Inspections for the day of: Wednesday, July 11, 2018.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-03227 ELE-Aging Inspection7/11/20187/11/20187/13/2018 3:49:44 PM CANC
too busy
ELE13-03214 ELE-Aging Inspection7/11/20187/11/20187/13/2018 10:10:33 AM PASS
permit expired
ELE17-02649 Electrical Rough-In7/10/20187/11/20187/12/2018 7:29:45 AMPPASS
Ceiling inspection - contact is Andy Chambers Phone #: ###-#### Inspection requested via web by Scott Campbell...rms marked on plans
ELE18-01021 Final7/11/20187/11/20187/11/2018 2:29:56 PMPPASS
access 2569 Phone #: ###-#### Inspection requested via web by David Nelson...ok to final
ELE18-02606 Electrical Rough-In7/11/20187/11/20187/11/2018 1:54:10 PMPPASS
wall rough in. Chad VanOrden is contact at ###-####. thank you. Phone #: ###-#### Inspection requested via web by Debby Pierce...1 new wall switch and outlet...ok to cover
ELE18-02445 Electrical Rough-In7/11/20187/11/20187/11/2018 12:37:46 PMPPASS
Tom-underground conduit Phone #: ###-####...ok to cover
ELE18-01167 Final7/11/20187/11/20187/11/2018 12:16:46 PMPFAIL
access 6935 Phone #: ###-#### Inspection requested via web by David Nelson...
unit 1..abrasion protection needs added for romex at bedroom heaters
unit 2..romex protection-heaters
outlets shall not be installed above heater
unit 3..romex protection-heaters
outlets shall not be installed above heater
unit 4 romex protection-heaters
outlets shall not be installed above heater
unit 5..abrasion protection for romex living heater
unit 6..patio light not working
romex protection-heaters
unit 7..living rm heater-junction cover
kitchen outlets need to be completed
panel needs labelled completely
unit 8..panel needs labelled completely
ELE14-00678 ELE-Aging Inspection7/11/20187/11/20187/11/2018 11:17:57 AM PASS
final scheduled and resulted
ELE14-00678 Final7/11/20187/11/20187/11/2018 11:17:35 AMPPASS
UL listing verified and disconnect ok
ELE17-02445 Final7/10/20187/11/20187/11/2018 11:00:18 AMAPART
Please call Mike. Phone #: ###-#### Inspection requested via web by Kevin Perez..marked areas ceiling grids and classrooms...rm 116 1 GFCI needed, exterior outlets WR GFCI, hall 119 GFCI protection for vending machines, HVAC disconnects circuit labelling and service outlet needed
ELE18-02545 Conference7/9/20187/11/20187/11/2018 9:45:48 AMAPASS
If you can give me 30 minutes notice the homeowner will let us in. Thank You. Phone #: ###-#### Inspection requested via web by Craig Korell...discussed service change, existing panel changed to junction box-access oked, service lateral over shed-raise riser to get clearance as much as possible-shed not a permanent structure
ELE18-02048 Electrical Rough-In7/10/20187/11/20187/11/2018 9:22:51 AMAPASS
Austin Jensen, crew lead: ###-####
The install is taking place on 7/11. Phone #: ###-#### Inspection requested via web by BRS Permitting...UL listed equipment verified...30A breaker will be installed in panel
ELE18-02484 Electrical Rough-In7/10/20187/11/20187/11/2018 8:50:50 AMAPASS
rough-in of 2 offices and some wiring on west wall of deck plus north and west wall in warehouse,
Thanks Phone #: ###-#### Inspection requested via web by Rick Beckman...rough ok to cover...verify breaker l/o or disconnect on water heater at final
ELE18-01912 Permanent Service7/10/20187/11/20187/11/2018 8:19:33 AMAPASS
Service inspection pedestal for parking lot lighting. Please contact Cory Sells if needed - ###-#### (I hope I chose the correct insp type) thanks, cyndi Phone #: ###-#### Inspection requested via web by Cyndi Dale...p/s u/g new ok