Inspections for the day of: Wednesday, July 12, 2017.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-01979 Final7/10/20177/12/20177/12/2017 2:31:31 PMPFAIL
Approved plans onsite.Tom, the homeowner, would appreciate a call before arrival, ###-####. Ryan King can answer questions, ###-####. Phone #: ###-#### Inspection requested via web by Ryan King 240.4D7 10awg copper 30amp max 40amp fuses installed
ELE17-01812 Final7/12/20177/12/20177/12/2017 1:18:47 PMPPASS
Phone #: ###-#### Inspection requested via web by Barbara Szurgot Final ok
ELE17-02223 Temporary Service7/12/20177/12/20177/12/2017 12:55:11 PMPPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE17-02181 Rough-In Permanent Service7/12/20177/12/20177/12/2017 12:35:48 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk rough in ok p/s u/g n ok
ELE16-02744 Electrical Rough-In7/12/20177/12/20177/12/2017 11:48:13 AMPPASS
Pool steel bonding connections for equipotental loop Phone #: ###-#### Inspection requested via web by Harley Woodward Corner bonding only ok to cover
ELE17-02083 Final7/11/20177/12/20177/12/2017 11:47:46 AMPPASS
Will call at noon to schedule a time to meet you onsite Phone #: ###-#### Inspection requested via web by Jesse Simpson Final ok
ELE17-02123 Final7/11/20177/12/20177/12/2017 11:47:30 AMAPASS
Phone #: ###-#### Inspection requested via web by Louis Keller Final ok
ELE17-02211 Electrical Rough-In7/12/20177/12/20177/12/2017 10:33:17 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M Rough in N wall only ok to cover
ELE17-02180 Final7/12/20177/12/20177/12/2017 9:46:35 AMAPASS
Existing data cables have been secured so they are not laying on t grid. Phone #: ###-#### Inspection requested via web by Kurt Carlson Corrections made final ok
ELE17-01318 Final7/11/20177/12/20177/12/2017 9:34:58 AMAFAIL
Joe-please call 30 minutes prior to meet Phone #: ###-#### 210.8A2 All garage receps shall be gfci protected.(GFCI RT of panel not hot, 2 other receps same wall not GFCI protected.) 110.3 Listed equipment shall be hooked up per manufacturer specs.( 3way dimmer for bed cans)
ELE17-02205 Final7/11/20177/12/20177/12/2017 9:05:57 AMAPASS
This is a Duplex, our work is in unit 1416, on the left. The Key is in the mailbox. Furnace is located in attic. Access is in same bedroom near panel. We installed a dedicated circuit for that, and installed a light, switch, plug, and disconnect switch.
Also installed a circuit with disconnect for the AC unit Phone #: ###-#### Inspection requested via web by Troy Cobb Final ok
ELE17-02001 Final7/11/20177/12/20177/12/2017 8:49:22 AMAPASS
Phone #: ###-#### Inspection requested via web by Bryan Atkins Final ok
ELE16-02745 Electrical Rough-In7/12/20177/12/20177/12/2017 12:00:00 AMAPASS
Drop cieilings in rooms 301-310, and 210- 204. Phone #: ###-#### Inspection requested via web by Harley Woodward 210-204 ok