BLD06-02446
| FIRE-Final Inspection | 7/17/2007 | 7/18/2007 | 7/19/2007 9:17:23 AM | P | FAIL |
|
|
Provide lever hardware and remove the thumbturn deadbolt. Paint over the yellow parking stripes as per discussion for the fire dept turn around.
|
BLD06-01785
| FIRE-Final Inspection | 7/18/2007 | 7/18/2007 | 7/18/2007 3:49:18 PM | P | PASS |
|
|
Life safety pass
|
BLD06-01784
| FIRE-Final Inspection | 7/18/2007 | 7/18/2007 | 7/18/2007 3:48:10 PM | P | PASS |
|
|
Life safety passed.
|
FIR07-00458
| INSP-Sprinkler Rough-in | 7/17/2007 | 7/18/2007 | 7/18/2007 3:04:26 PM | A | PASS |
|
|
Sprinkler piping is ok to cover
|
BLD06-01651
| FIRE-Final Inspection | 7/17/2007 | 7/18/2007 | 7/18/2007 2:53:09 PM | A | PASS |
|
|
LIfe safety passed
|
FIR07-00044
| INSP-Final Inspection | 7/18/2007 | 7/18/2007 | 7/18/2007 2:16:24 PM | P | PASS |
|
|
Permit finaled
|
FIR07-00448
| INSP-Sprinkler Rough-in/Hydro | 7/17/2007 | 7/18/2007 | 7/18/2007 2:13:15 PM | A | FAIL |
|
|
The overhead piping located on the second floor has numerous changes. These changes match the installation drawings but these drawings have no city approval. Resubmittals will be required showing the changes. All of these changes are in the remote area on the second floor. Insulation will need to be installed in the unsprinklered concealed spaces prior to cover approval as well.
|
FIR06-00362
| INSP-Final Inspection | 7/18/2007 | 7/18/2007 | 7/18/2007 1:54:17 PM | P | FAIL |
|
|
The flow switch reported correctly to the remote annunciator and to central station but the tamper and low air reported as general trouble signals. They need to be supervisory. The trip test of the valve passed.
|
BLD07-01656
| FIRE-Final Inspection | 7/17/2007 | 7/18/2007 | 7/18/2007 1:00:53 PM | A | PASS |
|
|
Life safety passed. Duane with US Bank was on his way to repair the existing exit sign over the south exit doors to the elevator lobby.
|
FIR06-00657
| INSP-Final Inspection | 7/17/2007 | 7/18/2007 | 7/18/2007 12:03:19 PM | A | PASS |
|
|
Permit finaled. Inspection was for the last smoke detector and the last two a/v's.
|
BLD07-00547
| FIRE-Final Inspection | 7/17/2007 | 7/18/2007 | 7/18/2007 11:39:59 AM | A | PASS |
|
|
Life safety passed. Contractor is to repair one exit sign in the basement and verify with the structural inspector.
|
BLD07-00059
| FIRE-Final Inspection | 7/17/2007 | 7/18/2007 | 7/18/2007 10:44:18 AM | A | PASS |
|
|
Life safety passed.
|
BLD07-00058
| FIRE-Final Inspection | 7/17/2007 | 7/18/2007 | 7/18/2007 10:43:34 AM | A | PASS |
|
|
Life safety passed.
|
FIR07-00073
| INSP-Final Inspection | 7/17/2007 | 7/18/2007 | 7/18/2007 10:41:47 AM | A | PASS |
|
|
Per Troy ok for this permit to reference the TI of BLD06-01785 Permit finaled
|
FIR07-00196
| INSP-Final Inspection | 7/17/2007 | 7/18/2007 | 7/18/2007 10:41:18 AM | A | PASS |
|
|
Permit finaled
|
FIR06-00011
| INSP-Alarm Testing | 7/18/2007 | 7/18/2007 | 7/18/2007 12:00:00 AM | | DONE |
|
|
See Mike Timmermans notes and the city approved plans for items tested.
|