ELE07-02173
| Electrical Rough-In | 7/17/2007 | 7/17/2007 | 7/18/2007 12:47:11 PM | P | FAIL |
|
|
randy Phone #: ###-#### called, left message, left corr notice, nec 210.52 shall provide recpts at front and rear of dwelling, in hall over 10' long, in walls over 2', within 6' of room entry and not over 12' apart along wall line, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 314.17 shall staple nm cable within 8" or 12" of appropriate boxes, 300.14 shall provide 6" free conductor length at boxes, BCC no violations shall be retained
|
ELE07-01454
| Electrical Rough-In | 7/17/2007 | 7/17/2007 | 7/18/2007 9:44:13 AM | A | PASS |
|
|
Please call the office for any issues. Internet Inspection Request from: Daniel Gamboa called elect, met elect, ric ok
|
ELE07-01027
| ELE-Aging Inspection | 7/17/2007 | 7/17/2007 | 7/18/2007 9:26:23 AM | | NR |
|
|
looked at signs, suc
|
ELE07-02499
| Conference | 7/16/2007 | 7/17/2007 | 7/17/2007 3:58:28 PM | P | DONE |
|
|
sam- ###-####--call 1st before insp talked about new service, grounding, clearances, when to call, conduit fill
|
ELE06-03761
| Final | 7/16/2007 | 7/17/2007 | 7/17/2007 3:28:43 PM | P | PASS |
|
|
totally forgot to recall inspection job finished meter Labled and panel labled Phone #: ###-#### Internet Inspection Request from: Don Lustig ok to final
|
ELE07-02302
| Electrical Rough-In | 7/16/2007 | 7/17/2007 | 7/17/2007 3:07:56 PM | P | PART |
|
|
Contact: Steve Hess - U/G inspection please Phone #: ###-#### Internet Inspection Request from: Deb Gooden stem walls E&F and u/g for C&D ok to pour
|
ELE07-00940
| Electrical Rough-In | 7/17/2007 | 7/17/2007 | 7/17/2007 2:25:49 PM | P | NR |
|
|
MICHAEL nOTE: PLEASE 1/2 HR PRIOR Phone #: ###-#### met owner, still needs to provide tails for make-up, flush boxes, will do concrete for service pipe later, will call for ri except for riser
|
ELE06-01319
| Electrical Rough-In | 7/17/2007 | 7/17/2007 | 7/17/2007 2:00:26 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Justin Yount ok to cover main level only
|
ELE07-00791
| Final | 7/17/2007 | 7/17/2007 | 7/17/2007 1:10:03 PM | P | PASS |
|
|
duane ; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang corr made, ok to final
|
ELE06-03451
| Final | 7/17/2007 | 7/17/2007 | 7/17/2007 12:29:55 PM | P | PASS |
|
|
ok to final
|
ELE07-02508
| Electrical Rough-In | 7/17/2007 | 7/17/2007 | 7/17/2007 12:28:30 PM | P | PASS |
|
|
Installed a total of 4 new circuits: 2 on west wall and 2 on the north and east walls. See Scott onsite for the tour.This is in Elms Park Mini-Mall, Chicago Connection. Tech: James @ ###-####.Thanks!!!! Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ric ok
|
ELE07-02508
| Final | 7/17/2007 | 7/17/2007 | 7/17/2007 12:25:48 PM | P | PASS |
|
|
Installed a total of 4 new circuits: 2 on west wall and 2 on the north and east walls. See Scott onsite for the tour.This is in Elms Park Mini-Mall, Chicago Connection. Tech: James @ ###-####.Thanks!!!! Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok to final
|
ELE06-03451
| Final | 7/16/2007 | 7/17/2007 | 7/17/2007 12:11:12 PM | P | NH |
|
|
sarah Phone #: ###-#### called, left message, left card
|
ELE07-02460
| Temporary Service | 7/16/2007 | 7/17/2007 | 7/17/2007 10:56:56 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 7/16/2007 at 2:58:17 PM. Contact: ###-####. corr made, t/s u/g n ok
|
ELE07-01454
| Final | 7/16/2007 | 7/17/2007 | 7/17/2007 10:35:20 AM | A | CANC |
|
|
Please call the office for any issues. Internet Inspection Request from: Daniel Gamboa wrong type request, see ri
|
ELE07-02487
| Electrical Rough-In | 7/17/2007 | 7/17/2007 | 7/17/2007 9:53:00 AM | A | PASS |
|
|
kitchen, dining, entry work, corrections made. Phone #: ###-#### Internet Inspection Request from: Monty Adkinson corrections made, ric ok
|
ELE07-02259
| Final | 7/16/2007 | 7/17/2007 | 7/17/2007 9:31:57 AM | A | PASS |
|
|
rocky - after 9:00 am please Phone #: ###-#### corrections made, no elect occ card to sign, ok to final
|
ELE07-00773
| Extend Permit 180 days | 7/16/2007 | 7/17/2007 | 7/17/2007 9:05:28 AM | A | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk wrong type request, see rip
|
ELE07-00773
| Rough-In Permanent Service | 7/17/2007 | 7/17/2007 | 7/17/2007 9:05:11 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk ric ok, called contr, p/s u/g n ok
|
ELE07-01526
| Electrical Rough-In | 7/16/2007 | 7/17/2007 | 7/17/2007 8:31:25 AM | A | PASS |
|
|
please inspect kitchen rough in. Bill and Mary Jo are the residents at this house. call Loren Ramsey at ###-#### with any questions. thanks! Phone #: ###-#### Internet Inspection Request from: Loren Ramsey called contr, ric kitchen only ok
|