ELE06-03281
| Final | 7/2/2007 | 7/2/2007 | 7/2/2007 2:52:12 PM | P | CANC |
|
|
Please inspect 1st and 2nd floor of A-wing ceiling cover. Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Friend called already done on added r/i 06-29-07
|
ELE07-02325
| Rough-In Permanent Service | 7/2/2007 | 7/2/2007 | 7/2/2007 2:51:02 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 7/2/2007 at 10:59:55 AM. Contact: ###-####. r/i p/s u/g new ok
|
ELE07-02299
| Electrical Rough-In | 7/2/2007 | 7/2/2007 | 7/2/2007 2:19:52 PM | P | PART |
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang conference on p/s no SER allowed in conduit, needs 3/0 copper or 250KC mil for 400 amp feeder, r/i for back office and restrm area ok walls and hard ceilings
|
ELE07-02316
| Electrical Rough-In | 7/2/2007 | 7/2/2007 | 7/2/2007 1:33:52 PM | P | PART |
|
|
ufer inspection. had to make one mudder forgot thanks joe. Phone #: ###-#### Internet Inspection Request from: joe wheeler electrode ok for concrete cover
|
ELE07-02108
| Final | 7/2/2007 | 7/2/2007 | 7/2/2007 1:06:38 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Monty Adkinson ok
|
ELE07-02313
| Electrical Rough-In | 7/2/2007 | 7/2/2007 | 7/2/2007 12:43:21 PM | P | FAIL |
|
|
electrician is Tony Norton, service relocated and shop rough in Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer corr. do not cover posted called left message110.12(A) seal KOs, BCC needs concrete encased electrode, no violations retained 110.3(B) only manufactures listed breakers, subpanel, 314.43 no nails allowed in plastic boxes, 300.4(A)(1) nail plates above subpanel, 230.24(A) except. #3 needs 18" from roof to drip loop, 250.24(A)(5) isolate grds and neutrsals subpanel, 250.24(A)(1) or 104(A)(1) grd or bond water system?
|
ELE06-00711
| Electrical Rough-In | 6/29/2007 | 7/2/2007 | 7/2/2007 11:07:54 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 6/29/2007 at 10:05:24 AM. Contact: ###-####. 2nd floor completed ceilings ok, 4th floor roof garden and completed grid ceilings anop
|
ELE07-02245
| Electrical Rough-In | 6/29/2007 | 7/2/2007 | 7/2/2007 9:58:16 AM | A | PART |
|
|
Building branch underground Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton u/g ok
|
ELE07-02005
| Permanent Service | 7/1/2007 | 7/2/2007 | 7/2/2007 9:38:02 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 7/1/2007 at 10:15:18 PM. Contact: ###-####. p/s u/g new ok
|
ELE07-02337
| Permanent Service | 6/29/2007 | 7/2/2007 | 7/2/2007 9:18:57 AM | A | PASS |
|
|
EDDIE ###-#### p/s u/g rec. ok
|
ELE07-02337
| Final | 7/2/2007 | 7/2/2007 | 7/2/2007 9:18:17 AM | A | PASS |
|
|
EDDIE ###-#### ok
|
ELE07-01840
| Final | 6/29/2007 | 7/2/2007 | 7/2/2007 8:53:11 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: JENNY EMEL ok card signed
|
ELE07-01588
| Final | 6/29/2007 | 7/2/2007 | 7/2/2007 8:26:16 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange ok
|
ELE07-01587
| Final | 6/29/2007 | 7/2/2007 | 7/2/2007 8:25:58 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange ok
|
ELE07-02245
| Electrical Rough-In | 6/28/2007 | 7/2/2007 | 6/29/2007 3:21:03 PM | P | CANC |
|
|
Underground
Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton Inspection cancelled from web by: Kerri Hamilton
|
ELE07-02245
| Electrical Rough-In | 6/28/2007 | 7/2/2007 | 6/28/2007 1:56:57 PM | A | CANC |
|
|
Underground Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton Inspection cancelled from web by: Kerri Hamilton
|