Inspections for the day of: Wednesday, July 18, 2007.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-02528 Conference7/18/20077/18/20077/18/2007 3:58:46 PMPDONE
ed- ###-####-- talked about box fill and circuits for enclosed room over exst slab and when to call for inspection, free conductor length, new ckts and recpt spacing
ELE07-02524 Electrical Rough-In7/17/20077/18/20077/18/2007 3:39:45 PMPPASS
wayne - underground; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang u/g east side bldg only ok to cover
ELE07-02415 Electrical Rough-In7/18/20077/18/20077/18/2007 2:52:44 PMPPASS
clyde; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang called contr, ok to cover ceiling
ELE06-04004 Final7/17/20077/18/20077/18/2007 2:03:05 PMPFAIL
1:00 please...Duane ###-#### met owner, left correction notice, told owner he has to have contractor permit and final installation, nec 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member, 314.17(C) nm cable shall be strapped within 8" of box, 312.5 all conductors entering enclosure shall have abrasion protection, 250.53(B)&(G) electrodes shall be minimum 6' apart and driven in flush with or below grade, 406.8(B) outside recpts shall have enclosure that is weatherproof whether or not plug is inserted, 300.14 shall provide minimum 6" free length conductor at each box, 110.3(B) listed equipment shall be installed per instruction included with with listing (tighten clamps), BCC must update permit for service request
ELE07-02506 Electrical Rough-In7/18/20077/18/20077/18/2007 12:57:38 PMPPASS
We have made the changes in the bathroom that Pat requested by useing Colorado Jim straps Phone #: ###-#### Internet Inspection Request from: Scott Abbott corrections made, ric walls only ok plus hard lids in baths
ELE07-02534 Conference7/18/20077/18/20077/18/2007 12:21:18 PMPDONE
Kong ###-#### talked about wiring for covered patio, ri and final, recpts to be above panel in clg
ELE07-02349 Permanent Service7/17/20077/18/20077/18/2007 10:53:47 AMAPASS
calvin; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang corr made, p/s o/h n ok
ELE07-01059 ELE-Aging Inspection7/18/20077/18/20077/18/2007 10:19:17 AM DONE
see final
ELE07-01059 Final7/18/20077/18/20077/18/2007 10:19:02 AMAPASS
looked at sign, ok to final
ELE07-01197 ELE-Aging Inspection7/18/20077/18/20077/18/2007 9:50:30 AM DONE
see final
ELE07-01197 Final7/18/20077/18/20077/18/2007 9:50:18 AMAPASS
looked at signs, ok to final
ELE07-00860 Final7/18/20077/18/20077/18/2007 9:41:41 AMAPASS
looked at sign, ok to final
ELE07-02478 Electrical Rough-In7/17/20077/18/20077/18/2007 9:03:45 AMAPASS
FLOOR BOX RI Phone #: ###-#### Internet Inspection Request from: JENNY EMEL ok to pour 2 floor boxes only
ELE07-01362 Final7/17/20077/18/20077/18/2007 8:36:40 AMAPASS
Thanks Jack!! Phone #: ###-#### Internet Inspection Request from: Tracy corr made, ok to final, signed occ card