Inspections for the day of: Monday, July 2, 2018.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03041 Final6/27/20187/2/20187/2/2018 4:01:38 PMPPASS
INSTALLER ARCHIE ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace ac coil co ok
MEC18-03118 Final6/29/20187/2/20187/2/2018 3:01:49 PMPPASS
Please inspect in the PM. Call on way Brett ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- ac coil co ok
MEC18-02997 Final6/28/20187/2/20187/2/2018 2:35:34 PMPPASS
Please inspect after 2 PM if possible. Saleha Abdul-Khamid ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace co ok
MEC18-03024 Final6/27/20187/2/20187/2/2018 2:05:17 PMPPASS
Please call Kyle to ensure install is complete. ###-#### Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg
- ac coil ok- co ok
MEC18-02124 Final6/28/20187/2/20187/2/2018 1:42:03 PMPFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart- line set has rips that need fixed with tape- line set needs UV protection- ductblast ok- airbalance report ok- Man J. and outdoor unit match
MIS18-00251 MEC-Conference6/29/20187/2/20187/2/2018 12:54:47 PMACANC
monday early afternoon - cancelled Justin didnt answer phone call so i left him a message
MEC18-02464 Final6/29/20187/2/20187/2/2018 12:52:43 PMPPASS
LATE PM ISPECTION IF POSSIBLE PLEASE
THANK YOU Phone #: ###-#### Inspection requested via web by Aaron Alandt- ManJ. ok- duct blast ok- air balance ok- furnace ac coil co ok
MEC18-02716 Final6/28/20187/2/20187/2/2018 11:42:05 AMAPASS
Please call Mary Ellen Kalange prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace ac coil co ok
PLM18-02768 Final7/2/20187/2/20187/2/2018 11:20:49 AMPPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino- water heater final ok
MEC18-02984 Final6/29/20187/2/20187/2/2018 11:07:33 AMAPASS
CAN YOU CALL WHEN YOU ARE ON THE WAY ###-#### CUSTOMERS NAME IS ERIC Phone #: ###-#### Inspection requested via web by Marisa Hone- Furnace ac coil co ok
MEC18-03046 DOC - Permit Finaled7/2/20187/2/20187/2/2018 10:46:15 AMPPASS
fireplace final ok- mantel height ok -gas flex into firplace and shut off valve ok
MEC18-03046 Pressure Test6/29/20187/2/20187/2/2018 10:45:22 AMAPASS
Kathy Stuart Phone #: ###-#### Inspection requested via web by Sheldon Lebow- 20lb gas pressure test ok- R/I ok- final ok
MEC18-02974 Final6/29/20187/2/20187/2/2018 10:29:32 AMAPASS
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 10 AM . Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette- 5lb flue pressure test ok- furnace ac coil co ok
MEC18-02951 Final6/29/20187/2/20187/2/2018 9:42:35 AMAFAIL
please call homeowner Louis when 30 mins in route Phone #: ###-#### Inspection requested via web by Rick Montgomery- gasline needs to be hard piped from manifold out of furnace cabinet cant be flex pipe- need to witness a 5lb flue pressure test- need inert tape on gasline penetration outside
MEC17-05401 Rough-in6/29/20187/2/20187/2/2018 9:17:25 AMAPART
Phone #: ###-#### Inspection requested via web by Nicholas Paige- 1 st floor R/I ok returns are done and insulated- linesets are done and insulated- ok for ceiling tile
MEC17-02006 Mec-Aging Inspection7/2/20187/2/20187/2/2018 8:49:21 AM DONE
called Value Heating and Air they didnt answer so i left a message. Dan called back and said he would work on getting the final scehduled