ELE16-02185
| Electrical Rough-In | 7/13/2016 | 7/13/2016 | 7/13/2016 1:57:17 PM | P | FAIL |
|
|
call Josh for access Phone #: ###-#### 110.12 A. Unused openings shall be closed. Garage sub panel 300.4 A 1, NM Cable through bored holes less than 1 1/4in from face of framing member shall be protected Up bath/ down bed ceiling.
|
ELE16-01553
| Permanent Service | 7/13/2016 | 7/13/2016 | 7/13/2016 1:12:57 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jim Williams p/s o/h rec ok
|
ELE16-01183
| Electrical Rough-In | 7/13/2016 | 7/13/2016 | 7/13/2016 12:48:30 PM | P | PASS |
|
|
For access please call Johnathon 1/2 hr prior to inspection. ###-####.
Phone #: ###-#### Inspection requested via web by Terry Scott Kitchen countertop heat. Ok to cover
|
ELE15-03463
| Final | 7/13/2016 | 7/13/2016 | 7/13/2016 12:15:39 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI 680.12 Disconnect shall be outside of 5ft from waters edge, Hot tub.c 680.34 Recepticle shall be outside of 6ft from waters edge. Hot tub. Pantry outlets dont work
|
ELE16-02126
| Electrical Rough-In | 7/12/2016 | 7/13/2016 | 7/13/2016 10:49:53 AM | A | PASS |
|
|
Rough in inspection for OK to cover. Phone #: ###-#### Inspection requested via web by Kendra Lanham Partial cover only, All 2nd floor. 1st floor no Utility room, Basement no east room.
|
ELE16-02233
| Electrical Rough-In | 7/13/2016 | 7/13/2016 | 7/13/2016 10:05:47 AM | A | FAIL |
|
|
Someone should be on site all morning. Any questions please call Shaun ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman 210.52 C 4. Outlet within 24 in of sink
|
ELE16-00416
| Electrical Rough-In | 7/12/2016 | 7/13/2016 | 7/13/2016 9:41:42 AM | A | FAIL |
|
|
Todd Phone #: ###-#### Electrical contractor doing work without permit. Was instructed to pull Contractors permit. Homeowner pulled permit but did not do the wiring
|
ELE16-02229
| Temporary Service | 7/13/2016 | 7/13/2016 | 7/13/2016 9:33:54 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Zane Robertson Inspection cancelled from web by: Zane Robertson
|