PLM15-00116
| PLM-Aging Inspection | 7/18/2016 | 7/18/2016 | 7/18/2016 4:23:27 PM | | PART |
|
|
wip
|
PLM16-02473
| Sprinkler (Final) | 7/18/2016 | 7/18/2016 | 7/18/2016 4:22:45 PM | P | PASS |
|
|
Leo Phone #: ###-####
|
PLM16-02557
| Plumbing Rough-in | 7/15/2016 | 7/18/2016 | 7/18/2016 4:11:12 PM | P | FAIL |
|
|
SITE SUPER: PAUL, ###-####. PLUMBING ROUGH IN Phone #: ###-#### Inspection requested via web by Chris Field >need to roll vent above centerline on tub and wc in o/head. >santee @ wc on main floor needs to be on vent not flange. >nail plate top of wall behind upstairs tub and cold to washer box on main floor. >3" trap to big for condensate, change to 2"
|
PLM16-01388
| Plumbing Rough-in | 7/18/2016 | 7/18/2016 | 7/18/2016 3:29:19 PM | P | FAIL |
|
|
Inspection requested via web by Erin Whiting >backgraded at tub trap >clamps to be 180 offset on w/s >support all dwv every 4' attic and o/head
|
PLM16-01387
| Plumbing Rough-in | 7/18/2016 | 7/18/2016 | 7/18/2016 3:28:09 PM | P | FAIL |
|
|
Inspection requested via web by Erin Whiting >grade wb drain 1/4" per ft >90 ftg not square on pipe on vent from lav on o/head >clamps to be 180 offset >nail plate at stairs >support all dwv every 4 foot o/head and attic
|
PLM16-01386
| Plumbing Rough-in | 7/18/2016 | 7/18/2016 | 7/18/2016 3:25:05 PM | P | FAIL |
|
|
Inspection requested via web by Erin Whiting >backgraded 2" from lav >ABS touching can light >clamps to be 180 offset on w/s >support all dwv every 4 foot o/head and attic
|
PLM16-01385
| Plumbing Rough-in | 7/18/2016 | 7/18/2016 | 7/18/2016 3:23:45 PM | P | FAIL |
|
|
Inspection requested via web by Erin Whiting >roll vent at wc above centerline >clamps need to be 180 offset on w/s >support all dwv every 4 foot o/head and attic
|
PLM16-01384
| Plumbing Rough-in | 7/18/2016 | 7/18/2016 | 7/18/2016 3:22:44 PM | P | FAIL |
|
|
Inspection requested via web by Erin Whiting >missing clamp on w/s >grade 2" at firewall >>support all dwv every 4 foot o/head and attic
|
PLM16-01383
| Plumbing Rough-in | 7/18/2016 | 7/18/2016 | 7/18/2016 3:21:42 PM | P | FAIL |
|
|
Inspection requested via web by Erin Whiting >hose clamps need 180 offset on ws >roll vents on wc's above centerline >3" backgraded on o/head after wye >support all dwv every 4 foot o/head and attic
|
PLM16-02433
| Final | 7/18/2016 | 7/18/2016 | 7/18/2016 1:51:24 PM | P | PASS |
|
|
Please call customer, Lori ###-####. Phone #: ###-#### Inspection requested via web by Kassy Goodwin
|
PLM16-02562
| DOC - Permit Finaled | 7/18/2016 | 7/18/2016 | 7/18/2016 1:34:34 PM | P | PASS |
|
|
|
PLM16-02562
| Water and/or Sewer | 7/17/2016 | 7/18/2016 | 7/18/2016 1:34:27 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM16-02561
| DOC - Permit Finaled | 7/18/2016 | 7/18/2016 | 7/18/2016 1:29:19 PM | P | PASS |
|
|
|
PLM16-02561
| Water and/or Sewer | 7/17/2016 | 7/18/2016 | 7/18/2016 1:29:10 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM16-02560
| DOC - Permit Finaled | 7/18/2016 | 7/18/2016 | 7/18/2016 1:23:45 PM | P | PASS |
|
|
|
PLM16-02560
| Water and/or Sewer | 7/17/2016 | 7/18/2016 | 7/18/2016 1:23:35 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM16-02541
| Final | 7/14/2016 | 7/18/2016 | 7/14/2016 1:26:44 PM | P | CANC |
|
|
please call prior to arrival ###-#### Phone #: ###-#### >> Inspection requested via web by Kassy Goodwin Inspection cancelled from web by: Kassy Goodwin
|