ELE05-03277
| Final | 7/20/2006 | 7/20/2006 | 7/20/2006 4:47:22 PM | P | PASS |
|
|
stu; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called contr about label and strapping flex, ok to final
|
ELE05-03276
| Final | 7/20/2006 | 7/20/2006 | 7/20/2006 3:59:08 PM | P | PASS |
|
|
stu; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called contr about label and strapping, ok to final
|
ELE06-02605
| Electrical Rough-In | 7/20/2006 | 7/20/2006 | 7/20/2006 3:42:50 PM | P | PASS |
|
|
butch - underground (west side) - late afternoon; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to cover west side u/g
|
ELE06-02637
| Temporary Service | 7/20/2006 | 7/20/2006 | 7/20/2006 3:05:42 PM | P | FAIL |
|
|
sandy ###-#### t/p--re-insp called, left message, left correction notice, NEC 312.5 all conductors entering enclosures shall have abrasion protection, BCC job id sticker shall be posted, correct address shall be posted
|
ELE06-01395
| Final | 7/20/2006 | 7/20/2006 | 7/20/2006 2:01:27 PM | P | NH |
|
|
ron ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called, left message, no access, left card
|
ELE06-02694
| Permanent Service | 7/20/2006 | 7/20/2006 | 7/20/2006 1:05:37 PM | P | PASS |
|
|
p/s u/g n ok
|
ELE06-02694
| Electrical Rough-In | 7/20/2006 | 7/20/2006 | 7/20/2006 1:04:26 PM | P | FAIL |
|
|
mike ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called left corr notice, nec 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 210.52(H) hall from garage shall have a recpt, 210.52(A) wall at top of stairs shall have recpts not over 6' from each other
|
ELE06-02697
| Temporary Service | 7/20/2006 | 7/20/2006 | 7/20/2006 12:52:05 PM | P | FAIL |
|
|
lynn ###-#### t/p called, left corr notice, nec 408.4 circuit directory shall be provided and be clear, concise, and explicit
|
ELE06-02665
| Rough-In Permanent Service | 7/20/2006 | 7/20/2006 | 7/20/2006 11:51:46 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 7/20/2006 at 6:51:44 AM. Contact: ###-####. called, left message, nec 300.4(A) edge of holes shall be 1 1/4" from edge of framing members, 210.52(A) there shall be an outlet in 2' wall of kitchen, 334.30 nm cable shall be stapled within 12" of panel, BCC all make-up shall be done, address shall be posted, job id sticker shall be posted,Note, provide ground wire for lv on outside of house
|
ELE06-02016
| Final | 7/20/2006 | 7/20/2006 | 7/20/2006 10:45:53 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 7/20/2006 at 7:03:04 AM. Contact: ###-####. ok to final
|
ELE06-01270
| Final | 7/19/2006 | 7/20/2006 | 7/20/2006 10:32:48 AM | A | PASS |
|
|
There is no code usually someone there.; Phone #: ###-#### Internet Inspection Request from: William Zerfas ok to final
|
ELE06-02655
| Final | 7/20/2006 | 7/20/2006 | 7/20/2006 9:50:36 AM | P | PASS |
|
|
see p/s, ok to final
|
ELE06-02655
| Permanent Service | 7/19/2006 | 7/20/2006 | 7/20/2006 9:49:01 AM | A | PASS |
|
|
Please call my cell with any questions. ###-####. homeowner will be home in morning. Thank you Randy; Phone #: ###-#### Internet Inspection Request from: Randy Fletcher p/s o/h rec ok
|
ELE06-02662
| Final | 7/20/2006 | 7/20/2006 | 7/20/2006 9:29:51 AM | A | PASS |
|
|
ok to final, see p/s
|
ELE06-02662
| Permanent Service | 7/19/2006 | 7/20/2006 | 7/20/2006 9:28:44 AM | A | PASS |
|
|
Work performed by Ron Chaney.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz p/s o/h rec ok
|
ELE06-01755
| Final | 7/19/2006 | 7/20/2006 | 7/20/2006 9:27:41 AM | A | PASS |
|
|
dave; Phone #: ###-#### Internet Inspection Request from: Letitia Gallop ok to final, no card to sign
|
ELE06-02689
| Final | 7/19/2006 | 7/20/2006 | 7/20/2006 9:08:25 AM | A | PASS |
|
|
any questions please Mike Dale; Phone #: ###-#### Internet Inspection Request from: Jeff Radford ok to final
|
ELE05-04071
| Electrical Rough-In | 7/19/2006 | 7/20/2006 | 7/20/2006 8:30:12 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 7/19/2006 at 5:53:59 AM. Contact: ###-####. walls and ceilings only anop ok to cover, corridor 1st fl, ceiling 2nd fl
|
ELE06-02680
| Final | 7/20/2006 | 7/20/2006 | 7/20/2006 8:25:57 AM | P | PASS |
|
|
ok to final, see p/s
|
ELE06-02680
| Permanent Service | 7/19/2006 | 7/20/2006 | 7/20/2006 8:25:12 AM | A | PASS |
|
|
craig ###-#### p/s o/h rec ok
|