Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-03848 PLM-Aging Inspection7/2/20187/2/20187/2/2018 3:54:55 PM NR
contractor to schedule
PLM17-03845 PLM-Aging Inspection7/2/20187/2/20187/2/2018 3:54:19 PM DEFR
Contractor to schedule
PLM18-02780 Plumbing Rough-in7/2/20187/2/20187/2/2018 3:50:30 PMPPASS
Phone #: ###-#### Inspection requested via web by Andrew Wilde
PLM18-02779 Plumbing Rough-in7/2/20187/2/20187/2/2018 3:50:18 PMPPASS
Phone #: ###-#### Inspection requested via web by Andrew Wilde
PLM18-02778 Plumbing Rough-in7/2/20187/2/20187/2/2018 3:50:06 PMPFAIL
Phone #: ###-#### Inspection requested via web by Andrew Wilde. DWV test failed
PLM18-00613 Final7/2/20187/2/20187/2/2018 3:08:58 PMPPART
Anthony Phone #: ###-####
PLM17-04672 Final7/2/20187/2/20187/2/2018 3:08:16 PMPPART
Anthony Phone #: ###-####
PLM18-02553 Water Heater Final6/29/20187/2/20187/2/2018 1:51:02 PMPPASS
Please call ###-#### when on way Phone #: ###-#### Inspection requested via web by JEREMY LINK
PLM18-02715 Water Heater Final6/27/20187/2/20187/2/2018 1:22:00 PMAFAIL
Please call Dennis at ###-#### when on way Phone #: ###-#### Inspection requested via web by JEREMY LINK.
The t&p must be turned down. It cannot point straight out.
PLM18-02679 Final6/29/20187/2/20187/2/2018 11:20:37 AMAFAIL
Backflow was tested and passed by Pacific Backflow. Phone #: ###-#### Inspection requested via web by McKenna Haycock.
1. The double check valve is not an approved backflow assembly for irrigation per ISPC. Any backflow assembly that is changed out must be brought up to code.
2. PVC male fitting must be a minimum of schedule 80. ISPC 605.12.3
PLM18-01162 Final6/29/20187/2/20187/2/2018 10:54:54 AMAFAIL
Phone #: ###-#### Inspection requested via web by Ryan Baker.
1. The t&p and pan drains are trapped in the crawl.
2. Locate the irrigation backflow assembly. It must be to code and certified by code.
PLM18-02769 Water and/or Sewer6/29/20187/2/20187/2/2018 10:16:57 AMAFAIL
Phone #: ###-#### Inspection requested via web by Michael Klaas..
1. The tracer wire must extend above grade.
2. The double check valve must be certified.
3. Provide access to the crawl.
PLM18-00346 Final7/2/20187/2/20187/2/2018 10:00:31 AMAFAIL
Phone #: ###-#### Inspection requested via web by David Scaggs.
The water is off to all the units.
Label all the unit shut-off valves with unit numbers.
All the irrigation rp to your permit or the irrigation contractor must pull a permit. Have certifed for final.
PLM17-02944 PLM-Aging Inspection7/2/20187/2/20187/2/2018 9:22:36 AM PASS
PLM17-02944 DOC - Permit Expired7/2/20187/2/20187/2/2018 9:22:17 AMAPASS
Contractor failed to schedule or follow up
PLM18-02605 Final6/29/20187/2/20187/2/2018 9:21:04 AMAFAIL
Please give our technician Anthony a call when you are on your way so he can let you in (If the door is not open) Phone #: ###-#### Inspection requested via web by Ben Davis.
Install temperature limiting devices/device per ISPC 413.1