Inspections for the day of: Tuesday, July 17, 2007.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-02500 Temporary Service7/17/20077/17/20077/17/2007 4:27:50 PMPPASS
temp power pole, any questions call Tate @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose
t/s o/h new ok
ELE07-02509 Temporary Service7/17/20077/17/20077/17/2007 4:01:43 PMPPASS
daryl; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
t/s o/h new ok
ELE07-02510 Temporary Service7/17/20077/17/20077/17/2007 4:01:23 PMPPASS
daryl; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
t/s o/h new ok
ELE07-00162 Final7/16/20077/17/20077/17/2007 3:34:44 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Bryan Atkins ok card signed
ELE07-00161 Final7/16/20077/17/20077/17/2007 3:34:22 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Bryan Atkins ok card signed
ELE07-02420 Permanent Service7/17/20077/17/20077/17/2007 2:54:09 PMPCANC
Final on Permanent service. Randy ###-####, thanks Phone #: ###-#### Internet Inspection Request from: Randy Fletcher
ELE07-02420 Final7/17/20077/17/20077/17/2007 2:54:04 PMPPASS
Final on Permanent service. Randy ###-####, thanks Phone #: ###-#### Internet Inspection Request from: Randy Fletcher ok
ELE07-02380 Electrical Rough-In7/17/20077/17/20077/17/2007 2:36:38 PMPPASS
TOM Phone #: ###-#### corr. made Egrid , bond, potting ok
ELE07-02516 Electrical Rough-In7/17/20077/17/20077/17/2007 2:21:45 PMPPASS
john Phone #: ###-#### r/i ok
ELE07-01367 Electrical Rough-In7/17/20077/17/20077/17/2007 1:27:00 PMPFAIL
david - pls call 30 mins prior; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang 250.148 terminate all equip grds together at boxes, 250.92 terminate bond to neutral bus not equip grd bus, 200.7(C) shall ID neutral used as ungrouned it's entire length334.23 protect cables attic accesses, 210.52(B) remove vacuum form SABC in din rm, 110.2 jtub not listed could not locate corr. posted called, do not cover posted
ELE07-02245 Electrical Rough-In7/12/20077/17/20077/17/2007 12:10:14 PMPPART
Underground. 1st thing in the afternoon, if possible, so they can backfill. Thank you. Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton u/g for lights ok
ELE07-02038 Final7/16/20077/17/20077/17/2007 10:30:13 AMAPASS
Please Call Chad at the above number before inspection. The home owner should be at home as well. Phone #: ###-#### Internet Inspection Request from: Todd Sellman ok
ELE07-02313 Electrical Rough-In7/17/20077/17/20077/17/2007 9:57:25 AMAPASS
shop interior panel Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer added subpanel ok
ELE07-02498 Conference7/16/20077/17/20077/17/2007 9:18:25 AMADONE
greg Phone #: ###-#### phone conference ok
ELE07-01362 Final7/16/20077/17/20077/17/2007 9:03:09 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Tracy Robertson corr called 110.26(F)(2) remove phone and tv from beloww p/s
ELE07-01551 Rough-In Permanent Service7/16/20077/17/20077/17/2007 8:08:10 AMAFAIL
joe Phone #: ###-#### p/s note all grds and bonds shall be installed before p/s can be tagged
ELE07-02009 Permanent Service7/16/20077/17/20077/17/2007 7:19:26 AMACANC
inspect permanent service on west side of building. need to get it heated up! thanks
Randy Phone #: ###-#### Internet Inspection Request from: Loren Ramsey Inspection cancelled from web by: Loren Ramsey
ELE07-02495 Rough-In Permanent Service7/16/20077/17/20077/16/2007 2:16:12 PMAPASS
chris Phone #: ###-#### r/i p/s u/g new ok
ELE07-02494 Rough-In Permanent Service7/16/20077/17/20077/16/2007 2:15:48 PMAPASS
chris Phone #: ###-#### r/ip/s u/g new ok