ELE10-01304
| ELE-Aging Inspection | 7/18/2014 | 7/18/2014 | 7/21/2014 2:37:27 PM | | DONE |
|
|
Home owner still needs to complete smoke/ carbon detector installation
|
ELE14-01925
| Final | 7/18/2014 | 7/18/2014 | 7/18/2014 2:01:45 PM | P | NR |
|
|
Thanks. ###-#### Phone #: ###-#### >> Inspection requested via web by Clay Morgan Not ready for final at this time.
|
ELE14-01925
| Permanent Service | 7/18/2014 | 7/18/2014 | 7/18/2014 2:01:00 PM | P | PASS |
|
|
Thanks. ###-#### Phone #: ###-#### >> Inspection requested via web by Clay Morgan p/s o/h n ok
|
ELE14-01934
| Electrical Rough-In | 7/18/2014 | 7/18/2014 | 7/18/2014 1:30:51 PM | P | PASS |
|
|
Uffer ground inspection. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery rough-in ok cover concrete encased electrode
|
ELE14-01421
| Final | 7/18/2014 | 7/18/2014 | 7/18/2014 1:12:58 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov final ok
|
ELE14-01948
| Final | 7/17/2014 | 7/18/2014 | 7/18/2014 12:04:52 PM | P | NR |
|
|
Contact: Jeremy Thornock. inspection for 2 ufer grounds Phone #: ###-#### >> Inspection requested via web by Deb Gooden Not ready for final at this time.
|
ELE14-01948
| Electrical Rough-In | 7/18/2014 | 7/18/2014 | 7/18/2014 12:02:56 PM | P | PART |
|
|
Contact: Jeremy Thornock. inspection for 2 ufer grounds Phone #: ###-#### >> Inspection requested via web by Deb Gooden Rough-in ok cover 1 of 2 concrete encased electrodes, northwest corner
|
ELE14-01548
| Electrical Rough-In | 7/18/2014 | 7/18/2014 | 7/18/2014 11:15:38 AM | P | PASS |
|
|
Need 2nd grid ceiling inspection. Phone #: ###-#### >> Inspection requested via web by Alan Lusk Rough-in ok cover ceiling grid in rms 102 thur 120
|
ELE14-01941
| Rough-In Permanent Service | 7/17/2014 | 7/18/2014 | 7/18/2014 10:46:55 AM | A | FAIL |
|
|
Call ahead for access, looking for 9:30ish inspection - Kevin Phone #: ###-#### Complete grounding connections NEC 230.6(5) shall not route unfused conductor along inside of walls of a building.
|
ELE14-01945
| Final | 7/17/2014 | 7/18/2014 | 7/18/2014 9:06:08 AM | A | FAIL |
|
|
Site is located near the southeast corner of the lot, next to N. Mitchell. Phone #: ###-#### >> Inspection requested via web by Dan Mitchell see rough-in
|
ELE14-01945
| Electrical Rough-In | 7/17/2014 | 7/18/2014 | 7/18/2014 9:05:17 AM | A | FAIL |
|
|
Site is located near the southeast corner of the lot, next to N. Mitchell. Phone #: ###-#### >> Inspection requested via web by Dan Mitchell NEC 406.8(B) All 15 and 20 ampere 120 and 250 volt receptacles shall be listed weather-resistant type.
|
ELE14-01925
| Permanent Service | 7/17/2014 | 7/18/2014 | 7/18/2014 8:46:08 AM | A | FAIL |
|
|
If you have any questions, please call Clay at ###-####. Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan NEC 250.56 Permanent service requires two grounding electrodes. NEC 312.5(C) Prohitbits the installation of several cables bunched together. NEC 210.8 requires GFCI protection for all 15 and 20 ampere 120 volt receptacles.
|