Inspections for the day of: Friday, July 19, 2013.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01894 Electrical Rough-In7/18/20137/19/20137/22/2013 8:09:18 AMPFAIL
call 30-45 min before//Mucho Phone #: ###-#### Hot tub requires service receptacle, rain gutter bonding needs to terminate at hot tub equipment
ELE13-01616 Final7/19/20137/19/20137/19/2013 4:26:07 PMPCANC
late afternoon please Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Requested cancel by electrical contractor
ELE13-01899 Electrical Rough-In7/18/20137/19/20137/19/2013 4:22:47 PMPPASS
Need to let you in can you call the job boss and let him know what time you think you will be there, if you can let him know 30min or more notice that would be great thank you. Goddy @ ###-#### or call me Phone #: ###-#### >> Inspection requested via web by Neal Rumsey rough-in ok cover listed cable floor heat
ELE13-01906 Permanent Service7/19/20137/19/20137/19/2013 4:21:20 PMPPASS
house code is 6569 Phone #: ###-#### >> Inspection requested via web by Dan Rohl p/s o/h rec ok
GCE13-00047 GCE-Final7/19/20137/19/20137/19/2013 4:19:49 PMPPASS
job complete, final ok
GCE13-00047 GCE-Rough-In7/19/20137/19/20137/19/2013 4:18:44 PMPDONE
###-#### ready for final
ELE13-00086 Electrical Rough-In7/19/20137/19/20137/19/2013 1:52:01 PMPPASS
Dave. Basement & 1st floor ceiling cover. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy rough in ok cover ceiling grid
ELE13-01891 Final7/18/20137/19/20137/19/2013 12:41:00 PMAPASS
robert Phone #: ###-#### final ok
ELE13-01042 Final7/19/20137/19/20137/19/2013 12:21:03 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn final ok
ELE13-01843 Final7/19/20137/19/20137/19/2013 12:11:55 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn final ok
ELE13-01892 Final7/18/20137/19/20137/19/2013 11:40:50 AMAFAIL
robert Phone #: ###-#### No power at service receptacle
ELE13-01830 Final7/18/20137/19/20137/19/2013 11:10:23 AMAPASS
ahmad Phone #: ###-#### final ok
ELE13-01887 Final7/19/20137/19/20137/19/2013 10:47:28 AMPPASS
job complete, final ok
ELE13-01887 Electrical Rough-In7/18/20137/19/20137/19/2013 10:46:53 AMAPASS
mini split. Job is complete. Phone #: ###-#### >> Inspection requested via web by Stuart Welton rough-in ok
ELE13-01526 Electrical Rough-In7/18/20137/19/20137/19/2013 10:35:45 AMAPASS
Casey Phone #: ###-#### rough-in ok cover basement
ELE13-01885 Electrical Rough-In7/18/20137/19/20137/19/2013 10:10:49 AMAPASS
mike Phone #: ###-#### rough-in ok cover walls
ELE13-01889 Final7/19/20137/19/20137/19/2013 9:45:04 AMPPASS
job complete final ok
ELE13-01889 Electrical Rough-In7/18/20137/19/20137/19/2013 9:44:24 AMAPASS
mini split system. Behind carport in backyard. Job is complete. Phone #: ###-#### >> Inspection requested via web by Stuart Welton rough-in ok
ELE13-01897 Electrical Rough-In7/18/20137/19/20137/19/2013 9:16:56 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Clint Tate NEC 330.30 MC cable shall be secured within 12 in. NEC 362.26 shall not be more than 360 degrees between pull points NEC 362.30 ENT Securely fastened. KO plugs where needed