PLM17-01656
| Plumbing Rough-in | 7/7/2017 | 7/10/2017 | 7/10/2017 4:37:09 PM | P | PASS |
|
|
JOB # 50716 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM17-01872
| Final | 7/10/2017 | 7/10/2017 | 7/10/2017 4:19:47 PM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Branden Steers
|
PLM16-04508
| PLM-Aging Inspection | 7/10/2017 | 7/10/2017 | 7/10/2017 3:58:25 PM | | PEND |
|
|
Office checking on status
|
PLM17-02525
| Groundwork | 7/10/2017 | 7/10/2017 | 7/10/2017 3:57:54 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Nels Moore
|
PLM17-01210
| Water Heater Final | 7/10/2017 | 7/10/2017 | 7/10/2017 3:46:14 PM | P | FAIL |
|
|
1. Install a listed gasketed door with threshold and install the combustion air from the outside per ISPC 504.1/506.4. 2. Pipe the t&p and pan drain to the outside of the house and hang every 4ft. 3. Remove the flex connector from the t&p and hardpipe.
|
PLM17-02526
| Final | 7/10/2017 | 7/10/2017 | 7/10/2017 3:42:19 PM | P | FAIL |
|
|
Would like early PM and call on way. Phone #: ###-#### Inspection requested via web by Xanti Berria. 1. Install a listed, self-closing door with a threshold and provide combustion air from the exterior. ISPC 504.1 and 506.4. 2. Pipe the drain pan and t&p to the exterior and strap every 4ft.
|
PLM17-02521
| Water and/or Sewer | 7/10/2017 | 7/10/2017 | 7/10/2017 2:09:48 PM | P | PASS |
|
|
|
PLM17-02521
| Final | 7/10/2017 | 7/10/2017 | 7/10/2017 2:09:32 PM | P | PASS |
|
|
|
PLM17-02515
| Groundwork | 7/7/2017 | 7/10/2017 | 7/10/2017 11:22:13 AM | A | PASS |
|
|
Please call Kinley 30 min before inspection Phone #: ###-#### Inspection requested via web by Brian Johansen. Contractor to remove the secition of 4" abs that was not tied back into the system.
|
PLM17-02350
| Sprinkler (Final) | 7/7/2017 | 7/10/2017 | 7/10/2017 10:46:54 AM | A | CANC |
|
|
Todd Phone #: ###-####. Contractror to add 2" foam block insulation to shut-off riser sleeve due to shallow water service riser.
|
PLM17-02521
| Water and/or Sewer | 7/9/2017 | 7/10/2017 | 7/10/2017 10:19:55 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Darren Wood
|
PLM17-01872
| Final | 7/10/2017 | 7/10/2017 | 7/10/2017 9:55:58 AM | A | FAIL |
|
|
Increase the water heater drain pan 2" min. per manufacturers instructions. Strap the t&p
|
PLM17-02517
| Plumbing Rough-in | 7/8/2017 | 7/10/2017 | 7/10/2017 9:28:30 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Branden Steers
|
PLM16-02272
| PLM-Aging Inspection | 7/10/2017 | 7/10/2017 | 7/10/2017 8:29:51 AM | | PASS |
|
|
|
PLM16-02272
| DOC - Permit Expired | 7/10/2017 | 7/10/2017 | 7/10/2017 8:29:38 AM | A | PASS |
|
|
No response
|