Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-00196 ELE-Aging Inspection7/18/20147/18/20147/21/2014 1:32:06 PM DONE
Still under construction
ELE10-00275 ELE-Aging Inspection7/18/20147/18/20147/21/2014 12:10:48 PM DONE
Drove by, no answer, posted correction notice
ELE14-01782 Final7/18/20147/18/20147/18/2014 2:02:24 PMPPASS
Kevin Phone #: ###-#### Final ok
ELE14-01795 Final7/17/20147/18/20147/18/2014 1:44:07 PMPPASS
Call Jimmy for questions. Phone #: ###-#### >> Inspection requested via web by John Edwards Final ok
ELE14-01782 Electrical Rough-In7/18/20147/18/20147/18/2014 1:35:06 PMPPASS
Kevin Phone #: ###-#### Bathroom ceiling grid rough in ok cover
MIS14-00162 ELE-Conference7/16/20147/18/20147/18/2014 12:12:47 PMAFAIL
(apt B) Substandard renters complaint concrete walls in bathroom crumbling, dry rot walls and ceiling, leaking around light fixture in ceiling, electrical problems with power going out alot, exposed wires in apartment, panel box is hot to touch, concerned with not enough power supply for 4 units in building.// Leeandra ###-#### BCC 4-05-18- lectrical permit required on AC unit added to Appt. A.
NEC 230.72(C)- Each tenant shall have access to accupants service.
NEC 230.79(C)- Each appt. single family dwelling and shall have minimum service rating of 100 amps for each unit.
Bldg originally designed for duplex. Building owner shall seek conditional use approval for use as 4-plex.
7 days to secure electrical contractor for over load issue.
7 days to secure mechanical permit for HVAC equiptment added.
ELE14-01950 Final7/17/20147/18/20147/18/2014 10:16:29 AMAPASS
Call Julie at ###-#### prior to arrival on site for bldg. access. Quality Electric contact is Carl Pettek ###-#### Phone #: ###-#### >> Inspection requested via web by Scott Campbell Final ok
ELE14-00794 Final7/18/20147/18/20147/18/2014 9:49:37 AMAFAIL
Please final. Phone #: ###-#### >> Inspection requested via web by nathan palmer BCC 4-05-32 Code violation not to be retained.
300.15- Each cable splice termination shall be located in a box. back patio north light fixture
ELE14-01946 Final7/17/20147/18/20147/18/2014 9:09:16 AMAPASS
Ran new 20 amp 120 volt dedicated circuit in EMT from the main panel located on the east side of the house to a new kitchen GFCI. Phone #: ###-#### >> Inspection requested via web by Dan Mitchell Final ok
ELE14-01946 Electrical Rough-In7/17/20147/18/20147/18/2014 9:08:47 AMAPASS
Ran new 20 amp 120 volt dedicated circuit in EMT from the main panel located on the east side of the house to a new kitchen GFCI. Phone #: ###-#### >> Inspection requested via web by Dan Mitchell Rough in ok
ELE14-01711 Final7/15/20147/18/20147/18/2014 8:57:48 AMAPASS
Erik Phone #: ###-#### Final ok