Inspections for the day of: Friday, July 11, 2014.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01968 ELE-Aging Inspection7/11/20147/11/20147/17/2014 2:37:35 PM DONE
Spoke to contractor he will check and call in
ELE12-02026 ELE-Aging Inspection7/11/20147/11/20147/14/2014 3:09:14 PM DONE
Called and left message
ELE12-02027 ELE-Aging Inspection7/11/20147/11/20147/14/2014 3:02:14 PM DONE
Called left message
ELE14-01411 Final7/11/20147/11/20147/11/2014 2:46:38 PMPPASS
Please call half an hour before thank Shaun. 2089416264 Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Final ok
ELE14-01893 Final7/11/20147/11/20147/11/2014 2:36:46 PMPPASS
All rough in inspection performed by state inspectors by mistake. Unsupported box and conduit removed. Final ok
ELE14-01584 Final7/11/20147/11/20147/11/2014 1:54:30 PMPPASS
John-please call 1/2 hr prior for access Phone #: ###-#### Final ok
ELE14-01889 Final7/11/20147/11/20147/11/2014 1:33:09 PMPFAIL
We Wired A New A/C And outlet Thanks Phone #: ###-#### >> Inspection requested via web by jason shifflett 400.8- Flexible cable shall not be ran in walls or attic spaces. Exception for split systems, flexible cord shall be allowed if installed in comlete raceway system.
ELE14-01893 Final7/11/20147/11/20147/11/2014 12:51:13 PMPFAIL
Electrical rough-in inspection completed by the State Electrical Inspector. Contact Doug Pody Boise City if any questions. Phone #: ###-#### >> Inspection requested via web by Celinda Winters All rough in inspections were performed by state inspectors by mistake. 314.23- Box located on east wall on 1" pvc conduit shall be regedly and securely fastened in place.
ELE14-01335 Final7/11/20147/11/20147/11/2014 12:18:23 PMPFAIL
Any questions please let me know, thx, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren 406.8(A)- All 15 and 20 amp receptical outlets installed outdoors shall be weather resistant type.
110.3- Unable to test misc swiching due to lamps missing in beds and hallways.
ELE13-03283 Final7/10/20147/11/20147/11/2014 11:10:20 AMAPASS
Cody Phone #: ###-#### Final ok
ELE14-01714 Final7/10/20147/11/20147/11/2014 10:12:55 AMAPASS
Troy Phone #: ###-#### Final ok
ELE14-01875 Conference7/10/20147/11/20147/11/2014 9:56:13 AMADONE
Please call Clay to meet you ###-####, Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan Discussed relocating service to new addition wall and the tie into the existing ungrounded circuits of house. Not required to change interior wiring where not accessible. Will ensure two wire receptical outlets are installed or GFCI protect grounding type recepticals as per NEC 406.3(D)
ELE14-01883 Permanent Service7/10/20147/11/20147/11/2014 9:44:37 AMAPASS
access to service is thru vacant neighbors yard on the south side. Storm Damage replace mast. Idaho power requested inspection Phone #: ###-#### >> Inspection requested via web by Dan Hobdey p/s o/h rec ok
ELE14-01883 Final7/11/20147/11/20147/11/2014 9:06:33 AMPPASS
access to service is thru vacant neighbors yard on the south side. Storm Damage replace mast. Idaho power requested inspection Phone #: ###-#### >> Inspection requested via web by Dan Hobdey Service repair final ok
ELE14-01030 Final7/10/20147/11/20147/11/2014 8:50:35 AMAPASS
call for code Phone #: ###-#### >> Inspection requested via web by Neal Rumsey Final ok