FIR09-00255
| INSP-Sprinkler Rough-in/Hydro | 7/14/2009 | 7/14/2009 | 7/15/2009 12:52:57 PM | P | FAIL |
|
|
above ground hydro failed. No rough in inspection was performed
|
FIR09-00056
| FIR-Aging Inspection | 7/14/2009 | 7/14/2009 | 7/15/2009 12:24:08 PM | | NR |
|
|
wip
|
FIR09-00033
| INSP-Sprinkler Rough-in/Hydro | 7/10/2009 | 7/14/2009 | 7/15/2009 8:15:01 AM | A | PASS |
|
|
Rough-in complete on systems #7 and #8. Tim Frost verified that the 4x4 structural members will be considered obstructions and will need to be addressed on all systems. Also the ducting/roof penatrations will require sprinkler protection below them. This was addressed with Jeff with treasure valley fire.
|
BLD09-00427
| FIRE-Final Inspection | 7/13/2009 | 7/14/2009 | 7/15/2009 7:19:04 AM | P | FAIL |
|
|
Life safety will be ok to final when the project related fire alarm and fire sprinkler drawings have been modified to exclude sutie 325
|
FIR09-00396
| INSP-Final Inspection | 7/13/2009 | 7/14/2009 | 7/14/2009 3:33:05 PM | A | FAIL |
|
|
Piping is ok to cover. Can not give a final until the ceiling tile is installed.
|
FIR08-00830
| INSP-Sprinkler Rough-in/Hydro | 7/14/2009 | 7/14/2009 | 7/14/2009 3:32:16 PM | P | PASS |
|
|
The area under the stairs at the mechanical room/riser room can be covered.
|
BLD07-01910
| FIRE-Final Inspection | 7/13/2009 | 7/14/2009 | 7/14/2009 2:27:08 PM | A | FAIL |
|
|
The items needing correctlng for a life safety final include repairing all of the first floor exit signs and emergency lights as circled in red on the city approved plans. None of the second floor exit signs or emergency lights have been tested. All other life safety items are passed.
|
BLD09-00899
| FIRE-Final Inspection | 7/13/2009 | 7/14/2009 | 7/14/2009 2:02:29 PM | A | PART |
|
|
A temporary occupancy was given until the thumbturn is removed and lever hardware is provided on north warehouse exit door. Also I could not reach the sales area exit sign and emergency light test switches to see if they worked. They will need to be tested when I come back for the door hardware as per discussion with contractor.
|
BLD09-00537
| FIRE-Final Inspection | 7/14/2009 | 7/14/2009 | 7/14/2009 1:31:24 PM | P | FAIL |
|
|
Life safety in areas B and D is ok when the project related fire alarm for these areas is complete.
|
FIR09-00316
| INSP-Alarm Testing | 7/13/2009 | 7/14/2009 | 7/14/2009 1:30:23 PM | A | FAIL |
|
|
Todays inspection was for areas B and D. Alarms will be complete in these two areas when Alarmco finals their AES system and the samples tubes are installed correctly in the existing duct smoke detectors or verification is provided that this was an exceptable installation at the time the building was built.
|
BLD09-00274
| FIRE-Final Inspection | 7/14/2009 | 7/14/2009 | 7/14/2009 1:10:31 PM | P | PASS |
|
|
Life safety passed. Contractor to provide ADA approved single action hardware on the new office door as discussed.
|
BLD09-01105
| FIRE-Final Inspection | 7/14/2009 | 7/14/2009 | 7/14/2009 12:45:17 PM | P | PASS |
|
|
Life safety passed. The owner to install the address as discussed prior to the building inspection.
|
BLD09-00703
| FIRE-Final Inspection | 7/13/2009 | 7/14/2009 | 7/14/2009 12:09:45 PM | A | PASS |
|
|
life safety passed per stephanie cobbley
|
BLD09-00601
| FIRE-Final Inspection | 7/13/2009 | 7/14/2009 | 7/14/2009 10:44:58 AM | A | PASS |
|
|
James Phone #: ###-#### This permit has been passed previously by forrest france.
|
BLD06-01450
| FIRE-Final Inspection | 7/13/2009 | 7/14/2009 | 7/14/2009 10:20:03 AM | A | PASS |
|
|
Life safety passed.
|
FIR08-00438
| INSP-Final Inspection | 7/13/2009 | 7/14/2009 | 7/14/2009 10:18:50 AM | A | PASS |
|
|
Pemit finaled as per TIm Frost
|
FIR08-00439
| INSP-Final Inspection | 7/13/2009 | 7/14/2009 | 7/14/2009 10:18:25 AM | A | PASS |
|
|
Pemit finaled as per TIm Frost
|
FIR05-00698
| INSP-Alarm Testing | 7/13/2009 | 7/14/2009 | 7/14/2009 10:17:36 AM | A | PASS |
|
|
permit finaled
|
FIR05-00698
| INSP-Final Inspection | 7/14/2009 | 7/14/2009 | 7/14/2009 10:16:54 AM | P | PASS |
|
|
permit finaled
|
FIR09-00345
| INSP-Final Inspection | 7/13/2009 | 7/14/2009 | 7/14/2009 8:36:10 AM | A | FAIL |
|
|
The scope of work should actually state work in suites 315 and 325. As per telephone discussions between myself, Tim and Eddy with Western States plans need to be resubmitted deleting suite 325 from the scope of work since this area is going to be on hold. All work in suite 315 is complete and the permit can be finaled when the revised scope of work is issued.
|