Inspections for the day of: Thursday, July 16, 2009.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-04036 ELE-Aging Inspection7/16/20097/16/20097/17/2009 3:57:50 PM DONE
no activity, suc
ESC08-00457 General Inspection7/16/20097/16/20097/16/2009 4:25:43 PMPPASS
looked ok
ESC08-00995 General Inspection7/16/20097/16/20097/16/2009 3:59:09 PMPPASS
looked ok, yard not done
ESC09-00362 General Inspection7/16/20097/16/20097/16/2009 3:58:17 PMPPASS
looked ok, trench open but being closed today
ESC07-01432 General Inspection7/16/20097/16/20097/16/2009 3:57:22 PMPPASS
seemed ok
ELE08-02423 Final7/16/20097/16/20097/16/2009 3:56:06 PMPCANC
JASON BLDG 3 L1 UNITS D EAST, D WEST & D1 Phone #: ###-#### Internet Inspection Request from: Sean DeLacy called electrician for security code, found doors locked, could not find any people, called contractor to re-schedule
ELE09-01268 Rough-In Permanent Service7/16/20097/16/20097/16/2009 3:54:40 PMPPASS
Thanks! Phone #: ###-#### Internet Inspection Request from: Darryn Coburn ric ok, p/s u/g n ok
ELE09-01273 Temporary Service7/16/20097/16/20097/16/2009 3:13:01 PMPPASS
Thanks! Phone #: ###-#### Internet Inspection Request from: Darryn Coburn t/s u/g n ok, no esc this project
ELE09-01272 Temporary Service7/16/20097/16/20097/16/2009 2:40:35 PMPPASS
Thanks! Phone #: ###-#### Internet Inspection Request from: Darryn Coburn t/s u/g n ok, no esc this project
ELE09-01185 Electrical Rough-In7/15/20097/16/20097/16/2009 2:01:22 PMPPART
Contact: John Stebly Phone #: ###-#### Internet Inspection Request from: Deb Gooden walls anop only ok to cover, no esc this project
ELE09-00910 Electrical Rough-In7/15/20097/16/20097/16/2009 1:07:33 PMPFAIL
Call Ray for access and description of
work to be inspected at ###-#### Internet Inspection Request from: Dave Friend called contractor, and structural, left correction notice, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(A) shall provide receptacle spacing per code, 225.36 disconnect shall be suitable for service equipment, 250.32 shall provide grounding electrode system, BCC all underground shall be inspected before cover, approved set of plans shall be on job, all make-up shall be done, shall not cover any wiring befor inspection, shall obtain building and plumbing permits, no esc this project
ELE09-01268 Final7/16/20097/16/20097/16/2009 11:17:35 AMPCANC
Thanks!!! Phone #: ###-#### Internet Inspection Request from: Darryn Coburn Inspection cancelled from web by: Darryn Coburn
ELE09-00926 Final7/15/20097/16/20097/16/2009 10:53:45 AMAPASS
Jim is the contact his no.is ###-####. Phone #: ###-#### Internet Inspection Request from: Shawna Gates ok to final up and down, no esc this project
ELE09-00908 Final7/15/20097/16/20097/16/2009 10:48:17 AMAPASS
Jim is the contact his no. is ###-####. Phone #: ###-#### Internet Inspection Request from: Shawna Gates ok to final up and down, no es this project
ELE09-00902 Final7/15/20097/16/20097/16/2009 10:47:44 AMAPASS
Jim is the contact his no. is ###-####. Thank you. Phone #: ###-#### Internet Inspection Request from: Shawna Gates ok to final up and down, no esc this project
ELE09-00925 DOC - Permit Finaled7/16/20097/16/20097/16/2009 10:33:38 AMPPASS
ELE09-01247 Electrical Rough-In7/16/20097/16/20097/16/2009 10:06:29 AMAPASS
dave-###-#### corrections made, ric ok, u/g house to garage ok to cover, single 15a gfci circuit to garage, 1" sleeve for future phone
ELE09-01249 Final7/15/20097/16/20097/16/2009 9:29:42 AMAPASS
PLease call at least 30 mins prior so he can arrange access-Pat Phone #: ###-#### ok to final, no esc this project
ELE08-02062 Final7/15/20097/16/20097/16/2009 9:07:04 AMAPASS
Geo Phone #: ###-#### ok to final
ELE08-02536 Electrical Rough-In7/16/20097/16/20097/16/2009 8:31:38 AMAPASS
Requesting a soffit inspection for the East and South entry. Phone #: ###-#### Internet Inspection Request from: Dan Hardisty east and south soffits ok to cover
ELE09-01114 Conference7/16/20097/16/20097/16/2009 8:17:13 AMADONE
Please contact John Campbell for a conference. Phone #: ###-#### Internet Inspection Request from: Sarah Bastian talked about services and locations for waiting areas for shuttle people, no esc this project