Inspections for the day of: Tuesday, July 12, 2011.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC10-00868 Site Final7/12/20117/12/20117/12/2011 3:31:22 PMPPASS
site looks ok
ELE11-00609 Electrical Rough-In7/12/20117/12/20117/12/2011 3:29:40 PMPPASS
jason Phone #: ###-#### ceiling south of grid line f anop
ELE11-01523 Electrical Rough-In7/12/20117/12/20117/12/2011 3:28:28 PMPPASS
wire ac, home after 3:30 p.m. Phone #: ###-#### >> Inspection requested via web by PAT MILLER
ELE11-01523 Final7/12/20117/12/20117/12/2011 3:28:20 PMPPASS
wire ac, home after 3:30 p.m. Phone #: ###-#### >> Inspection requested via web by PAT MILLER
ELE11-01522 Electrical Rough-In7/12/20117/12/20117/12/2011 3:28:03 PMPPASS
wire air handler Phone #: ###-#### >> Inspection requested via web by PAT MILLER
ELE11-01522 Final7/12/20117/12/20117/12/2011 3:27:56 PMPPASS
wire air handler Phone #: ###-#### >> Inspection requested via web by PAT MILLER
ELE11-00914 Final7/11/20117/12/20117/12/2011 3:27:38 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Bryan Atkins ok card signed
ELE11-01521 Rough-In Permanent Service7/11/20117/12/20117/12/2011 12:53:40 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Andy Derrick p/s o/h rec. ok
ELE11-01525 Rough-In Permanent Service7/12/20117/12/20117/12/2011 12:07:33 PMAFAIL
Cal Phone #: ###-#### >> Inspection requested via web by cal crosby corr. & do not cover posted called box fill, outside boxes not flush with combustible material, 442.16(B)(4) range hood recept shall be on circuit all by itself protect all cables within 6ft of attic accesses, all recept outlet in laundry rm shall be on laundry circuit 314.17 NMB cable sheath shall extend into box 1/4", address nailplating and cables parallel
ELE11-01277 Electrical Rough-In7/11/20117/12/20117/12/2011 11:54:19 AMAPASS
UG cover and potting of light Phone #: ###-#### >> Inspection requested via web by Kevin Koomler
ELE11-01185 Permanent Service7/12/20117/12/20117/12/2011 11:54:03 AMAPASS
p/s u/g rec. ok
ELE11-01185 Final7/11/20117/12/20117/12/2011 11:53:38 AMACANC
request final see added p/s,, needs GEC to u/g water pipe, manufacture's instructions no load conductors shall exit top of panel

Contact: Anne Hasbrouck
Manager of Operations
ph. ###-#### press 0 for operator
call in advance please for appointment Phone #: ###-#### >> Inspection requested via web by jamie berg
ELE11-01512 Electrical Rough-In7/11/20117/12/20117/12/2011 11:51:34 AMAPASS
rough in on walls Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin
ELE11-01516 Temporary Service7/11/20117/12/20117/11/2011 4:16:08 PMAPASS
Thank you. Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe t/s u/g new ok