Inspections for the day of: Wednesday, July 10, 2019.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-02192 Electrical Rough-In7/10/20197/10/20197/10/2019 2:23:30 PMPPASS
Call tony with any questions ###-#### Phone #: ###-#### Inspection requested via web by Clayton Morgan Ok cover
ELE19-02549 Electrical Rough-In7/10/20197/10/20197/10/2019 2:23:08 PMPNH
Home owner will be there. Any questions please let me know. Thank you Phone #: ###-#### Inspection requested via web by David Kubik
ELE19-02518 Electrical Rough-In7/10/20197/10/20197/10/2019 1:34:33 PMPPASS
Please call Rick @2088807791 for access , he will be there! Thx Steve Phone #: ###-#### Inspection requested via web by Steven Meredith Ok cover upstairs
ELE19-02475 Rough-In Permanent Service7/9/20197/10/20197/10/2019 1:14:51 PMPPASS
Phone #: ###-#### Inspection requested via web by Zane Robertson p/s u/g n ok
ELE19-02548 Permanent Service7/10/20197/10/20197/10/2019 12:44:13 PMPPASS
Need perm service inspection for IDPCO re-connection.
need inspection around 2pm if possible so we can call IDPCO for re-connect.
this is a single fam residential service Phone #: ###-#### Inspection requested via web by Todd Hall p/s o/h n ok
ELE19-01698 Permanent Service7/10/20197/10/20197/10/2019 12:34:29 PMPPASS
Phone #: ###-#### Inspection requested via web by Emmet Bushman p/s o/h n ok
ELE19-02546 Permanent Service7/10/20197/10/20197/10/2019 12:10:35 PMPCANC
Phone #: ###-#### Inspection requested via web by Jim Williams
ELE18-03478 Final7/10/20197/10/20197/10/2019 11:42:46 AMPPASS
Phone #: ###-#### Inspection requested via web by William Andrews Ok final. Unit was a B&B, could not access all recepts. 2 blanks were needed on furnace front downstairs, and brkr changed for mini split. Both were done, contractor was there.
ELE18-04293 Final7/9/20197/10/20197/10/2019 11:41:19 AMAFAIL
Should be open all day if not call me thanks Phone #: ###-#### Inspection requested via web by Kevin Oderkirk
1. Grocery counter recept needs to be removed and blanked. You cannot extend of bath GFI.
2. GFI needed in washer outlet.
3. Recept needed below 3 gang in mstr bed just before entry to bath. 2 ft wall space.
4. 2 recepts needed in dining above cabinet. 210.52.
ELE19-02415 Final7/8/20197/10/20197/10/2019 11:35:33 AMAFAIL
Inspection requested via web by BRS Permitting No access. Knocked on door this morning, no answer. No contact info for homeowner or contractor. Re-inspect fee applies.
ELE19-01974 Final7/10/20197/10/20197/10/2019 11:02:54 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M Ok final.
ELE19-02166 Final7/9/20197/10/20197/10/2019 10:17:03 AMAPASS
please call prior to arrival for access. Phone #: ###-#### Inspection requested via web by Patrick Paz Ok final up bath.
ELE19-02546 Final7/10/20197/10/20197/10/2019 9:54:40 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Jim Williams Inspection cancelled from web by: Jim Williams
ELE19-02496 Final7/9/20197/10/20197/10/2019 9:38:11 AMPCANC
Same job as rough-in. I have numerous pictures I can also send. Everything weatherproof, GFCI protected, WR TR Outlets. Some junction boxes for future sealed off and safe. Homeowner is Lynn Williams. If she isn''t home just go through the side gate. All work is back patio Phone #: ###-#### >> Inspection requested via web by David McClellan Inspection cancelled from web by: David McClellan
ELE19-02496 Electrical Rough-In7/8/20197/10/20197/10/2019 9:15:57 AMAPASS
Phone #: ###-#### Inspection requested via web by David McClellan Ok cover patio. Waiting on sconce lights and ceiling fan
ELE19-02538 Electrical Rough-In7/9/20197/10/20197/10/2019 9:15:10 AMAPASS
pool bonding Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Ok cover 4 corners bonding. 3 LV lights on E side.
ELE17-00191 ELE-Aging Inspection7/10/20197/10/20197/10/2019 6:00:34 AM DONE
Again, please schedule a final inspection. Need to coordinate with a contact onsite. Fees may apply if not completed.