Inspections for the day of: Monday, July 14, 2008.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-00153 Final7/14/20087/14/20087/14/2008 4:55:22 PMPPASS
Chris is the onsite contact his cell number is ###-####. Phone #: ###-#### Internet Inspection Request from: Shawna Gates ok to final, gave survey for sign at house panel, bond hot and cold water at heaters,install common trip breakers for furniture, signed occupancy card, could not enter esc data
ELE08-01900 Electrical Rough-In7/14/20087/14/20087/14/2008 4:04:08 PMPPASS
Dan Phone #: ###-#### corrections made, ok to pour concrete encased electrode and to cover u/g house to change house, no esc this project
ESC08-00268 General Inspection7/14/20087/14/20087/14/2008 3:37:22 PMPPASS
looked ok
ESC08-00522 General Inspection7/14/20087/14/20087/14/2008 3:36:24 PMPPASS
looked ok
ESC06-00711 General Inspection7/14/20087/14/20087/14/2008 3:34:37 PMPPASS
looked ok
ELE08-01837 Electrical Rough-In7/14/20087/14/20087/14/2008 3:33:31 PMPPASS
richard Phone #: ###-#### corrections made, ric ok
ELE08-00873 Electrical Rough-In7/14/20087/14/20087/14/2008 2:41:47 PMPFAIL
ted Phone #: ###-#### met owner, gave corrections, BCC all make-up shall be done, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, shall staple nm within 8" of box
ELE08-01864 Permanent Service7/11/20087/14/20087/14/2008 1:55:07 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Adam Staigle p/s o/h rec ok, no esc this project
ELE08-00143 Final7/14/20087/14/20087/14/2008 12:51:56 PMPPASS
Mike Phone #: ###-#### called contractor, ok to final
ELE08-01900 Electrical Rough-In7/11/20087/14/20087/14/2008 10:35:59 AMAPART
dan Phone #: ###-#### ok to cover inside building, shall clean up concrete encased electrode and recall and provide ground bar for panel, and change abrasion protection for gec, no esc this project
ELE08-01761 Electrical Rough-In7/11/20087/14/20087/14/2008 9:42:38 AMAPASS
Scheduled by a contractor via Hello! on 7/11/2008 at 5:28:51 PM. Contact: ###-####. corrections made, ric ok, no esc this project
ELE08-01922 Conference7/11/20087/14/20087/14/2008 9:06:46 AMADONE
jean Phone #: ###-#### reviewed requirements for concrete encased electrode, service and ri requirements, when to call for inspections etc., no esc this project
ELE08-01507 Electrical Rough-In7/14/20087/14/20087/14/2008 9:06:07 AMAPART
Hello we are ready for a ceiling grid inspection. Call if any problems or questions thanks. Phone #: ###-#### Internet Inspection Request from: Don Lustig called contractor, told builder ok to cover ceiling except 4 rows in main area. Electrical contractor shall strap mc within 12" of fixtures, 2 rows-center and south row, can see with few tiles left out- will call for am re-inspection, no esc this project
ELE08-01896 Final7/9/20087/14/20087/12/2008 6:28:55 PMACANC
Lock box code is 0345. Any questions or concerns please call MIKE AT ###-#### or Clay at ###-####. Thanks. Phone #: ###-#### Internet Inspection Request from: Clay Morgan Inspection cancelled from web by: Clay Morgan