PLM15-00116 PLM-Aging Inspection7/18/20167/18/20167/18/2016 4:23:27 PM PART
wip
PLM16-02473 Sprinkler (Final)7/18/20167/18/20167/18/2016 4:22:45 PMPPASS
Leo Phone #: ###-####
PLM16-02557 Plumbing Rough-in7/15/20167/18/20167/18/2016 4:11:12 PMPFAIL
SITE SUPER: PAUL, ###-####. PLUMBING ROUGH IN Phone #: ###-#### Inspection requested via web by Chris Field
>need to roll vent above centerline on tub and wc in o/head.
>santee @ wc on main floor needs to be on vent not flange.
>nail plate top of wall behind upstairs tub and cold to washer box on main floor.
>3" trap to big for condensate, change to 2"
PLM16-01388 Plumbing Rough-in7/18/20167/18/20167/18/2016 3:29:19 PMPFAIL
Inspection requested via web by Erin Whiting
>backgraded at tub trap
>clamps to be 180 offset on w/s
>support all dwv every 4' attic and o/head
PLM16-01387 Plumbing Rough-in7/18/20167/18/20167/18/2016 3:28:09 PMPFAIL
Inspection requested via web by Erin Whiting
>grade wb drain 1/4" per ft
>90 ftg not square on pipe on vent from lav on o/head
>clamps to be 180 offset
>nail plate at stairs
>support all dwv every 4 foot o/head and attic
PLM16-01386 Plumbing Rough-in7/18/20167/18/20167/18/2016 3:25:05 PMPFAIL
Inspection requested via web by Erin Whiting
>backgraded 2" from lav
>ABS touching can light
>clamps to be 180 offset on w/s
>support all dwv every 4 foot o/head and attic
PLM16-01385 Plumbing Rough-in7/18/20167/18/20167/18/2016 3:23:45 PMPFAIL
Inspection requested via web by Erin Whiting
>roll vent at wc above centerline
>clamps need to be 180 offset on w/s
>support all dwv every 4 foot o/head and attic
PLM16-01384 Plumbing Rough-in7/18/20167/18/20167/18/2016 3:22:44 PMPFAIL
Inspection requested via web by Erin Whiting
>missing clamp on w/s
>grade 2" at firewall
>>support all dwv every 4 foot o/head and attic
PLM16-01383 Plumbing Rough-in7/18/20167/18/20167/18/2016 3:21:42 PMPFAIL
Inspection requested via web by Erin Whiting
>hose clamps need 180 offset on ws
>roll vents on wc's above centerline
>3" backgraded on o/head after wye
>support all dwv every 4 foot o/head and attic
PLM16-02433 Final7/18/20167/18/20167/18/2016 1:51:24 PMPPASS
Please call customer, Lori ###-####. Phone #: ###-#### Inspection requested via web by Kassy Goodwin
PLM16-02562 DOC - Permit Finaled7/18/20167/18/20167/18/2016 1:34:34 PMPPASS
PLM16-02562 Water and/or Sewer7/17/20167/18/20167/18/2016 1:34:27 PMPPASS
Phone #: ###-#### Inspection requested via web by Brett Simmons
PLM16-02561 DOC - Permit Finaled7/18/20167/18/20167/18/2016 1:29:19 PMPPASS
PLM16-02561 Water and/or Sewer7/17/20167/18/20167/18/2016 1:29:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Brett Simmons
PLM16-02560 DOC - Permit Finaled7/18/20167/18/20167/18/2016 1:23:45 PMPPASS
PLM16-02560 Water and/or Sewer7/17/20167/18/20167/18/2016 1:23:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Brett Simmons
PLM16-02541 Final7/14/20167/18/20167/14/2016 1:26:44 PMPCANC
please call prior to arrival ###-#### Phone #: ###-#### >> Inspection requested via web by Kassy Goodwin Inspection cancelled from web by: Kassy Goodwin