Inspections for the day of: Monday, July 11, 2016.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-01274 Final7/8/20167/11/20167/11/2016 4:12:53 PMPFAIL
Final on Building Phone #: ###-#### Inspection requested via web by Bob Stephens440.22(c) Protection device shall not exceed manufacturer value. A/C, Water heater 210.52. Recep shall be located within 24in of sink. 110.25. Lockable disconecting means. Water heater/ Furnace
ELE16-00756 Final7/8/20167/11/20167/11/2016 4:12:13 PMPFAIL
Final on Building M Phone #: ###-#### Inspection requested via web by Bob Stephens 440.22(c) Protection device shall not exceed manufacturer value. A/C, Water heater 210.52. Recep shall be located within 24in of sink. 110.25. Lockable disconecting means. Water heater/ Furnace
ELE16-00602 Final7/11/20167/11/20167/11/2016 2:51:16 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brandon Hillman 440.22 C Protective device shall not exceed manufacturers values. A/C Should be a 20a
ELE16-02194 Conference7/11/20167/11/20167/11/2016 1:23:43 PMPNH
Tyler Phone #: ###-#### Called and left 2 messages. Reschedule
ELE16-02162 Final7/11/20167/11/20167/11/2016 1:22:58 PMPFAIL
Luke Phone #: ###-####406.9 b 1 recepticles in wet locations shall be listed Weather resistant 406.12 A Recepticles in dwelling units shall be tamper resistant 406.5 Recepticles shall be securely mounted. ( All on Shed)
ELE15-03577 Final7/10/20167/11/20167/11/2016 12:47:40 PMPPASS
PLEASE CALL ME WITH APPROX 15 MINUTES NOTICE--THANK YOU. Phone #: ###-#### Inspection requested via web by PAUL PINNEY Final ok
ELE15-03787 Electrical Rough-In7/11/20167/11/20167/11/2016 12:25:08 PMPPASS
Jay Phone #: ###-#### Rough in ok to cover
ELE16-01610 Electrical Rough-In7/8/20167/11/20167/11/2016 10:35:10 AMAPASS
We are requesting a ceiling inspection for monday 7/11/16 in the am. Our contact is Kory @ ###-####. Thank you,
Phone #: ###-#### Inspection requested via web by Clint Tate Ceiling only Ok to cover
ELE16-02186 Electrical Rough-In7/10/20167/11/20167/11/2016 10:14:39 AMAPASS
Phone #: ###-#### Inspection requested via web by Jarod Murray Master Bed, Bath Laundy room Rough in ok to cover
ELE15-03521 Final7/8/20167/11/20167/11/2016 10:14:09 AMAPASS
Phone #: ###-#### Inspection requested via web by Krista Ratterree Final ok
ELE16-01257 Final7/9/20167/11/20167/11/2016 9:24:39 AMAPASS
please call prior to arrival for access and home owner notification Phone #: ###-#### Inspection requested via web by Jarod Murray corrections Made. Final ok
ELE16-00141 Final7/8/20167/11/20167/11/2016 9:14:07 AMAPASS
Tom Phone #: ###-#### Final ojk
ELE16-02174 Rough-In Permanent Service7/8/20167/11/20167/11/2016 9:14:06 AMAPASS
Phone #: ###-#### Inspection requested via web by Zane Robertson Rough in ok. p/s u/g n ok
ELE16-01683 Electrical Rough-In7/10/20167/11/20167/11/2016 9:14:03 AMAPASS
in floor heat inspection. general contractor to be on site. Phone #: ###-#### Inspection requested via web by Garrett Collins Remodel is back side of house. SW Corner Master floor heat. Ok to cover.