PLM16-04510
| Final | 7/17/2017 | 7/18/2017 | 7/18/2017 5:19:58 PM | A | FAIL |
|
|
Carl Phone #: ###-####. 1. Senser wire connection on the roof must be waterproof. 2. Water lines on the roof must be supported per code. 3. Pipe insulation must be rated at R-5 or grater. 4. T&P drains must run full size to 24" to 6" above grade. If two 3/4" are combined they must increase to 1-1/4". 5. T&P drains must be graded at 1/4"/ft. 6. Add a shut-off valve at the water heater next to the storage tank on the inlet side. 7. The cold water feed to the hot water heaters are undersized. Either provide unit fixture count and sizing or increase to 1" back to the water conditioner. 8. The solar panal piping must have a manual shut-off and draindown system. 9. Provide a seconday heat source or automatic draindown system to protect the potable water system at exposed locations. 10. The system must be complete and functioning. Install hot tub. Further corrections may apply after system design review. Please provide a system design to show how all potable water will be protected; including control function and winterization. This must be provided in writing.
|
PLM17-02635
| Final | 7/18/2017 | 7/18/2017 | 7/18/2017 4:11:16 PM | P | PASS |
|
|
Micheal Phone #: ###-####
|
PLM16-03533
| PLM-Aging Inspection | 7/18/2017 | 7/18/2017 | 7/18/2017 3:44:50 PM | | PASS |
|
|
|
PLM16-03533
| Final | 7/18/2017 | 7/18/2017 | 7/18/2017 3:44:35 PM | P | PASS |
|
|
|
PLM17-02608
| Water Heater Final | 7/18/2017 | 7/18/2017 | 7/18/2017 3:43:43 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Robert Madrigal
|
PLM17-02609
| Water and/or Sewer | 7/17/2017 | 7/18/2017 | 7/18/2017 2:57:01 PM | P | NR |
|
|
|
PLM17-02407
| Groundwork | 7/17/2017 | 7/18/2017 | 7/18/2017 2:56:33 PM | P | PART |
|
|
RUSSELL IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER. Kitchen plumbing in southeast corner ok to cover. Grease trap vent to be coredrilled and inspected on rough-in
|
PLM17-02501
| Other | 7/18/2017 | 7/18/2017 | 7/18/2017 2:17:51 PM | P | PART |
|
|
Start 24 hour test on two interceptor tanks
|
PLM17-02501
| Groundwork | 7/17/2017 | 7/18/2017 | 7/18/2017 2:15:13 PM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Nicholas Paige Start 24 hour test on the two interceptors.
|
PLM17-02510
| Plumbing Rough-in | 7/18/2017 | 7/18/2017 | 7/18/2017 1:49:03 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Nels Moore
|
PLM17-02654
| Water Heater Final | 7/17/2017 | 7/18/2017 | 7/18/2017 1:15:57 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Chris Field
|
PLM16-04608
| PLM-Aging Inspection | 7/18/2017 | 7/18/2017 | 7/18/2017 12:50:55 PM | | PEND |
|
|
Expire in October if no response.
|
PLM17-02639
| Water and/or Sewer | 7/17/2017 | 7/18/2017 | 7/18/2017 12:48:18 PM | A | CANC |
|
|
Troy Phone #: ###-####. Public works jurisdiciton
|
PLM17-01434
| Groundwork | 7/17/2017 | 7/18/2017 | 7/18/2017 10:24:02 AM | A | PART |
|
|
if questions call Noe @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann. West end plumbing ok to cover
|
PLM17-00713
| Final | 7/17/2017 | 7/18/2017 | 7/17/2017 4:39:39 PM | A | PASS |
|
|
2224 ENTER Phone #: ###-#### Inspection requested via web by Ann Marie Reyes. The master bathtub was eleminated and perm capped
|
PLM17-02609
| Water and/or Sewer | 7/17/2017 | 7/18/2017 | 7/17/2017 4:26:13 PM | A | CANC |
|
|
Dan - in order to keep the clients yard open, we''ll have to dig, install ; backfill in 2 stages. We will start about 10 am Tues, 7-18-17, once equipment mobilized to project. Please call Brandon Dibble at ###-#### Phone #: ###-#### Inspection requested via web by Betty Dibble
|