Inspections for the day of: Wednesday, July 15, 2009.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC07-01018 General Inspection7/15/20097/15/20097/15/2009 4:02:16 PMPPASS
seemed ok
ESC09-00362 General Inspection7/15/20097/15/20097/15/2009 4:01:20 PMPPASS
looked ok
ELE08-03244 Final7/15/20097/15/20097/15/2009 4:00:46 PMPCANC
JAMES CLIFF - CALL 30 TO 45 MINUTES EARLY TO OBTAIN ACCESS Phone #: ###-#### Internet Inspection Request from: Randy Vail called , left message no call back or response, contractor will have to make available later
ELE09-00172 Final7/14/20097/15/20097/15/2009 3:59:14 PMPPASS
Mitch Phone #: ###-#### ok to final, no esc this project
ELE08-03233 Conference7/15/20097/15/20097/15/2009 3:58:04 PMPDONE
met contractor to discuss procedure for starting final inspections, and process for t/o for buildings, met with Drew, Mike, Justin, and Stu, and 412
ELE09-01142 Electrical Rough-In7/15/20097/15/20097/15/2009 1:48:23 PMPPASS
Dave Phone #: ###-#### met contractor, ric ok, no esc this project
ELE09-01142 Permanent Service7/15/20097/15/20097/15/2009 1:43:34 PMPPASS
p/s o/h rec ok, see 2 ground rods at final, no esc this project
ELE09-01256 Permanent Service7/14/20097/15/20097/15/2009 1:25:58 PMPPASS
robert Phone #: ###-#### p/s u/g rec ok, no esc this project
ELE09-00455 Electrical Rough-In7/15/20097/15/20097/15/2009 12:39:36 PMPPASS
Scheduled by a contractor via Hello! on 7/15/2009 at 9:57:00 AM. Contact: ###-####. ok to cover ceilings only, no esc this project
ELE09-01225 Permanent Service7/9/20097/15/20097/15/2009 10:49:45 AMPPASS
bud Phone #: ###-#### p/s o/h rec ok, no esc this project
ELE09-01238 Final7/14/20097/15/20097/15/2009 10:35:27 AMAPASS
Homeowner is Kendra Falen, we tagged the water pipe near crawl as in enters the house, bonded hot and cold at water heater, the garage addition will be permitted called, ok to final, no esc this projectseparately. Phone #: ###-#### Internet Inspection Request from: Andy Derrick
ELE09-01247 Electrical Rough-In7/14/20097/15/20097/15/2009 10:00:30 AMAFAIL
Internet Inspection Request from: jason shifflett no number left, called numbers, no response, bad contacts till they call in number, left correction notice,NEC 250.52(A)(3) shall provide concrete encased electrode, 230.66 service equipment shall be marked to identify as being suitable for use as service equipment, 110.12(A) unused openings shall be closed, 314.27)A) shall supply boxes for luminaires, Note: no underground seen
ELE09-00896 Final7/14/20097/15/20097/15/2009 9:28:40 AMAPART
this is ready call if you have any questions thanks Phone #: ###-#### Internet Inspection Request from: Don Lustig ok to final, signed t/o card, need to come back once furniture is final assembled 1 room only, no esc this project
ELE08-03244 Final7/14/20097/15/20097/15/2009 8:23:07 AMANH
MITCH PAGE -
OFFICE HAS BEEN REMOVED, OTHER DEFICIENCIES HAVE BEEN CORRECTED Phone #: ###-#### Internet Inspection Request from: Randy Vail called contractor, people moved out, told to call when access available, fee due, left card, no esc this project
ELE09-01217 Final7/14/20097/15/20097/15/2009 8:05:05 AMAPASS
Please provide final inspection. Phone #: ###-#### Internet Inspection Request from: Spencer Mclean ok to final, no occupancy card to sign, only bring up to 08 NEC new work not started, or partially done