ELE10-00276
| ELE-Aging Inspection | 7/10/2013 | 7/10/2013 | 7/10/2013 3:45:35 PM | | DONE |
|
|
Waiting on owner
|
ELE13-01193
| Final | 7/10/2013 | 7/10/2013 | 7/10/2013 3:22:53 PM | P | PASS |
|
|
Jason-please call for access Phone #: ###-#### Final ok
|
GCE13-00111
| GCE-Temporary Service | 7/10/2013 | 7/10/2013 | 7/10/2013 2:41:50 PM | P | FAIL |
|
|
Jim ###-#### 250.24(A)- Grounding electode conductor shall terminate at same bus bar as grounded electode. 590.6(B)(1)- 240 volt receptical shall be GFCI protected
|
ELE13-01487
| Final | 7/10/2013 | 7/10/2013 | 7/10/2013 1:54:45 PM | P | PASS |
|
|
Please call Asher Sears if any questions Phone #: ###-#### >> Inspection requested via web by brad williams Final ok
|
ELE13-01227
| Final | 7/9/2013 | 7/10/2013 | 7/10/2013 1:50:59 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Patrick Paz Owner moved in, not able to test all recepticals. Final ok
|
ELE13-00153
| Final | 7/10/2013 | 7/10/2013 | 7/10/2013 1:42:27 PM | P | FAIL |
|
|
Gregory Phone #: ###-#### 210.8 Wet bar recepticals located with in 6' of sink shall be GFCI protected
|
ELE12-00665
| Final | 7/9/2013 | 7/10/2013 | 7/10/2013 1:25:58 PM | A | PASS |
|
|
Corey Phone #: ###-#### UL listing confirmed. Final ok
|
ELE12-01710
| Electrical Rough-In | 7/10/2013 | 7/10/2013 | 7/10/2013 10:22:34 AM | A | PASS |
|
|
Contact: Wes Powell Phone #: ###-#### >> Inspection requested via web by Deb Gooden Wall rough in 18th floor as noted on contractors print rough in ok cover
|
ELE13-01769
| Final | 7/9/2013 | 7/10/2013 | 7/10/2013 9:23:42 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Clay Morgan Final ok
|
ELE13-00390
| Electrical Rough-In | 7/9/2013 | 7/10/2013 | 7/10/2013 8:59:59 AM | A | PASS |
|
|
keith Phone #: ###-#### Rough in ok cover
|
ELE13-01702
| Electrical Rough-In | 7/9/2013 | 7/10/2013 | 7/10/2013 8:48:40 AM | A | PASS |
|
|
Before 10:30 please - Tyler Phone #: ###-#### Basement rough in ok cover
|
ELE13-00324
| Final | 7/9/2013 | 7/10/2013 | 7/10/2013 8:16:11 AM | A | PASS |
|
|
Brandon Please call 30 min before going out Phone #: ###-#### Final ok
|
ESC12-01162
| General Inspection | 7/8/2013 | 7/10/2013 | 7/9/2013 4:11:10 PM | A | FAIL |
|
|
hill right of drive Correction not complete. Granted extra time do to RP leaving state. Will reinspect 7/11/13
|
ELE13-01502
| Final | 7/9/2013 | 7/10/2013 | 7/9/2013 3:52:26 PM | A | FAIL |
|
|
Truck is on site for final Phone #: ###-#### >> Inspection requested via web by Randy Fletcher 400.5(A)- Type SEOOW #10 GA. cord 25 amp max overcurrent device. 406.6- Overcurrent device exccedes rating of recepticals. 110.3- Installation of attachment cord, cord jacket does not reach clamp of plug.
|