ELE05-01554
| Final | 7/12/2005 | 7/12/2005 | 7/12/2005 4:15:54 PM | P | PASS |
|
|
darrell; Phone #: ###-#### Internet Inspection Request from: Barbara Moore called contr about a/c, ok to final
|
ELE05-02449
| Permanent Service | 7/11/2005 | 7/12/2005 | 7/12/2005 4:04:13 PM | P | CANC |
|
|
kelly ###-#### talked to contr, address not marked, couldn't find unit contr asked for. owner has to get numbers re-aligned. they will call again once marked.
|
ELE05-01986
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 1:48:53 PM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 1:00:06 PM. told contr, left corr notice,fee due, 408.4 panel schedule shall be complete and detailed,garage gfci mis-wired
|
ELE05-02075
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 1:47:00 PM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 12:54:30 PM. told contr, left corr notice, fee due, 408.4 panel schedule to be specific,352.30 rnc shall be strapped within 3' of box,406.4 recpt shall be tight, west bedroom, laundry, west bed light not working
|
ELE05-01433
| Electrical Rough-In | 7/12/2005 | 7/12/2005 | 7/12/2005 1:23:50 PM | P | PASS |
|
|
please call 10 min prior to inspection to meet///gil; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa met with owner, ric ok
|
ELE05-02451
| Electrical Rough-In | 7/11/2005 | 7/12/2005 | 7/12/2005 12:56:17 PM | P | NR |
|
|
north wall cover inspection, please contact Matt, thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters strapping, ko seals, piping not done, told contr to call again
|
ELE05-01870
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 12:22:47 PM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 12:50:32 PM. Contact: ###-####. told contr, left corr notice, 408.4 circuit directory shall be specific with detail, 352.30 rnc shall be strapped within 3' of box, 210.52 (C)(1) recpt shall be within 24" of sink, fee due
|
ELE05-01985
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 12:16:53 PM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 12:55:40 PM. told contr, left corr notice,408.4 circuit directory shall be specific with detail,352.30 rnc shall be strapped within 3' of panel, recpt east garage, check wiring, 314.15 box shall be listed for wet location, fee due
|
ELE05-02450
| Electrical Rough-In | 7/12/2005 | 7/12/2005 | 7/12/2005 10:37:31 AM | P | CANC |
|
|
Scheduled by a contractor via Hello! on 7/12/2005 at 9:36:16 AM. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on Jul 12 2005 10:37AM.
|
ELE05-01988
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 10:33:44 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 12:59:04 PM. told contr, left corr notice,408.4 panel schedule shall be explicit, 352.30 strap shall be within 3' of box (service riser), kitchen gfci loose,fee due
|
ELE05-02063
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 10:03:29 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 12:57:59 PM. left survey,408.4 panel schedule shall be explicit for each circuit
|
ELE05-01871
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 10:02:08 AM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 1:01:20 PM. no such address
|
ELE05-02076
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 10:00:46 AM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 12:53:13 PM. no such address
|
ELE05-02298
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 10:00:02 AM | A | PASS |
|
|
CONTACT IS PAUL; Phone #: ###-#### Internet Inspection Request from: Tyler Bowen ok to final
|
ELE05-01774
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 9:48:24 AM | A | NR |
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 12:56:50 PM. not ready, no fixtures, etc
|
ELE05-01502
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 9:44:31 AM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 12:51:58 PM. no access, no address
|
ELE05-01987
| Final | 7/11/2005 | 7/12/2005 | 7/12/2005 9:41:50 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 12:48:57 PM. told contr to verify panel sched, ok to final
|
ELE05-01640
| Electrical Rough-In | 7/8/2005 | 7/12/2005 | 7/11/2005 12:00:00 AM | A | CANC |
|
|
wall cover///donna; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa///cancel per Donna on 7/11/05 1:15pm BAS
|