Inspections for the day of: Monday, July 2, 2018.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-01084 ELE-Aging Inspection7/2/20187/2/20187/3/2018 7:45:06 AM DONE
ongoing project as per notes
ELE18-01886 Final7/2/20187/2/20187/2/2018 2:58:08 PMPPASS
Phone #: ###-#### Inspection requested via web by David Feller final ok
ELE18-02274 Electrical Rough-In7/2/20187/2/20187/2/2018 2:36:40 PMPPASS
Pole base Phone #: ###-#### Inspection requested via web by Jason Wicks Bases poured prior to inspection. Same as previous 6 rough in ok
ELE17-04345 Final6/29/20187/2/20187/2/2018 2:07:37 PMPPASS
Jeff Phone #: ###-#### Corrections made final ok
ELE18-01541 Final7/2/20187/2/20187/2/2018 2:02:13 PMPPASS
Garage code is 1001e Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
ELE18-02465 Temporary Service7/2/20187/2/20187/2/2018 1:51:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE18-02469 Temporary Service7/2/20187/2/20187/2/2018 1:11:20 PMPPASS
Phone #: ###-#### Inspection requested via web by Don Conley t/s u/g n ok
ELE18-02463 Rough-In Permanent Service7/1/20187/2/20187/2/2018 1:10:26 PMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson Check for floor receps near both back patio doors and SW entry walls at final rough in ok p/s u/g n ok
ELE18-01439 Electrical Rough-In7/2/20187/2/20187/2/2018 12:33:33 PMPPASS
Rough-in inspection for rear of house addition and remodel. Thank you! If possible, early afternoon please. Thanks! Phone #: ###-#### Inspection requested via web by Adam Staigle Rough in ok
ELE17-04169 Electrical Rough-In7/2/20187/2/20187/2/2018 12:30:23 PMPPASS
Roger-you have 2 at this address different permit numbers Phone #: ###-#### Rec room only ok to cover
ELE17-03559 Final7/1/20187/2/20187/2/2018 11:32:04 AMAPASS
Please call prior. I can be at the home in ten minutes from work. Thanks, Jim Phone #: ###-#### Inspection requested via web by James Hinen Final ok
ELE18-00924 Final6/29/20187/2/20187/2/2018 9:54:28 AMAFAIL
call Art ahead of time if you can ###-#### Phone #: ###-#### Inspection requested via web by A.M.E. Office 210.8 Receps within 6ft of a sink shall be GFCI protected. Mini Split shall be wired.
ELE18-02320 Electrical Rough-In6/29/20187/2/20187/2/2018 9:26:20 AMAPASS
Call when you get there // Ben Phone #: ###-#### Discussed moving tranformer to platform above mech room. Panel wall only ok to cover
ELE18-01540 Electrical Rough-In6/29/20187/2/20187/2/2018 9:13:50 AMANR
we would like to request an early morning inspecton, need a ceiling cover. Tobias is the site contact Phone #: ###-#### Inspection requested via web by Stacie Tasker Missing exit signs
ELE17-04131 Electrical Rough-In6/29/20187/2/20187/2/2018 9:13:27 AMAFAIL
we would like to request an early morning inspection for a ceiling cover. Tobias is the site contact.
Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker 336.12 2. TC cable shall not be ran outside of a raceway or cable tray except from tray to equipment.
ELE18-01532 Final7/2/20187/2/20187/2/2018 8:49:32 AMACANC
Phone #: ###-#### >> Inspection requested via web by BRS Permitting Inspection cancelled from web by: BRS Permitting
ELE18-01251 Final6/29/20187/2/20187/2/2018 7:29:13 AMAPASS
Blanket permit for building 51 Phone #: ###-#### Inspection requested via web by Ken Heller blanket permit only final ok