Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-02036 Electrical Rough-In7/10/20027/11/20027/11/2002 12:00:00 AMAPASS
TODD ###-#### PLEASE CALL SO TODD CAN MEET YOU THERE r/i ok

p/s u/g new ok 7/11/2002 12:18:23 PM
ELE02-01774 Final7/10/20027/11/20027/11/2002 12:00:00 AMAPART
Scheduled by a contractor via Hello! on 07/10/2002 at 16:51:52. Contact: ###-####. temp for 2 spaces only 7/11/2002 10:50:36 AM
ELE02-01832 Electrical Rough-In7/10/20027/11/20027/11/2002 12:00:00 AMAPASS
bill- ###-####-ok to cover ok 7/11/2002 11:43:36 AM
ELE02-02052 Electrical Rough-In7/10/20027/11/20027/11/2002 12:00:00 AMAPASS
###-#### CONFERENCE CALL FIRST r/i ok 7/11/2002 1:54:26 PM
ELE02-01999 Final7/10/20027/11/20027/11/2002 12:00:00 AMAPASS
###-#### richard call 1st please ok 7/11/2002 11:18:17 AM
ELE02-02084 Temporary Service7/10/20027/11/20027/11/2002 12:00:00 AMAFAIL
kevin ###-#### cor. posted $45.00 reinspection fee due short grd rod needs to drive 2 grd rods now 7/11/2002 12:19:33 PM
ELE02-01681 Final7/10/20027/11/20027/11/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 07/10/2002 at 13:36:20. Contact: ###-####.ok card signed 7/11/2002 5:14:45 PM
ELE02-01950 Electrical Rough-In7/10/20027/11/20027/11/2002 12:00:00 AMPCANC
Scheduled by a contractor via Hello! on 07/10/2002 at 15:59:44. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on 07/11/2002 at 07:33:14.
ELE02-01890 Final7/11/20027/11/20027/11/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 07/11/2002 at 07:54:58. Contact: ###-####. ok 7/11/2002 6:18:18 PM
ELE02-02109 Rough-In Permanent Service7/11/20027/11/20027/11/2002 12:00:00 AMPFAIL
###-#### roger cor. posted called 300.(A)(1)&(D) 210.52(A) outlet required for wall space in kit. right of pantry, 314.20 boxes not flush with finish surface 7/11/2002 3:51:00 PM
ELE02-02110 Rough-In Permanent Service7/11/20027/11/20027/11/2002 12:00:00 AMPFAIL
BOB ###-#### CELL ###-#### cor. posted called 300.4(A)(1)and(D) 314.20 inside and outside not flush with finish surface, 210.52 (A&B) outlet in nook on kit. circuit shall not serve as outlet for wall spacing in family rm 7/11/2002 3:04:25 PM
ELE02-02120 Final7/11/20027/11/20027/11/2002 12:00:00 AMPPASS
pat ###-#### a/c ok 7/11/2002 5:40:17 PM
ELE02-01786 Final7/11/20027/11/20027/11/2002 12:00:00 AMPPASS
allison -###-#### fn -gar door is open ok see added p/s inspection 7/11/2002 6:02:20 PM
ELE02-02052 Permanent Service7/11/20027/11/20027/11/2002 12:00:00 AMPPASS
p/s u/g new ok
ELE02-01786 Permanent Service7/11/20027/11/20027/11/2002 12:00:00 AMPPASS
p/s o/h rec. ok