Inspections for the day of: Friday, July 14, 2017.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-02171 Final7/11/20177/14/20177/14/2017 3:06:43 PMPPASS
Please contact Mike at ###-#### for property access. They are there until 4pm Phone #: ###-#### Inspection requested via web by jamie berg
Final ok
ELE17-02171 Electrical Rough-In7/14/20177/14/20177/14/2017 2:48:08 PMPPASS
Please contact Mike at ###-#### for property access. They are there until 4pm Phone #: ###-#### Inspection requested via web by jamie berg
Rough in to new 60 amp circuit for AC unit at rear of building ok
ELE17-00800 Final7/14/20177/14/20177/14/2017 2:29:44 PMPCANC
Requesting an inspection after 3:30 pm. Call or text when in route as residence is occupied and I am not on site. Thank you. Phone #: ###-#### Inspection requested via web by Cortney Hopper
Called contact and left message unable to inspect due to time needed, not in area in late afternoon.
ELE17-02168 Rough-In Permanent Service7/10/20177/14/20177/14/2017 2:24:23 PMPPASS
Phone #: ###-#### Inspection requested via web by Zane Robertson
WUI zone soffit can fire barriers not done.
Remote hood control wire junction point has exposed conductors that shall be installed in a box or conduit as per 300.3. Access will be provided in fir down to enforce at final.
Interior Rough in ok cover p/s u/g n ok
ELE17-02246 Rough-In Permanent Service7/13/20177/14/20177/14/2017 1:20:30 PMPPASS
Phone #: ###-#### Inspection requested via web by Paula Gratiot
Wui Zone soffit can barriers not in place.
Interior only rough in ok cover
p/s u/g n ok
ELE17-01357 Final7/14/20177/14/20177/14/2017 11:17:07 AMAPASS
Final inspection for shed. I believe permit ELE17-01809 is ready for inspection as well. Contractor was waiting for me to build a wall between equipment area and bathroom. Phone #: ###-#### Inspection requested via web by Dean Perman
Final ok
ELE17-01809 Final7/14/20177/14/20177/14/2017 10:41:33 AMPPASS
Disconnecting means in place. Final ok
ELE17-02115 Final7/13/20177/14/20177/14/2017 10:40:55 AMAPASS
Phone #: ###-#### Inspection requested via web by Tyler Bowen Final ok
ELE14-02618 Final7/13/20177/14/20177/14/2017 10:03:39 AMAFAIL
There should be someone there. There is a lock box just in case 4320. Steve would be your contact ###-####. If you have any questions please call Clay ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clay Morgan
240.4- Max overcurrent device for 14 gauge wire 15 amps. 20 amp installed on garage circuit.
250.53- Grounding electrode conductor and interbond bar shall be secured to structure.
422.30- A disconnecting means shall be provided for water heater. 110.25 Lockout acceptable.
ELE17-01337 Electrical Rough-In7/13/20177/14/20177/14/2017 9:28:33 AMAPASS
We are requesting an underground inspection for tomorrow morning. Our contact is Rick @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
Contractor providing 2nd concrete encased for pool equipment. Equipment grounding conductor shall be minimum of #4 to this room to be added to grounding electrode system. Rough in ok cover
ELE17-02198 Permanent Service7/13/20177/14/20177/14/2017 8:39:42 AMAPASS
Phone #: ###-#### Inspection requested via web by Louis Keller
200 amp service on pole located eastside of back yard. p/s o/h n ok
ELE15-03035 Final7/13/20177/14/20177/14/2017 7:27:04 AMPCANC
Contact Paul at ###-####. Thank You Phone #: ###-#### >> Inspection requested via web by Steve Blackmer Inspection cancelled from web by: Steve Blackmer