Inspections for the day of: Friday, July 2, 2010.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-01896 ELE-Aging Inspection7/2/20107/2/20107/9/2010 6:29:23 AM DONE
see doc expire
ELE09-01611 ELE-Aging Inspection7/2/20107/2/20107/8/2010 6:35:00 AM DONE
see doc expire
ELE10-01478 Rough-In Permanent Service7/2/20107/2/20107/2/2010 3:34:18 PMPCANC
richard Phone #: ###-#### see ri and p/s
ELE10-01478 Electrical Rough-In7/2/20107/2/20107/2/2010 3:22:40 PMPFAIL
richard Phone #: ###-#### called gave correction notice, NEC 300.5 u/g for pvc shall be 18" deep, not 12"
ELE10-01478 Electrical Rough-In7/2/20107/2/20107/2/2010 3:22:25 PMPFAIL
richard Phone #: ###-#### called gave correction notice, NEC 300.5 u/g for pvc shall be 18" deep, not 12"
ELE10-01478 Permanent Service7/2/20107/2/20107/2/2010 3:20:50 PMPPASS
richard Phone #: ###-#### p/s o/h n ok
ELE10-01275 Electrical Rough-In7/2/20107/2/20107/2/2010 3:19:25 PMPPASS
Inspection requested from web by: Shaun Kirkman Phone #: ###-#### ric ok
ELE10-01423 Permanent Service7/1/20107/2/20107/2/2010 2:27:02 PMPPASS
Inspection requested from web by: Barbara Szurgot Phone #: ###-#### called, p/s o/h rec ok
ELE10-01480 Rough-In Permanent Service7/2/20107/2/20107/2/2010 1:29:19 PMPPASS
Please inspect the Service that was damaged in the wind storm. Please Final the Permit when complete. Home Owner has not had power since Wednesday. Home Owner is Kevin at ###-#### or Kathleen at ###-####. Our Wireman is Mark at ###-####. Thank you. Inspection requested from web by: Clint Tate Phone #: ###-#### p/s o/h rec ok will call for final later
ELE09-01409 Final7/2/20107/2/20107/2/2010 1:07:32 PMPPART
This is for a final inspection in the maintenance shed and 1st floor south. Please contact Jeff Moe if there are any questions. ###-#### Inspection requested from web by: Spencer Mclean Phone #: ###-#### shed and south part 1st floor only ok
ELE10-01176 Final7/1/20107/2/20107/2/2010 12:25:23 PMPFAIL
garage code is 5555, thanks Inspection requested from web by: Stephen Kren Phone #: ###-#### called, left correction notice, NEC 422.11(A) a/c shall be protected by max 25a overcurrent device, BCC all work shall be done: a/c connected, rear ourside receptacle installed, front light installed, box shall be flush with finished surface per NEC 314.20, NOTE: corrections shall be made within 5 working days or further action will be taken such as removal of power, fee due
ELE10-01282 Electrical Rough-In7/1/20107/2/20107/2/2010 11:33:39 AMPCANC
Need ok to cover inside kitchen walls and trench for the hot tub conduit. Inspection requested from web by: John Edwards Phone #: ###-#### contractor asked to cancel for 7/2/10
ELE10-01173 Final7/1/20107/2/20107/2/2010 10:43:03 AMAPASS
Bathroom remodel and panel installation Inspection requested from web by: Steve Craig Phone #: ###-#### ok to final
ELE10-01431 Final7/2/20107/2/20107/2/2010 10:33:18 AMPPASS
Inspection requested from web by: Celinda Winters Phone #: ###-#### ok to final, signed card
ELE10-01075 Final7/2/20107/2/20107/2/2010 9:56:26 AMAPASS
contact 30 minutes ahead for access. Inspection requested from web by: david bradshaw Phone #: ###-#### ok to final, no card to sign
ELE10-01475 Electrical Rough-In7/2/20107/2/20107/2/2010 9:45:08 AMAPASS
This is a rough in inspection for the washer and dryer circuits. They are moving them into an adjacent closet and want power in there for them. Call with any questions. Thanks, Eric Inspection requested from web by: Eric Schroeder Phone #: ###-#### ri ok
ELE10-00978 Permanent Service7/1/20107/2/20107/2/2010 9:11:53 AMAPASS
bruce Phone #: ###-#### p/s u/g n ok
ELE10-01330 Final7/1/20107/2/20107/2/2010 8:40:50 AMAPASS
andy Phone #: ###-#### called, ok to final, signed card
ELE10-01463 Electrical Rough-In6/30/20107/2/20107/2/2010 8:15:23 AMAPASS
Brett Phone #: ###-#### walls only ok to cover
ELE09-01982 ELE-Aging Inspection7/2/20107/2/20107/2/2010 6:25:19 AM DONE
no activity
ELE09-01981 ELE-Aging Inspection7/2/20107/2/20107/2/2010 6:24:50 AM DONE
no activity
ELE08-02344 ELE-Aging Inspection7/2/20107/2/20107/2/2010 6:20:04 AM DONE
suc
ELE08-02271 ELE-Aging Inspection7/2/20107/2/20107/2/2010 6:18:24 AM DONE
see doc expire
ELE08-02271 DOC - Permit Expired7/2/20107/2/20107/2/2010 6:18:10 AMAPASS
no activity