9/2008 | 7/10/2008 | 7/10/2008 8:12:50 AM | A | PASS |
|
|
Ryan-note: the outside plus came off of nonground gfi Phone #: ###-#### ok
|
ELE08-01895
| Final | 7/10/2008 | 7/10/2008 | 7/10/2008 8:12:37 AM | A | PASS |
|
|
Ryan-note: the outside plus came off of nonground gfi Phone #: ###-#### ok
|