ELE12-01968
| ELE-Aging Inspection | 7/11/2014 | 7/11/2014 | 7/17/2014 2:37:35 PM | | DONE |
|
|
Spoke to contractor he will check and call in
|
ELE12-02026
| ELE-Aging Inspection | 7/11/2014 | 7/11/2014 | 7/14/2014 3:09:14 PM | | DONE |
|
|
Called and left message
|
ELE12-02027
| ELE-Aging Inspection | 7/11/2014 | 7/11/2014 | 7/14/2014 3:02:14 PM | | DONE |
|
|
Called left message
|
ELE14-01411
| Final | 7/11/2014 | 7/11/2014 | 7/11/2014 2:46:38 PM | P | PASS |
|
|
Please call half an hour before thank Shaun. 2089416264 Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Final ok
|
ELE14-01893
| Final | 7/11/2014 | 7/11/2014 | 7/11/2014 2:36:46 PM | P | PASS |
|
|
All rough in inspection performed by state inspectors by mistake. Unsupported box and conduit removed. Final ok
|
ELE14-01584
| Final | 7/11/2014 | 7/11/2014 | 7/11/2014 1:54:30 PM | P | PASS |
|
|
John-please call 1/2 hr prior for access Phone #: ###-#### Final ok
|
ELE14-01889
| Final | 7/11/2014 | 7/11/2014 | 7/11/2014 1:33:09 PM | P | FAIL |
|
|
We Wired A New A/C And outlet Thanks Phone #: ###-#### >> Inspection requested via web by jason shifflett 400.8- Flexible cable shall not be ran in walls or attic spaces. Exception for split systems, flexible cord shall be allowed if installed in comlete raceway system.
|
ELE14-01893
| Final | 7/11/2014 | 7/11/2014 | 7/11/2014 12:51:13 PM | P | FAIL |
|
|
Electrical rough-in inspection completed by the State Electrical Inspector. Contact Doug Pody Boise City if any questions. Phone #: ###-#### >> Inspection requested via web by Celinda Winters All rough in inspections were performed by state inspectors by mistake. 314.23- Box located on east wall on 1" pvc conduit shall be regedly and securely fastened in place.
|
ELE14-01335
| Final | 7/11/2014 | 7/11/2014 | 7/11/2014 12:18:23 PM | P | FAIL |
|
|
Any questions please let me know, thx, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren 406.8(A)- All 15 and 20 amp receptical outlets installed outdoors shall be weather resistant type. 110.3- Unable to test misc swiching due to lamps missing in beds and hallways.
|
ELE13-03283
| Final | 7/10/2014 | 7/11/2014 | 7/11/2014 11:10:20 AM | A | PASS |
|
|
Cody Phone #: ###-#### Final ok
|
ELE14-01714
| Final | 7/10/2014 | 7/11/2014 | 7/11/2014 10:12:55 AM | A | PASS |
|
|
Troy Phone #: ###-#### Final ok
|
ELE14-01875
| Conference | 7/10/2014 | 7/11/2014 | 7/11/2014 9:56:13 AM | A | DONE |
|
|
Please call Clay to meet you ###-####, Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan Discussed relocating service to new addition wall and the tie into the existing ungrounded circuits of house. Not required to change interior wiring where not accessible. Will ensure two wire receptical outlets are installed or GFCI protect grounding type recepticals as per NEC 406.3(D)
|
ELE14-01883
| Permanent Service | 7/10/2014 | 7/11/2014 | 7/11/2014 9:44:37 AM | A | PASS |
|
|
access to service is thru vacant neighbors yard on the south side. Storm Damage replace mast. Idaho power requested inspection Phone #: ###-#### >> Inspection requested via web by Dan Hobdey p/s o/h rec ok
|
ELE14-01883
| Final | 7/11/2014 | 7/11/2014 | 7/11/2014 9:06:33 AM | P | PASS |
|
|
access to service is thru vacant neighbors yard on the south side. Storm Damage replace mast. Idaho power requested inspection Phone #: ###-#### >> Inspection requested via web by Dan Hobdey Service repair final ok
|
ELE14-01030
| Final | 7/10/2014 | 7/11/2014 | 7/11/2014 8:50:35 AM | A | PASS |
|
|
call for code Phone #: ###-#### >> Inspection requested via web by Neal Rumsey Final ok
|