Inspections for the day of: Tuesday, July 10, 2018.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-03002 PLM-Aging Inspection7/10/20187/10/20187/12/2018 3:57:41 PM PASS
PLM18-02880 Other7/9/20187/10/20187/10/2018 5:02:44 PMPPASS
late as possible (closest to 4 would be best)// conference // Charles Phone #: ###-####
PLM18-02878 Plumbing Rough-in7/9/20187/10/20187/10/2018 4:20:36 PMPPART
Phone #: ###-#### Inspection requested via web by Nicholas Paige.
The plumbing is not per plans. I left a message for Cody, the site plumber to call for information.
PLM17-03935 PLM-Aging Inspection7/10/20187/10/20187/10/2018 3:39:07 PM PASS
PLM17-03935 DOC - Permit Expired7/10/20187/10/20187/10/2018 3:38:58 PMPPASS
Contractor failed to respond.
PLM18-02885 Final7/10/20187/10/20187/10/2018 3:37:49 PMPPASS
Phone #: ###-#### Inspection requested via web by DANIELLE BROOKSHIRE
PLM18-02885 DOC - Permit Finaled7/10/20187/10/20187/10/2018 3:37:34 PMPPASS
PLM18-02789 Water Heater Final7/5/20187/10/20187/10/2018 3:36:41 PMPNH
Please call owner Chris or Kathleen when on the way ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Jennifer Alcala.
Not home. Left a tag on the door to call
PLM18-02859 Water Heater Final7/6/20187/10/20187/10/2018 12:47:49 PMPPASS
PLEASE CALL AHEAD ###-#### Phone #: ###-#### Inspection requested via web by Chris Field
PLM18-02860 Plumbing Rough-in7/9/20187/10/20187/10/2018 12:31:19 PMAPASS
please call Thomas when en route ###-####- thank you Phone #: ###-#### Inspection requested via web by Nick Drake
PLM18-00557 Final7/9/20187/10/20187/10/2018 12:06:56 PMANH
Call Dan Beck to get in 2086002515 Phone #: ###-#### Inspection requested via web by sandy moncarr reschduled
PLM18-01145 Final7/9/20187/10/20187/10/2018 11:49:45 AMAPASS
#51230 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM18-02889 Sprinkler (Final)7/10/20187/10/20187/10/2018 11:28:09 AMPPART
Please contact Luis @ ###-#### for any questions. Phone #: ###-#### Inspection requested via web by Marisela Huitron.
This permit was pulled for an address that is no longer valid. Pull new permits for all four address under the new addresses.
OK to cover
PLM18-01162 Final7/9/20187/10/20187/10/2018 11:10:27 AMAPASS
Phone #: ###-#### Inspection requested via web by Ryan Baker
PLM18-02294 Plumbing Rough-in7/9/20187/10/20187/10/2018 10:57:26 AMAFAIL
Key is on the ledge above the door. Nobody lives there currently. Phone #: ###-#### Inspection requested via web by TOBI WLSON
1. The water heater flue requires a 1" clearance from all combustable material.
2. The T&P drain must be ran to the exterior or an approved location. If trapped drill an 1/8" hole in the low point.
3. Provide and air gap at the water softener drain termination.
PLM18-01943 Water and/or Sewer7/9/20187/10/20187/10/2018 10:28:54 AMAPASS
Eric came out and looked to approve bury except connections. Meters are live Phone #: ###-#### Inspection requested via web by Mark Kelso
PLM18-02817 Water Heater Final7/5/20187/10/20187/6/2018 8:50:29 AMPCANC
OWNER: DONNELLA IANZITI, ###-####. PLEASE CALL AHEAD. THANKS! Phone #: ###-#### >> Inspection requested via web by Chris Field Inspection cancelled from web by: Chris Field