Inspections for the day of: Friday, July 17, 2020.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-02675 Final7/17/20207/17/20207/17/2020 3:08:03 PMPCANC
Please call Shari Nova prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- due t COVID 19 can not enter inti occupied dwellings- only access to backyard was thru town home- no exterior gates
MEC20-02831 Final7/13/20207/17/20207/17/2020 1:21:03 PMPCANC
Please call Nancy on your way ###-#### Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks
MEC20-02950 Pressure Test7/17/20207/17/20207/17/2020 1:11:37 PMPFAIL
pressure whiteness gas line to package unit on roof. Phone #: ###-#### Inspection requested via web by David Dixon-
1- both penetrations thru wall at meter and on roof need 10 mil tape installed-
2- vertical csst in wall need supports removed needs to be free floating
3- need csst approved nail plates in exterior wall on horizontal gas piping
4- retest whole system once corrections are made
MEC20-02893 Final7/17/20207/17/20207/17/2020 11:36:59 AMAPASS
electric funace a/c coil co locking caps ok- visual inspection thru window
MEC20-02679 Final7/17/20207/17/20207/17/2020 11:27:30 AMACANC
already completed reschedule by accident
MEC20-02922 Pressure Test7/16/20207/17/20207/17/2020 11:03:14 AMACANC
Add rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- see note 2 on correction notice
MEC20-02922 Rough-in7/16/20207/17/20207/17/2020 11:02:24 AMAFAIL
Add P test Phone #: ###-#### Inspection requested via web by Joe Taylor-
1- insulation shield for water heater needs minimum 1" clearance and tabs bent in laying against b vent
2- gas stub out to gas meter needs extended and retest or readjust hanger in wall
3- dryer duct to termination box needs sealed
4- vertical csst gas ping in wall at range shall not be secured to structure shall be free floating
5- need city approved man j onsite for inspection none found
6- dryer duct at ceiling needs notch bigger pipe is deformed needs to maintain round and nail plate installed other side
7- line set needs ran on R/I inspection

left notice front entry window
MEC19-03696 Final7/16/20207/17/20207/17/2020 10:30:39 AMAPASS
Inspection requested via web by Brian Preece- fireplace final ok- no mantel
MEC20-02539 Final7/15/20207/17/20207/17/2020 10:00:09 AMAFAIL
Ac Change inspection
for access please call homeowner Martha at ###-#### Phone #: ###-#### Inspection requested via web by David Nelson- a/c coil co locking caps ok- need right size fuses has 20 needs 15 max- send pic for reinspect
MEC20-02898 Final7/16/20207/17/20207/17/2020 9:16:51 AMACANC
Furnace in garage. Homeowner Jim Wheeler ###-#### Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
MEC20-02938 Final7/16/20207/17/20207/17/2020 9:15:00 AMAFAIL
please contact homeowner when in route Nick Jones ###-#### Phone #: ###-#### Inspection requested via web by Chris Wieboldt- furnace a/c coil co ok- need locking caps on a/c service ports- send pic for reinspect
MEC20-02679 Final7/16/20207/17/20207/17/2020 8:43:51 AMAPASS
please call before coming- Maris *can be Virtual* Phone #: ###-####- final ok- pics sent via text on wet switch
MEC20-02796 Final7/16/20207/17/20207/17/2020 8:31:52 AMACANC
FINAL TEST PRESSURE FOR ADDED ISOLATION VALVES. Phone #: ###-#### Inspection requested via web by RM Mechanical- scheduled as conference
MEC20-02796 Conference7/17/20207/17/20207/17/2020 8:30:35 AMPDONE
FINAL TEST PRESSURE FOR ADDED ISOLATION VALVES. Phone #: ###-#### Inspection requested via web by RM Mechanical- discussed pressure testing and locations
MEC20-02535 Rough-in7/16/20207/17/20207/17/2020 8:22:39 AMACANC
call andrey he will meet you on the job Phone #: ###-#### >> Inspection requested via web by Oleg Chervak Inspection cancelled from web by: Oleg Chervak
MEC20-02534 Rough-in7/16/20207/17/20207/17/2020 8:22:21 AMACANC
call andrye he will meet you on the job Phone #: ###-#### >> Inspection requested via web by Oleg Chervak Inspection cancelled from web by: Oleg Chervak
MEC20-02533 Rough-in7/16/20207/17/20207/17/2020 8:22:12 AMACANC
call me i will meet you on the job--andrey Phone #: ###-#### >> Inspection requested via web by Oleg Chervak Inspection cancelled from web by: Oleg Chervak
MEC20-02532 Rough-in7/16/20207/17/20207/17/2020 8:22:05 AMACANC
call me i will me you on the job Phone #: ###-#### >> Inspection requested via web by Oleg Chervak Inspection cancelled from web by: Oleg Chervak
MEC19-02803 Mec-Aging Inspection7/17/20207/17/20207/17/2020 8:07:38 AM CANC
permit expired
MEC19-02803 DOC - Permit Expired7/17/20207/17/20207/17/2020 8:07:28 AMAPASS
permit expired no call no activity
MEC19-05616 Mec-Aging Inspection7/17/20207/17/20207/17/2020 8:06:38 AM CANC
final will pass when homeowner addresses MIS inspoection for other work
MEC19-04288 Mec-Aging Inspection7/17/20207/17/20207/17/2020 8:05:00 AM CANC
permit expired
MEC19-04288 DOC - Permit Expired7/17/20207/17/20207/17/2020 8:04:43 AMAPASS
permit expired- no calls no activity