Inspections for the day of: Wednesday, July 15, 2015.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC14-00360 General Inspection7/15/20157/15/20157/16/2015 8:48:57 AM PASS
ESC14-00299 Conference7/15/20157/15/20157/15/2015 4:40:49 PMPDONE
Onsite meeting with Westminster Homes project managers to discuss significant hillside erosion and sediment runoff issues. Part of issue is the intensity of storm received and the home does not yet have permanent stormwater drainage facilities (gutters, injection well)

Corrections discussed:
1. Clean gutter and DI bag out on Selkirk
2. Clean loose dirt and sand on top of and around retaining wall.
3. Install sediment control wattles (trenched in) along the length of back of the house and at the discharge point to neighbors (to the southeast)
4. Dig sediment basin/trench on uphill side of retaining wall.
5. Empty out trash container

Work will begin on corrections today, all corrections due by next Tuesday morning.
ESC15-00545 Random Inspection7/15/20157/15/20157/15/2015 4:34:54 PMPPASS
No activity at Union Square commercial site, though it has been graded. BMPs installed, permit sign posted. No discharges, no significant trackout, and no fugitive dust observed at time of inspection.
ESC15-00559 Complaint Inspection7/15/20157/15/20157/15/2015 4:18:31 PMPFAIL
Stockpile placed on edge of property. Some spill over into street and gutter needs to be removed/cleaned and stockpile should be moved further into the property or offsite.

Homeowner RP stated he will clean it up and the stockpile will be removed this week.
ESC15-00692 Site Preparation7/14/20157/15/20157/15/2015 3:18:50 PMACANC
Adam Phone #: ###-####

will visit site tomorrow. approved to start
ESC14-01139 General Inspection7/15/20157/15/20157/15/2015 3:14:00 PM PASS
ESC14-01138 General Inspection7/15/20157/15/20157/15/2015 3:13:50 PM PASS
ESC13-01279 General Inspection7/15/20157/15/20157/15/2015 2:02:22 PM PASS
ESC14-00299 Complaint Inspection7/15/20157/15/20157/15/2015 10:36:36 AMAFAIL
Hillside erosion with rills and gullies created. Bottom of slope hillside had water running over top to neighbors on Curling.

Contacted RP/GC and working with PW civil engineer and geotech engineer. Does not appear any permanent stormwater features are installed.

Will need to repair rills/gullies and install temporary erosion and sediment containment BMPs

Case is pending. Unable to reach Charlie with Westminster on first attempt.
ESC15-00605 Site Preparation7/14/20157/15/20157/15/2015 10:06:04 AMAPASS
Terry Phone #: ###-####

Permit sign posted. Homeowner RP supervising project. City PW has inspected and approved. Working in cooperation with neighbor to secure wall between the two backyards. Work area surrounded by vegetative buffer/landscaped yard.

Approved.
ESC14-01033 Aging Inspection7/15/20157/15/20157/15/2015 9:12:22 AM PASS