ELE05-02161
| Final | 7/14/2005 | 7/19/2005 | 7/19/2005 4:25:59 PM | P | FAIL |
|
|
Ready for Final inspection. Electrician should be on site. Thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH 800.24 communication circuits shall be installed in such a manner that the cable will not be damaged, 406.4(D) receptacle face plates shall project a minimum .015" from metal faceplates, met with contr, left corr notice
|
ELE05-02580
| Electrical Rough-In | 7/19/2005 | 7/19/2005 | 7/19/2005 4:22:55 PM | P | PASS |
|
|
###-#### - clyde ric ok, p/s u/g n ok
|
ELE05-02589
| Electrical Rough-In | 7/19/2005 | 7/19/2005 | 7/19/2005 4:22:19 PM | P | PASS |
|
|
Soffit cover inspection; Phone #: ###-#### Internet Inspection Request from: Tyler Bowen soffits only ok to cover
|
ELE05-02584
| Electrical Rough-In | 7/19/2005 | 7/19/2005 | 7/19/2005 3:14:43 PM | P | PASS |
|
|
###-#### - ron ric ok, p/s u/g n ok
|
ELE05-01399
| Permanent Service | 7/18/2005 | 7/19/2005 | 7/19/2005 2:29:32 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 7/18/2005 at 2:12:40 PM. Contact: ###-####. p/s u/g n ok
|
ELE05-01774
| Final | 7/19/2005 | 7/19/2005 | 7/19/2005 12:32:06 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 7/19/2005 at 9:47:38 AM. Contact: ###-####. called contr, left corr notice, 210.52(H) at least 1 recpt shall be in hall if over 10' (upstairs)
|
ELE05-01923
| Final | 7/18/2005 | 7/19/2005 | 7/19/2005 10:07:48 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 7/18/2005 at 9:48:12 AM. Contact: ###-####. ok to final
|
ELE05-01633
| Final | 7/18/2005 | 7/19/2005 | 7/19/2005 9:50:01 AM | A | PASS |
|
|
Call Dan for garage code.; Phone #: ###-#### Internet Inspection Request from: Dan Rohl called elect about tub gfci. ok to final
|
ELE05-01098
| Final | 7/18/2005 | 7/19/2005 | 7/19/2005 9:47:04 AM | A | PASS |
|
|
call for access information///earl ; Phone #: ###-#### Internet Inspection Request from: Barbara Moore told elect, left survey 422.16(B) waste disposal cord shall be suitable for use. ok to final
|
ELE05-02557
| Rough-In Permanent Service | 7/18/2005 | 7/19/2005 | 7/19/2005 8:34:36 AM | A | PASS |
|
|
dino ###-#### called contr to re-install staples for 2 recpts. ric ok, p/s u/g n ok
|
ELE05-02482
| Electrical Rough-In | 7/18/2005 | 7/19/2005 | 7/19/2005 8:26:03 AM | A | PASS |
|
|
If possible can you please be on site by 10 am; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH u/g only ok to cover
|