Inspections for the day of: Thursday, July 20, 2006.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03277 Final7/20/20067/20/20067/20/2006 4:47:22 PMPPASS
stu; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called contr about label and strapping flex, ok to final
ELE05-03276 Final7/20/20067/20/20067/20/2006 3:59:08 PMPPASS
stu; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called contr about label and strapping, ok to final
ELE06-02605 Electrical Rough-In7/20/20067/20/20067/20/2006 3:42:50 PMPPASS
butch - underground (west side) - late afternoon; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to cover west side u/g
ELE06-02637 Temporary Service7/20/20067/20/20067/20/2006 3:05:42 PMPFAIL
sandy ###-#### t/p--re-insp called, left message, left correction notice, NEC 312.5 all conductors entering enclosures shall have abrasion protection, BCC job id sticker shall be posted, correct address shall be posted
ELE06-01395 Final7/20/20067/20/20067/20/2006 2:01:27 PMPNH
ron ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called, left message, no access, left card
ELE06-02694 Permanent Service7/20/20067/20/20067/20/2006 1:05:37 PMPPASS
p/s u/g n ok
ELE06-02694 Electrical Rough-In7/20/20067/20/20067/20/2006 1:04:26 PMPFAIL
mike ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called left corr notice, nec 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 210.52(H) hall from garage shall have a recpt, 210.52(A) wall at top of stairs shall have recpts not over 6' from each other
ELE06-02697 Temporary Service7/20/20067/20/20067/20/2006 12:52:05 PMPFAIL
lynn ###-#### t/p called, left corr notice, nec 408.4 circuit directory shall be provided and be clear, concise, and explicit
ELE06-02665 Rough-In Permanent Service7/20/20067/20/20067/20/2006 11:51:46 AMAFAIL
Scheduled by a contractor via Hello! on 7/20/2006 at 6:51:44 AM. Contact: ###-####. called, left message, nec 300.4(A) edge of holes shall be 1 1/4" from edge of framing members, 210.52(A) there shall be an outlet in 2' wall of kitchen, 334.30 nm cable shall be stapled within 12" of panel, BCC all make-up shall be done, address shall be posted, job id sticker shall be posted,Note, provide ground wire for lv on outside of house
ELE06-02016 Final7/20/20067/20/20067/20/2006 10:45:53 AMAPASS
Scheduled by a contractor via Hello! on 7/20/2006 at 7:03:04 AM. Contact: ###-####. ok to final
ELE06-01270 Final7/19/20067/20/20067/20/2006 10:32:48 AMAPASS
There is no code usually someone there.; Phone #: ###-#### Internet Inspection Request from: William Zerfas ok to final
ELE06-02655 Final7/20/20067/20/20067/20/2006 9:50:36 AMPPASS
see p/s, ok to final
ELE06-02655 Permanent Service7/19/20067/20/20067/20/2006 9:49:01 AMAPASS
Please call my cell with any questions. ###-####. homeowner will be home in morning. Thank you Randy; Phone #: ###-#### Internet Inspection Request from: Randy Fletcher p/s o/h rec ok
ELE06-02662 Final7/20/20067/20/20067/20/2006 9:29:51 AMAPASS
ok to final, see p/s
ELE06-02662 Permanent Service7/19/20067/20/20067/20/2006 9:28:44 AMAPASS
Work performed by Ron Chaney.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz p/s o/h rec ok
ELE06-01755 Final7/19/20067/20/20067/20/2006 9:27:41 AMAPASS
dave; Phone #: ###-#### Internet Inspection Request from: Letitia Gallop ok to final, no card to sign
ELE06-02689 Final7/19/20067/20/20067/20/2006 9:08:25 AMAPASS
any questions please Mike Dale; Phone #: ###-#### Internet Inspection Request from: Jeff Radford ok to final
ELE05-04071 Electrical Rough-In7/19/20067/20/20067/20/2006 8:30:12 AMAPART
Scheduled by a contractor via Hello! on 7/19/2006 at 5:53:59 AM. Contact: ###-####. walls and ceilings only anop ok to cover, corridor 1st fl, ceiling 2nd fl
ELE06-02680 Final7/20/20067/20/20067/20/2006 8:25:57 AMPPASS
ok to final, see p/s
ELE06-02680 Permanent Service7/19/20067/20/20067/20/2006 8:25:12 AMAPASS
craig ###-#### p/s o/h rec ok