Inspections for the day of: Wednesday, July 10, 2013.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-00276 ELE-Aging Inspection7/10/20137/10/20137/10/2013 3:45:35 PM DONE
Waiting on owner
ELE13-01193 Final7/10/20137/10/20137/10/2013 3:22:53 PMPPASS
Jason-please call for access Phone #: ###-####
Final ok
GCE13-00111 GCE-Temporary Service7/10/20137/10/20137/10/2013 2:41:50 PMPFAIL
Jim ###-####
250.24(A)- Grounding electode conductor shall terminate at same bus bar as grounded electode.
590.6(B)(1)- 240 volt receptical shall be GFCI protected
ELE13-01487 Final7/10/20137/10/20137/10/2013 1:54:45 PMPPASS
Please call Asher Sears if any questions Phone #: ###-#### >> Inspection requested via web by brad williams Final ok
ELE13-01227 Final7/9/20137/10/20137/10/2013 1:50:59 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Patrick Paz Owner moved in, not able to test all recepticals.
Final ok
ELE13-00153 Final7/10/20137/10/20137/10/2013 1:42:27 PMPFAIL
Gregory Phone #: ###-####
210.8 Wet bar recepticals located with in 6' of sink shall be GFCI protected
ELE12-00665 Final7/9/20137/10/20137/10/2013 1:25:58 PMAPASS
Corey Phone #: ###-#### UL listing confirmed.
Final ok
ELE12-01710 Electrical Rough-In7/10/20137/10/20137/10/2013 10:22:34 AMAPASS
Contact: Wes Powell Phone #: ###-#### >> Inspection requested via web by Deb Gooden Wall rough in 18th floor as noted on contractors print rough in ok cover
ELE13-01769 Final7/9/20137/10/20137/10/2013 9:23:42 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Clay Morgan
Final ok
ELE13-00390 Electrical Rough-In7/9/20137/10/20137/10/2013 8:59:59 AMAPASS
keith Phone #: ###-#### Rough in ok cover
ELE13-01702 Electrical Rough-In7/9/20137/10/20137/10/2013 8:48:40 AMAPASS
Before 10:30 please - Tyler Phone #: ###-####
Basement rough in ok cover
ELE13-00324 Final7/9/20137/10/20137/10/2013 8:16:11 AMAPASS
Brandon Please call 30 min before going out Phone #: ###-#### Final ok
ESC12-01162 General Inspection7/8/20137/10/20137/9/2013 4:11:10 PMAFAIL
hill right of drive Correction not complete. Granted extra time do to RP leaving state. Will reinspect 7/11/13
ELE13-01502 Final7/9/20137/10/20137/9/2013 3:52:26 PMAFAIL
Truck is on site for final Phone #: ###-#### >> Inspection requested via web by Randy Fletcher
400.5(A)- Type SEOOW #10 GA. cord 25 amp max overcurrent device.
406.6- Overcurrent device exccedes rating of recepticals.
110.3- Installation of attachment cord, cord jacket does not reach clamp of plug.