PLM17-04019
| PLM-Aging Inspection | 7/13/2018 | 7/13/2018 | 7/17/2018 8:55:59 AM | | PASS |
|
|
|
PLM17-04014
| PLM-Aging Inspection | 7/13/2018 | 7/13/2018 | 7/13/2018 4:45:00 PM | | DEFR |
|
|
talked to Diana will sch
|
PLM17-03974
| PLM-Aging Inspection | 7/13/2018 | 7/13/2018 | 7/13/2018 4:41:09 PM | A | DEFR |
|
|
Left a phone message to follow up
|
PLM18-02954
| Water Heater Final | 7/13/2018 | 7/13/2018 | 7/13/2018 4:39:52 PM | P | PASS |
|
|
Please call Jim 30 min prior Phone #: ###-#### Inspection requested via web by Andrea Grigsby
|
PLM18-02954
| Final | 7/13/2018 | 7/13/2018 | 7/13/2018 4:39:36 PM | P | PASS |
|
|
Please call Jim 30 min prior Phone #: ###-#### Inspection requested via web by Andrea Grigsby
|
PLM18-02752
| Plumbing Rough-in | 7/12/2018 | 7/13/2018 | 7/13/2018 4:17:47 PM | P | FAIL |
|
|
I have completed the work and I''m pretty much ready for a final inspection, however, I would like to attend any observations the inspector might have. Since we are usually not available between 9 and 5, please call me at ###-#### about 30 minutes before arriving to be at home. Phone #: ###-#### Inspection requested via web by Nicole Yogerst The water heater will not meet the required clearances after the furnace is installed.
|
PLM18-01873
| Plumbing Rough-in | 7/13/2018 | 7/13/2018 | 7/13/2018 3:25:53 PM | P | PASS |
|
|
please call 15 mins ahead- Ronald Phone #: ###-####. Will add a cleanout on the wc vent
|
PLM18-02957
| Plumbing Rough-in | 7/13/2018 | 7/13/2018 | 7/13/2018 2:57:18 PM | P | FAIL |
|
|
Husband will be home all day. Phone #: ###-#### Inspection requested via web by Mike Freeman' Replace the black iron nipple on the cold water inlet at the ball valve and replace with an approved material. 2. Center the water heater in the pan for approved clearances. 3. Repair the leak at the ball valve on the cold water inlet.
|
PLM17-03675
| Plumbing Rough-in | 7/12/2018 | 7/13/2018 | 7/13/2018 2:31:21 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen. This is a final inspection. The floor drain in the garage must be have a trap primer and strainer or perm capped. This is the second failure notice for this item
|
PLM17-03783
| Plumbing Rough-in | 7/12/2018 | 7/13/2018 | 7/13/2018 2:27:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
PLM18-01276
| Final | 7/12/2018 | 7/13/2018 | 7/13/2018 12:02:33 PM | A | PASS |
|
|
#51408 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM18-02415
| Plumbing Rough-in | 7/12/2018 | 7/13/2018 | 7/13/2018 11:43:44 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Robert Frazier. 1. Drew an isometric drawing with fitting list to show all the changes. Needs a test
|
PLM18-01879
| Plumbing Rough-in | 7/12/2018 | 7/13/2018 | 7/13/2018 11:10:27 AM | A | PART |
|
|
RYAN IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER. The vents for the southwest corner are passed to above the ceiling grid.
|
PLM18-02919
| Water Heater Final | 7/11/2018 | 7/13/2018 | 7/13/2018 10:53:47 AM | A | CANC |
|
|
Please give a 30 minute window. Dennis Irvine Phone #: ###-#### Inspection requested via web by Tyler Collado The T&P drain cannot be attached with a flex connector. Hard pipe.
|
PLM18-01141
| Final | 7/12/2018 | 7/13/2018 | 7/13/2018 10:24:02 AM | A | PASS |
|
|
Call if you have any questions. Thank you, Phone #: ###-#### Inspection requested via web by Jennifer Alcala
|
PLM17-03715
| Sprinkler (Final) | 7/12/2018 | 7/13/2018 | 7/13/2018 10:10:16 AM | A | PASS |
|
|
McKenna Phone #: ###-####
|
PLM17-02407
| Final | 7/12/2018 | 7/13/2018 | 7/13/2018 10:08:17 AM | A | PART |
|
|
JOHN IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER. Final rough-in was completed on May 29, 2018. 1. All backflow assemblies in the existing building need cerifications due to out of date. 2. Expose the water service tracer wire at the building. 3. Verify all med gas certs have been forwarded to the City of Boise. Temp occ ok
|
PLM18-02938
| Water and/or Sewer | 7/12/2018 | 7/13/2018 | 7/13/2018 8:50:51 AM | A | PASS |
|
|
First Call
|
PLM18-02938
| DOC - Permit Finaled | 7/13/2018 | 7/13/2018 | 7/13/2018 8:50:36 AM | P | PASS |
|
|
sewer only
|
PLM18-02938
| Water and/or Sewer | 7/12/2018 | 7/13/2018 | 7/12/2018 4:25:10 PM | P | CANC |
|
|
rescheduled
|