Inspections for the day of: Tuesday, July 18, 2006.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE04-01224 ELE-Aging Inspection7/18/20067/18/20067/21/2006 11:50:21 AM NR
will call when done
ELE06-02602 Rough-In Permanent Service7/18/20067/18/20067/18/2006 4:21:05 PMPFAIL
ron -call 1st for access ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie--re-insp told people at house, left corr notice,nec 334.30 nm cable shall be stapled within 12" of box, nm cable shall not be stapled on edge, 300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing member, 314.20 in walls of combustible material box shall be flush with finished surface, 300.14 at least 6" of free conductor length shall emerge at each box 352.30 rnc shall be supported within 3' of box, BCC all make-up shall be done, all underground shall be inspected before cover
ELE06-02163 Final7/18/20067/18/20067/18/2006 3:52:35 PMPPASS
cal; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to final
ELE06-02596 Temporary Service7/18/20067/18/20067/18/2006 2:57:52 PMPPASS
zane ###-#### t/s o/h n ok
ELE06-02648 Permanent Service7/18/20067/18/20067/18/2006 1:50:23 PMPPASS
this address has been vacant for over a year for #3 --todd ###-#### p/s exst meter pak, rec ok
ELE06-02021 Permanent Service7/18/20067/18/20067/18/2006 1:28:37 PMPPASS
cory; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley p/s meter pak n ok
ELE06-02022 Permanent Service7/18/20067/18/20067/18/2006 1:27:12 PMPPASS
cory; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley p/s u/g n ok
ELE06-02625 Final7/18/20067/18/20067/18/2006 12:59:13 PMPPASS
steve; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to final, see p/s
ELE06-02625 Permanent Service7/18/20067/18/20067/18/2006 12:53:11 PMPPASS
steve; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley p/s o/h rec ok
ELE06-02181 Final7/17/20067/18/20067/18/2006 12:03:05 PMPCANC
Contact homeowner 2 hours before inspecting. ###-####. Work performed by Tom Wonacott.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz called contr and explained we need appointment and max 1/2 hour time spread
ELE06-01821 Final7/17/20067/18/20067/18/2006 11:59:05 AMACANC
tim; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called , address changed, permits not up to date, said to call when paperwork ok
ELE06-02420 Permanent Service7/17/20067/18/20067/18/2006 10:58:02 AMAPASS
back wall of big shop - outside --- ###-#### -jeff ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie corr made, p/s o/h n ok
ELE06-00464 Final7/17/20067/18/20067/18/2006 10:24:34 AMAPASS
Scheduled by a contractor via Hello! on 7/17/2006 at 4:15:10 PM. Contact: ###-####. ok to final
ELE06-02629 Conference7/17/20067/18/20067/18/2006 10:03:45 AMADONE
###-#### john talked about range wiring route and small appliance circuits, potential later room additions and garage, service change later, will leave lighting ckts as they are, dining room ok as is
ELE06-02607 Electrical Rough-In7/17/20067/18/20067/18/2006 9:14:00 AMAPASS
scott - call 1/2 hr prior to meet there ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ric ok
ELE06-02602 Rough-In Permanent Service7/17/20067/18/20067/18/2006 8:47:48 AMANH
Scheduled by a contractor via Hello! on 7/17/2006 at 7:25:42 PM. called, left message, tried door, left card
ELE06-01619 Final7/18/20067/18/20067/18/2006 8:37:18 AMAPASS
Scheduled by a contractor via Hello! on 7/18/2006 at 7:11:12 AM. Contact: ###-####. ok to final
ELE06-02632 Rough-In Permanent Service7/17/20067/18/20067/18/2006 8:24:04 AMAPASS
rich ###-#### ric ok , p/s u/g n ok
ELE06-02596 Temporary Service7/18/20067/18/20067/18/2006 12:00:00 AMPCANC
###-####- zane -re-insp--need to pay re-insp fee 1st
ELE06-02244 Final7/18/20067/18/20067/11/2006 12:00:00 AMPPASS
We installed a new rain tight main circuit breaker panel next to the existing meterbase,2)extended the existing circuits from the existing indoor panel thru the wall into the new outdoor panel,3)installed a new 20 amp 120 volt circuit with a receptacle for a microwave.(6060592p). J-man/Jason/###-####. Thanks !!!!; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell called elect to provide abrasion protection for gec, ok to final