Inspections for the day of: Tuesday, July 14, 2015.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-02160 Permanent Service7/14/20157/14/20157/14/2015 2:22:01 PMPCANC
Semsudin Phone #: ###-#### Needed rough in inspection
ELE15-02160 Electrical Rough-In7/14/20157/14/20157/14/2015 2:17:50 PMPPASS
Semsudin Phone #: ###-#### Permit for underground and service only. Underground from house to detached garage rough in ok cover.
ELE15-01926 Electrical Rough-In7/14/20157/14/20157/14/2015 1:53:30 PMPPASS
David Phone #: ###-#### Upstairs bed turning into a salon room. Rough in ok cover
ELE15-01809 Rough-In Permanent Service7/13/20157/14/20157/14/2015 12:29:22 PMPPASS
I''m needing a ceiling grid ; service inspection for the PM please. Phone #: ###-#### Inspection requested via web by Lynn Proctor Grid rough in ok cover p/s u/g n ok
ELE15-01430 Final7/13/20157/14/20157/14/2015 11:33:48 AMAFAIL
Phone #: ###-#### Inspection requested via web by daniel bibikov 110.3(B)- Light fixture over entry shall be installed to manufacturers listing. Fixture upside down.
210.52(C)(1)- Receptacle outlet shall be located with in 24 inches of edge of sink.
410.16(C)- Luminaire shall have 12 inches clearance from shelf in laundry closet.
ELE15-01916 Final7/13/20157/14/20157/14/2015 10:46:59 AMAPASS
call prior to arrival for access please. Phone #: ###-#### Inspection requested via web by Patrick Paz Final ok
ELE15-00922 Final7/14/20157/14/20157/14/2015 10:46:54 AMAFAIL
Garage code 6776 Phone #: ###-#### Inspection requested via web by Therrin Robertson corrections not complete. GFI 2nd to right of panel will not trip when tested by tester. 210.8- All 120 volt 15 and 20 amp receptacle outlets shall have GFCI protection.
ELE15-02035 Electrical Rough-In7/13/20157/14/20157/14/2015 10:14:45 AMAPASS
Roger- Phone #: ###-#### rough in ok cover
ELE15-01743 Final7/13/20157/14/20157/14/2015 9:54:21 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Traudt Final ok
ELE15-02137 Rough-In Permanent Service7/13/20157/14/20157/14/2015 9:34:26 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
ELE15-02071 Rough-In Permanent Service7/14/20157/14/20157/14/2015 9:11:02 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
ELE15-01898 Electrical Rough-In7/13/20157/14/20157/14/2015 8:54:15 AMAPASS
John Phone #: ###-#### Clessroom located at main entrance, turn right, room on left as you hit first corner. Changing lighting and exits as well. Switches and raised floor rough in ok cover
ELE12-01287 ELE-Aging Inspection7/14/20157/14/20157/14/2015 6:28:23 AM DONE
Waiting on owner