ELE17-01776
| Electrical Rough-In | 7/19/2017 | 7/19/2017 | 7/19/2017 2:13:10 PM | P | PASS |
|
|
Ceiling Phone #: ###-#### Inspection requested via web by Jim Williams Corridor not ready. TI grid rough in ok cover
|
MIS17-00225
| ELE-Conference | 7/18/2017 | 7/19/2017 | 7/19/2017 12:53:37 PM | A | FAIL |
|
|
as per Eric Strole work w/o permits Unable to gain access to interior. Observed building materials through door window. BCC 4-05-18. Electrical permit required prior to start of work. Posted notice
|
ELE17-01574
| Final | 7/18/2017 | 7/19/2017 | 7/19/2017 10:59:20 AM | A | PASS |
|
|
Garage code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE17-01776
| Electrical Rough-In | 7/19/2017 | 7/19/2017 | 7/19/2017 10:16:05 AM | A | NR |
|
|
Ceiling Phone #: ###-#### Inspection requested via web by Jim Williams 300.11- All luminaires shall be supported independant of grid. Grid wires installed but not installed on luminaires yet. Will recall
|
ELE17-02174
| Final | 7/18/2017 | 7/19/2017 | 7/19/2017 10:14:47 AM | A | NR |
|
|
garage code 0324 Phone #: ###-#### Inspection requested via web by Darryn Coburn rough in done on 7-17-17. requested wrong job.
|
ELE17-01282
| Final | 7/18/2017 | 7/19/2017 | 7/19/2017 10:11:09 AM | A | FAIL |
|
|
garage code 1524 Phone #: ###-#### Inspection requested via web by Darryn Coburn 422.11(A)- Branch circuit and overcurrent device shall be sized as per manufacturers instructions. 15 amp installed, 20 amp and 12ga. min.noted.
|