Inspections for the day of: Thursday, July 2, 2009.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-02969 ELE-Aging Inspection7/2/20097/2/20097/6/2009 10:17:33 AM DONE
no activity, suc
ESC07-00842 General Inspection7/2/20097/2/20097/2/2009 3:42:58 PMPPASS
did not see yellow sign, rest appears to be ok
ESC09-00021 General Inspection7/2/20097/2/20097/2/2009 3:41:15 PMPPART
did not see yellow sign, wating for sewer line to be installed, looked like in progress
ELE09-00923 Final7/2/20097/2/20097/2/2009 3:38:15 PMPPASS
darren Phone #: ###-#### ok to final
ELE09-00694 Conference7/2/20097/2/20097/2/2009 3:23:04 PMADONE
met with contractor and other electrcal inspectors to review switchgear that did not have good instructions for gounding transformer, no esc this project
ESC09-00179 General Inspection7/2/20097/2/20097/2/2009 2:45:55 PMPPASS
looked ok
ESC08-00836 General Inspection7/2/20097/2/20097/2/2009 2:11:11 PMPPASS
looked ok, prepping for sod, told rp to keep sign posted
ELE09-01165 Final7/2/20097/2/20097/2/2009 1:35:40 PMPPASS
Late afternoon please. Randy ###-#### Phone #: ###-#### Internet Inspection Request from: Randy Fletcher ok to final, no esc this project
ELE09-01165 Permanent Service7/2/20097/2/20097/2/2009 1:34:58 PMPPASS
Late afternoon please. Randy ###-#### Phone #: ###-#### Internet Inspection Request from: Randy Fletcher p/s o/h rec ok, no esc this project
ELE09-01164 Final7/2/20097/2/20097/2/2009 1:34:03 PMPPASS
Mike Phone #: ###-#### ok to final, no esc this project
ELE09-01164 Permanent Service7/2/20097/2/20097/2/2009 1:10:29 PMPPASS
Mike Phone #: ###-#### p/s o/h rec ok, no esc this project
ELE09-01152 Electrical Rough-In7/2/20097/2/20097/2/2009 12:40:24 PMPPASS
Eupher Inspection Phone #: ###-#### Internet Inspection Request from: Ron Zimmerman ok to pour gec
ELE09-01161 Electrical Rough-In7/1/20097/2/20097/2/2009 10:31:21 AMAPASS
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten called, ric ok, no esc this project, called structural to check on bld
ELE09-01135 Permanent Service7/1/20097/2/20097/2/2009 10:03:48 AMPCANC
Phone #: ###-#### Internet Inspection Request from: Robert Murray Inspection cancelled from web by: Robert Murray
ELE09-01143 Temporary Service7/1/20097/2/20097/2/2009 9:52:32 AMAPASS
dave Phone #: ###-#### called contractor, t/s o/h n ok, no esc this project
ELE09-00852 Permanent Service7/1/20097/2/20097/2/2009 9:04:37 AMAPASS
Brian Phone #: ###-#### called, left message, left survey, NEC 250.56 a single electrode that does not have 25 ohms or less resistance to ground shall be augmented by 1 additional electrode, p/s u/g n ok
ELE09-01147 Electrical Rough-In7/1/20097/2/20097/2/2009 8:33:33 AMAPASS
Jim is the onsite his no. is ###-####. Phone #: ###-#### Internet Inspection Request from: Shawna Gates ric ok top and bottom, no esc this project