Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM02-01617 Final7/12/20027/15/20027/15/2002 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 07/12/2002 at 15:25:43. Contact: ###-####.
PLM02-01744 Final7/15/20027/15/20027/15/2002 12:00:00 AMANR
Scheduled by a contractor via Hello! on 07/15/2002 at 07:29:22. Contact: ###-####. called in the wrong inspection 7/15/2002 9:16:25 AM
PLM02-01789 Plumbing Rough-in7/15/20027/15/20027/15/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 07/15/2002 at 07:42:25. Contact: ###-####.
PLM02-00777 Final7/15/20027/15/20027/15/2002 12:00:00 AMPFAIL
Scheduled by a contractor via Hello! on 07/15/2002 at 09:00:33. Contact: ###-####. test filtered water r.p., lable filtered water r.p., identify non-potable water at fish island"CAUTION: NON-POTABLE WATER, DO NOT DRINK". provide pvbs or spill resistant pvbs at all dog wash faucetts, at the fish island sinks a shutoff valve is required at each fixture, the trap primer shutoff valve behind the fish tanks must be acessable from this space, plug the fip at the cold water supply to the water heater, remove the tee upstream of the premise dcva. 7/15/2002 2:51:30 PM
PLM02-01653 Final7/15/20027/15/20027/15/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 07/15/2002 at 09:01:26. Contact: ###-####.
PLM02-02085 Plumbing Rough-in7/15/20027/15/20027/15/2002 12:00:00 AMPPASS
###-####
PLM02-02076 Water and/or Sewer7/15/20027/15/20027/15/2002 12:00:00 AMPNR
Scheduled by a contractor via Hello! on 07/15/2002 at 10:02:34. Contact: ###-####. wrong permit number phoned in by debest, no inspection request. 7/15/2002 3:21:28 PM