FIR03-00711
| FIR-Aging Inspection | 7/14/2005 | 7/14/2005 | 7/15/2005 4:11:06 PM | | NR |
|
|
Harvy is to find out job status
|
FIR03-00678
| FIR-Aging Inspection | 7/14/2005 | 7/14/2005 | 7/15/2005 10:10:44 AM | | PASS |
|
|
|
FIR04-00743
| INSP-Sprinkler Rough-in/Hydro | 7/14/2005 | 7/14/2005 | 7/14/2005 4:19:22 PM | P | PASS |
|
|
Sprinkler piping is ok to cover.
|
BLD04-00300
| FIRE-Final Inspection | 7/14/2005 | 7/14/2005 | 7/14/2005 3:43:05 PM | P | PASS |
|
|
Paint curbs per sheet C-2, final fire alarm permit, provide one hour fire rated room per plans.
|
BLD04-01513
| FIRE-Final Inspection | 7/13/2005 | 7/14/2005 | 7/14/2005 12:06:04 PM | A | FAIL |
|
|
doug; Phone #: ###-#### Provide exit discharge lighting and approved hardware at the first floor southeast exterior door or remove hardware and exit sign. Provide fire extinguishers as marked in red on drawing sheets A1 and A2. Provide/repair exit signs and emergency lights as marked on sheets E1 and E2. Provide missing door hardware on all doors.
|
FIR05-00156
| INSP-Final Inspection | 7/14/2005 | 7/14/2005 | 7/14/2005 11:07:38 AM | P | CANC |
|
|
Troy, We would like to schedule an inspection for late this afternoon if at all possible. Around 3:00 would work the best for us, but whatever you could work in would be acceptable. Please call me at ###-####, so that I can have everyone onsite as needed. Thankd Troy. Jason; Phone #: ###-#### Internet Inspection Request from: Jason Minnick Inspection cancelled from web by: Jason Minnick
|
BLD05-01407
| FIRE-Final Inspection | 7/13/2005 | 7/14/2005 | 7/14/2005 9:38:40 AM | A | PASS |
|
|
Fire life safety finaled
|
FIR05-00317
| INSP-Final Inspection | 7/13/2005 | 7/14/2005 | 7/14/2005 9:38:11 AM | A | PASS |
|
|
Fire sprinkler pemit finaled
|
FIR05-00124
| INSP-Conference | 7/14/2005 | 7/14/2005 | 7/14/2005 12:00:00 AM | P | DONE |
|
|
I spoke to Dave with Debest about possible rated walls in the existing school. I referred him back to the architect. I also noted exposed wood including beams and 2x4's located above the ceiling that have no sprinkler protection.
|
FIR04-00718
| INSP-Conference | 7/14/2005 | 7/14/2005 | 7/14/2005 12:00:00 AM | P | DONE |
|
|
I met George with Romar to discuss the location of the a/v located in the middle of the ramp to the stage. The a/v in question is ok as installed 1" too low.
|
BLD05-01083
| FIRE-Conference | 7/14/2005 | 7/14/2005 | 7/14/2005 12:00:00 AM | P | DONE |
|
|
A duct smoke detector has been placed on the new hvac unit but has no wiring powering it or connecting it to the existing fire alarm system. Per contractor and plans the unit is under the 2000cfm limit and the duct smoke detector is not required.
|