Inspections for the day of: Thursday, July 17, 2008.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC07-00787 General Inspection7/17/20087/17/20087/17/2008 3:52:13 PMPPASS
looked ok
ESC08-00336 General Inspection7/17/20087/17/20087/17/2008 3:50:36 PMPPASS
looked ok
ESC08-00439 General Inspection7/17/20087/17/20087/17/2008 3:49:37 PMPPASS
looked ok
ESC08-00578 General Inspection7/17/20087/17/20087/17/2008 3:48:46 PMPPASS
looked ok
ELE08-00106 Final7/17/20087/17/20087/17/2008 3:47:22 PMPPASS
dan Note: call dan for access Phone #: ###-#### ok to final, left survey, NEC 422.11(A) a/c branch corcuit shall be protected according to marked nameplate
ELE08-01787 Electrical Rough-In7/16/20087/17/20087/17/2008 3:02:26 PMPFAIL
Scheduled by a contractor via Hello! on 7/16/2008 at 9:47:22 PM. Contact: ###-####. called, left message, left correction notice, NEC 330.30 mc cable shall be secured within 12" of box, 330.17 mc cable shall be protected in accordance with 300.4(A), (C), & (D) where installed through framing members (1/14"), BCC mc cable shall not be run in valley of steel studs
ELE08-01976 Permanent Service7/17/20087/17/20087/17/2008 2:15:40 PMPFAIL
ray Phone #: ###-#### called, left correction notice, NEC 250.24 gec shall not splice thru enclosure, but be connected directly to each service point
ELE08-01976 Electrical Rough-In7/17/20087/17/20087/17/2008 1:31:12 PMPFAIL
ray Phone #: ###-#### called, left correction notice, 110.14(A) terminal connections shall ensure a thoroughly good connection (garage), 334.30 nm cable shall not be stapled on edge, and be secured within 12" of panel, 300.4(A)(1) edge of bored holes shall be 1 1/4" from edge of framing member, 210.52 (A)(1) receptacles shall be installed such that no point along floor line is over 6' from a receptacle outlet (upper bedroom, nw )
ELE08-01650 Electrical Rough-In7/17/20087/17/20087/17/2008 12:45:08 PMPPART
underground - contact is Toby Groves ###-#### Phone #: ###-#### Internet Inspection Request from: Debby Ellis central west u/g south of school ok to cover
ELE07-03153 Final7/16/20087/17/20087/17/2008 10:11:31 AMAPASS
John- call 30 min prior to going Phone #: ###-#### ok to final
ELE06-02073 Conference7/16/20087/17/20087/17/2008 9:49:16 AMADONE
brian Phone #: ###-#### looked at progression of construction, told owner to call for ri inspection, looked at plans, told what we would need to look at
ELE08-01312 Final7/16/20087/17/20087/17/2008 9:08:19 AMANH
Homeowners are supposed to be home till 10. Phone #: ###-#### Internet Inspection Request from: Cevyn Recla called, left message, left card, fee due, no esc this project
ELE08-01967 Conference7/16/20087/17/20087/17/2008 8:39:22 AMADONE
Jim is the contact his cell number is ###-####. Phone #: ###-#### Internet Inspection Request from: Shawna Gates talked about mc cable in chase with low voltage to point of sale for about 20',said had to ground chase, no esc this project
ELE08-01029 Electrical Rough-In7/16/20087/17/20087/17/2008 8:16:07 AMACANC
Bud- ceiling Phone #: ###-#### wrong type inspection, see part final
ELE08-01029 Final7/17/20087/17/20087/17/2008 8:15:53 AMAPART
Bud- ceiling Phone #: ###-#### ok to part final ceiling anop